INSTALLATION INSTRUCTION
Electrical
Requirement
WARNING
To avoid the risk of property damage,
personal injury or fire, use only copper
conductors.
To avoid property damage, personal injury
or death due to electrical shock, do not use
an extension cord with this unit.
WARNING
To avoid the risk of property damage,
personal injury or fire do not install with
power cord stretched or under a strain as
this may create loose plug/receptacle
connection.
WARNING
To avoid the risk of personal injury, wiring
to the unit must be properly polarized and
grounded.
WARNING
-
5
-
WARNING
HIGH VOLTAGE
Disconnect all power before servicing or
installing this unit multiple power sources
be present , failure to do so may cause
property damage , personal injury or death.
Do not service this unit without first
shutting off the power to the unit form the
circuit breaker and/or removing the unit
cord set plug from the wall outlet.
The power cord is located inside the electrical
control box cover for insert mounting.
LCDI Power
cord
All wiring , including installation of the
receptacle,
must be in accordance with the NEC, CEC and local
codes ordinances and regulations , as applicable.
LCDI
power
Cord
Unit Voltage
Rating
Minimum
Maximum
230/208
187
253
265
238
292
Operating Voltage
Voltage Utilization Range
230
/
208V
15Amp
Perpendicular
230
/
208V
20
Amp
Large tandem
230
/
208V
30Amp
WARNING
To avoid the risk of property damage, personal injury
or death due to fire, ensure that the Case, Unit, and
Front Case Panel are replaced as a complete assembly
in a retrofit/ replacement situation. Do not under any
circumstances insert this Unit into an existing
competitor case. For example, some existing cases
may contain plastics that are incompatible with this
unit from a safety standpoint.
• LCDI Cords
(
230
/
208V
models
only
)-
Underwriters Laboratories and the National Electric
Code (NEC) now require power cords that sense
current leakage and can open the electrical circuit to
the unit on units rated at 250 volts or less. In the event
that unit does not operate, check the reset button
located on or near the head of the power cord as part
of the normal troubleshooting procedure.
•
Cord
connection
to
a
wall
socket
is
not
permitted
for
265V units
.
All
265V
units
must
be
hard
wired
using
the
hard wire
kit.