CODE
HEIGHT
DIAMETER
A
B
C
D
E
F
ERP BAND
STANDING LOSS (W)
EN120
906
550
290
330
390
345
N/F
N/F
B
47
EN150
1093
550
330
370
465
385
N/F
N/F
B
54
EN180
1281
550
330
370
465
385
N/F
N/F
B
58
EN210
1469
550
365
405
465
465
N/F
1150
C
70
EN250
1719
550
365
405
465
560
950
1400
C
81
EN300
2032
550
365
405
465
660
1100
1600
C
92
25.0˚
40.0˚
45.0˚
35.0˚
15.0˚
50.0˚
10.0˚
All Dimensions are in mm and are of the cased unit.
N/F = not fitted.
22mm COLD FEED WITH
DIP PIPE TO DEFLECTOR
IN BOTTOM OF CYLINDER
22mm SECONDARY
RETURN (not always fitted.
See table)
22mm HOT
DRAW - OFF
“
F PTRV BOSS
1
2
DRY STAT
POCKET
SECOND IMMERSION HEATER
(not always fitted. See table)
F
E
D
C
B
A
STAINLESS UV - INDIRECT
12
STAINLESS UV
UNVENTED HOT WATER CYLINDERS