01
STAINLESS UV
UNVENTED HOT WATER CYLINDERS
PAGE CONTENT
1
Introduction
2
Storage, Handling & Supply Requirements
3
Component
Table
4
Siting the unit
5-6
General Installation
7-8
Discharge Arrangement
9
Technical Specifications: Slimline Direct
10
Technical Specifications: Slimline Indirect
11
Technical Specifications: Direct
12
Technical Specifications: Indirect
13
Technical Specifications: Solar Indirect
14
Solar Coil Installation
15
Solar High Limit
16
S-Plan Wiring Schematics S & Y Plan
17
Pre-Plumbed Wiring Schematics
18
Pump Over run schematic
19
Pre-Plumbed Installation
20-21
Technical Specifications: Pre-Plumbed
22
System Fit Installation
23
Technical Specifications: System Fit
24
Commissioning & Servicing
25
Fault Finding & User Instructions
26
Commissioning
Record
27 - 30
Service History
31- 32
Technical Specification
33-34
Guarantee - Terms & Conditions
35
Gaurantee
INTRODUCTION
The STAINLESS UV Unvented cylinder is made
from Duplex Stainless Steel for excellent corrosion
resistance. STAINLESS UV has a strong rust-proofed
steel case and is highly insulated with environmentally
friendly foam.
STAINLESS UV is supplied complete with all the
necessary safety and control devices needed to
connect to the cold water mains. All are pre-adjusted.
High quality controls have been selected to combine
high flow rate performance with minimum pressure
drop to make STAINLESS UV perform well in all areas,
even those with poor water pressure.
IMPORTANT NOTE TO
THE INSTALLER
Read these instructions before commencing installation.
Unvented cylinders are a controlled service as defined in
the latest edition of the building regulations and should
only be fitted by a competent person.
The relevant regulations are: England and Wales –
Building Regulation G3, Scotland – Technical Standard
P3, N Ireland – Building Regulation Part F
After installation the Benchmark check list must be
completed and left, with these instructions, with the
householder for future reference.
IMPORTANT NOTE TO THE INSTALLER
Read these instructions before commencing installation. Unvented cylinders are a controlled
service as defined in the latest edition of the building regulations and should only be fitted
by a competent person.
The relevant regulations are: England and Wales – Building Regulation G3, Scotland – Technical
Standard P3, N Ireland – Building Regulation Part F
After installation the Benchmark check list must be completed and left, with these
instructions, with the householder for future reference.