XR-3 TS2 Module Operation Manual
XR-3
Page 29 of 66
3) Using the PC’s internet browser, access the HughesNet modem setup screens. Ensure that
the OPI display is enabled and display signal strength. The signal strength must be
displayed on the PC to generate the display shown on the meter.
4) Return to the dish and connect the XR-3 into the receiver cable. The XR-3’s ODU / LNB port
should be connected to the LNB and the IDU / IRD port to the modem’s Rx port.
5) Go to the XR-3 OPI/DiSEqC Screen. This screen displays the numbers transmitted from the
modem just like the OPI device.
6) Adjust the dish to peak the transmitter cross-pol quality number. The higher the number, the
better the quality.
DiSEqC Monitoring
When other DiSEqC commands are received on the IDU / IRD port of the meter, they are
displayed on the screen. The most common switch control commands are decoded into switch
type and port selection, other commands may be displayed in their hexadecimal format.
12. Bit Error Rate / Packet Error Rate
The Bit Error Rate / Packet Error Rate screen (select BER from the Main Menu) displays the bit
error rate (BER) or packet error rate (PER) of the signal as detected by the demodulator chipset
within the XR-3’s TS2 module.