PV2 Isolation Fault

PV3 Isolation Fault

VDC High

VDC Low

PV Over Current

VAC High

C011

C012

C013

C014

C015

C016

C017

C018

C019

FAC High

VAC Low

FAC Low

Output Current High

EEPROM RW Fault

SCI Fault

Ground I Fault

Inverter Side Relay  Fault

DC Inject Fault

C020

No Grid

C021

C022

C023

C024

C025

Grid Side Relay Fault

Ext comm. Fault

Fan Fault

Inverter Module Temp Fault

Boost inductor Temp Fault

C026

Inverter inductor Temp Fault

Protection Parameters Table

Standards

VDE0126-1-1

Power Grid Volt
Upper Limit

)

(V

Power Grid Volt
Lower Limit (V)

Power Grid Freq.
Upper Limit (Hz)

Power Grid Freq.
Lower Limit (Hz)

EN50438

G83-2

G59-3

RD1699

UTE C15-712-1

AS4777.2/3

CQC

264.5

242

253

253

262.2

262.2

255.3

270

184

187

195.5

184

200.1

200.1

184

200

51.5

50.2

50.5

51

51.5

51.5

50.6

55

47.5

49.5

48

48

47.5

47.5

47.5

45

Code

Status Information

C001

C002

BUS High

Boost Module Temp Fault

C003

Inner Comm Fault

C004

PV1 Isolation Fault

Code

Status Information

Warning Information Table

30/38

PROFESSIONAL

INNOVATIVE    BRANDING

SERVICE

Smart MTL Series 3-Phase Inverter User Manual--Operation Introduction

Summary of Contents for PV17KM3TL

Page 1: ...www apmtech cn Smart MTL Series 3 Phase Inverter User Manual APM TECHNOLOGIES PROFESSIONAL INNOVATIVE BRANDING SERVICE ...

Page 2: ......

Page 3: ...Smart MTL Series 3 Phase Inverter Part NO 18950 293 00 User Manual ...

Page 4: ...ntroduction 5 3 1 PV Grid connected System 5 3 2 Circuit Configuration 5 3 3 Production Description 6 4 Installation 9 4 1 Safety Guidance 9 4 2 Location 9 Selection 4 3 Ambient Conditions 10 4 4 Installation Position 11 4 5 Installation Procedure 11 4 6 Electrical Connection 13 s 4 7 Communication Connection 19 5 LCD Control 23 5 1 LCD Display Panel Introduction 23 5 2 Key Introduction 23 5 3 LED...

Page 5: ... 2 Start Up Procedures 25 7 Operation Introduction 26 7 1 Operation Mode Definition 26 7 2 Initial Power On Menu 27 7 3 Default Main Menu 27 7 4 Main Menu Introduction 27 8 Troubleshooting 36 9 Introduction 37 10 Recycling and Disposal 37 11 Contact 38 Us ...

Page 6: ... outlined in this user manual are suitable for PV17KM3TL PV20KM3TL PV23KM3TL solar inverters Smart stands for flexible and smart and MTL indicates the appliance is without a transformer transformerless and supports for multi channels of MPPT Please read the user manual carefully before using the Smart MTL Series 3 Phase Photovoltaic Grid Connected Inverter in order to ensure correct and safe opera...

Page 7: ...ation 2 minutes Be careful of electric shock and do not touch the appliance in 2 minutes after power off Do not dispose of the product together with the household waste but only in accordance with the locally applicable regulations for the disposal of electronic waste WEEE designation CE marking The inverter complies with the CE requirements Beware of hot surface Beware of dangerous electrical sho...

Page 8: ...hanical knowledge and be familiar with basic electrical and mechanical schematics All materials including but not limited to graphics logos symbols data etc in this manual are owned by the APM Technologies No part of this manual can be reproduced without prior authorization from APM Technologies The content of this manual will continue to be updated and revised as inevitably there are slight discr...

Page 9: ... A B C D E F G H I 1 1 4 1 1 Expansion Bolt 1 1 J 1 K 1 L 6 RS 485 Connector 2 Remarks As ordered For hanging the inverter For fixing the mounting bracket English Version English Version English Version English Version AC Output DC Input Standard English Version Solar Inverter Mounting Bracket User Manual Warranty Card Qualification Card AC Connector Installation Quick Guide DC Connector DC DC Con...

Page 10: ...product delivery please immediately notify the transport company Make sure to take photos documenting the damage to the product and send them to us so that we can provide you with the best service Due to the rather large weight of this solar inverter two or more carriers are required to carry out manual handling operation After taking out the solar inverter from its packaging carton place it corre...

Page 11: ...nal function modules of a Smart MTL Series 3 Phase Photovoltaic Inverter is given below Boosted circuit raises the DC input voltage of PV array to the value required by the solar inverter MPPT ensures the PV array is generating electrical energy with the maximum power Three level inverter circuit will convert the DC power into AC power and the circuit of protection function will monitor the operat...

Page 12: ...Manual Productions Intruduction 6 38 PROFESSIONAL INNOVATIVE BRANDING SERVICE Fan Power DSP1 IGBT Three Level Inverter Circuit DC1 AC Reactor L1 L2 L3 N PE LCD RS485 PV Array DC2 DC3 DC Switch DC EMC Filter MPPT1 Boost MPPT2 Boost MPPT3 Boost DSP2 Relay AC EMC Filter Grid PV Array PV Array DC EMC Filter DC EMC Filter ...

Page 13: ...6 5A 3 6 620V 23000W 200 950V 480 800V 23000W PV23KM3TL 23600W 50Hz 60Hz 1000V 3 16 5A 3 620V 6 3x230V 400V N PE 3x220V 380V N PE 3x230V 400V N PE 3x220V 380V N PE 3x230V 400V N PE 3x220V 380V N PE Max Harmonic Distortion Max output Current 28 3A 33 3A 35A 3 3 3 2 Specifications 0 8 lead 0 8 lag 0 8 lead 0 8 lag 3 3 Max Effeciency 98 20 98 20 98 20 Efficiency Input DC Output AC Smart MTL Series 3 ...

Page 14: ...nication Display Graphical LCD Communication RS485 standard Etherent optional WiFi optional Ambient Parameter Operating Temperture 25 60 Derating from 45 Operation Humidity 0 100 Altitude 2000m Cooling Smart air cooling Protection Level IP65 Mechanism Net Weight 55kg Dimensions WxHxD 529 0x788 0x235 0mm 20 8 x 31 0 x 9 3 inches Noise Index 45dB Safety Isolation Nighttime Loss 0W 0W 0W Transformerl...

Page 15: ...cal standards Because of the solar inverter involves high voltage in its operation external power supply must be cutoff and then waited for at least 120 sec before carrying out any manual oper ation within the inverter s internal compartment Please use a multimeter to measure the DC BUSbar voltage to ensure that the capacitance is being fully self discharge Please note that the temperature of sola...

Page 16: ...ffect the electricity production 3 It is advised not to install the inverter in living quarters since the inverter may produce some operating noise 4 Keep the solar inverter in a place out or reach of children to avoid scalding or electric shock 5 Provide at least a minimum space around any of the solar inverter 250mm 550mm 300mm 300mm 7 Stacked installation mode Smart MTL Series 3 Phase Inverter ...

Page 17: ...hibited to install the inverter obliquely towards one side 5 It is suggested to install the inverter at a mounting height that ke eping the LED screen at the same level with the user s eyes so as to facilitate the ease of operation and data reading 290 0mm 400 0mm Description Please install the solar inverter in a place which is stable and solid enough to bear the dead weight of the inverter for l...

Page 18: ...o drilled holes and then use a rubber hummer to strike the bolts until they are fully inserted into those drilled holes Hang the mounting bracket between the expansion tubes and flat washers and then orderly screw the expansion bolts spring washers and flat washers tightly in a clockwise direction Smart MTL Series 3 Phase Inverter User Manual Installation 12 38 PROFESSIONAL INNOVATIVE BRANDING SER...

Page 19: ...KM3TL PV23KM3TL 4 4 PV17KM3TL 4 When the PV array is directly exposure to sunlight it will generate dangerous DC voltage Please cover the PV array with cloth and then use a multimeter to test and ensure no voltage output from the PV array prior to electrical connection Please select suitable cables according to the cable specifications table Before electrical connection both the AC and DC ports mu...

Page 20: ...n approval from the local power supply department 3 Insert the cable through the nut and socket 4 The cable joint is illustrated as below 8mm 12mm 50mm Cable Joint Socket Fastening Nut Grid L1 wire to the terminal marked 1 Grid L2 wire to the terminal marked 2 Grid L3 wire to the terminal marked 3 Grid Neutral wire to the terminal marked 4 PE wire to the terminal marked Smart MTL Series 3 Phase In...

Page 21: ... a torque of 1 2Nm 7 Finally connect the AC female connector with the AC male connector of solar inverter and a jointing sound is an indication of the connection is in place 8 If the user wanted to remove the AC female connector from solar inverter please do it acc ording to the diagram a below In order to release the cable connector from a socket please do it according to the diagram b DC Switch ...

Page 22: ...of DC side is cutoff Please ensure the voltage of each PV string does not excess 1000 V or the solar inverter is risking an unrecoverable damage 3 The DC end connector includes the following parts 15mm 15mm Must be connected with all the strings of solar inverter It is suggested to connect a 1000 V 25 A circuit breaker on the DC side Smart MTL Series 3 Phase Inverter User Manual Installation 16 38...

Page 23: ...le into the correct tube core position and press the lid until a jointing sound is heard 6 Insert the positive and negative poles of tube cores into the sockets of connectors Smart MTL Series 3 Phase Inverter User Manual Installation 17 38 PROFESSIONAL INNOVATIVE BRANDING SERVICE ...

Page 24: ...a flat blade scr ewdriver into the hole in the middle of connector then push the free end of connector out of the solar inverter For the removing the wire please insert the tip of a flat blade screwdriver into the gap of pressed cover then unclench the pressed cover with the screwdriver to re move the wires from the connector DC Switch ON OFF Smart MTL Series 3 Phase Inverter User Manual Installat...

Page 25: ... for the two communication modes are described below 4 7 Communication Connection It is recommended to use a STP communication cable and please refer to the table below for selection of RS485 communication cable 2 The RS485 communication connector has the parts as shown in below Sealing ring1 Terminal Locker Body Nut 5mm 1 32 1 16 17 32 1 8 9 21 22 32 1 400 400 800 400 800 800 1200 800 1200 800 12...

Page 26: ... tighten the heat shrinkable tube 4 Insert the cable across docking screw seal ring and main part in sequence and ensure the seal ring 1 is screwed into the main part 5 Screw the wire locking nut into the main part of connector and exert an inward force on the locking catch to cause it becoming inward convergence 6 Finally connect the female connector to the male connector of solar inverter and fa...

Page 27: ... status of multiple solar inverters in a PV power generation system please refer to the connection scheme of monitoring system as described below The solar inverter is communicated with a PC through the RS485 RS232 converter and mon itored a single inverter or multiple inverters through a PV system monitoring software 4 7 1 2 Communication Connection of Multiple Inverter T R T R GND VCC RS485B RS4...

Page 28: ...e auxiliary products of APM Technologies you can order them from APM 4 7 2 LAN Communication When a user opts for to the LAN communication it is only needed to connect one end of the cable with solar inverter and connect the other end of cable with a PC RS485 IN 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 120Ω RS485 OUT RS485 IN RS485 IN RS485 OUT RS485 OUT DC Switch ON OFF DC Switch ON OFF Un...

Page 29: ... Up Up Down ENTER ESC RUN FAULT LCD Display 1 0 2 0 4 0 6 0 8 1 0 12 5 20h VDE0126 NONE POWER KW DAY KWh TIME H TOTAL KWh 0 00 0 0 1 3 NORMAL 1 2 3 4 5 6 7 8 2 3 4 5 6 7 8 Current operating status Standard and alternate time display Malfunction information Output power Total generator power of each day Total hours of electricity generation Total power of electricity generation Energy transmission ...

Page 30: ...ly is ON the inspection green indicator interval the LED blinks at an of s and other indicators extinguish 0 25 all LED are ed Normal After self inspect to be normal ion and the solar inverter is used for grid connected power generation the green LED is constantly on LED indicator and other indicators are ed extinguish Fault recoverable Red indicator at interval of 0 5s and other blink an indicato...

Page 31: ...positive and negative polarities in consistence Step 1 Confirm all items in Section 6 1 are meeting the requirements Step 2 Switch ON the external AC circuit breaker Step 3 Switch on the DC Switch Step 4 Observe the LED indicators and LCD screen display for indications of normal operation status If the solar inverter is running normally the green LED indicator is constant on If the red LED indicat...

Page 32: ...tion the inverter will automatically stop to operate the circuit breaker on AC side breaks off and the LCD screen indicating a protection mode The red LED indicator is constant on as well NORMAL Under this condition the solar inverter converts DC current generated by PV array into AC current and transmits the AC current into a power grid The inverter will apply its MPPT function to make the PV arr...

Page 33: ...oduction In the default display interface click the Enter to enter the main menu interface which includes the items ON OFF operation information history record parameter settings and system settings TM www apmtech cn Manually start up and shutdown the solar inverter through the ON OFF sub menu according to the diagram below 7 4 1 ON OFF Sub Menu Smart MTL Series 3 Phase Inverter User Manual Operat...

Page 34: ... using the Down key to turn pages Enter Esc NORMAL VDE0126 NONE POWER ON POWER OFF POWER ON OFF NORMAL VDE0126 NONE YES NO POWER ON Enter Esc Enter Esc Enter Esc NORMAL VDE0126 NONE AC SIDE SYSTEM DATA RUN INFO DC SIDE NORMAL VDE0126 NONE AC SIDE SYSTEM DATA RUN INFO DC SIDE NORMAL VDE0126 NONE AC SIDE SYSTEM DATA RUN INFO DC SIDE NORMAL VDE0126 NONE AC SIDE SYSTEM DATA RUN INFO DC SIDE DC SIDE PV...

Page 35: ...l of the inverter The other protection parameters can be configured through the PROTECT SET found in the PARAMETER SET menu All the information above can be queried through the DOWN key for page turn operation Enter Esc Enter Esc Enter Esc NORMAL VDE0126 NONE WARNING RECORD PROTECTION RECORD RUN INFO STATUS RECORD NORMAL VDE0126 NONE WARNING RECORD PROTECTION RECORD RUN INFO STATUS RECORD NORMAL V...

Page 36: ...t Protection Parameters Table Standards VDE0126 1 1 Power Grid Volt Upper Limit V Power Grid Volt Lower Limit V Power Grid Freq Upper Limit Hz Power Grid Freq Lower Limit Hz EN50438 G83 2 G59 3 RD1699 UTE C15 712 1 AS4777 2 3 CQC 264 5 242 253 253 262 2 262 2 255 3 270 184 187 195 5 184 200 1 200 1 184 200 51 5 50 2 50 5 51 51 5 51 5 50 6 55 47 5 49 5 48 48 47 5 47 5 47 5 45 Code Status Informatio...

Page 37: ...NORMAL VDE0126 NONE LANGUAGE PARA CONTROL COMM SET PROTECT SET PARAMETER SET TIME SET NORMAL VDE0126 NONE LCD BRIGHTNESS INITIAL SET OUTPUT ADJUST DATA CLEAN PARAMETER SET PASSWORD SET NORMAL VDE0126 NONE SYSTEM UPDATE PARAMETER SET Enter Esc NORMAL VDE0126 NONE LANGUAGE PARA CONTROL COMM SET PROTECT SET PARAMETER SET TIME SET NORMAL VDE0126 NONE Z English LANGUAGE Enter Esc NORMAL VDE0126 NONE LA...

Page 38: ...sc NORMAL VDE0126 NONE LANGUAGE PARA CONTROL COMM SET PROTECT SET PARAMETER SET TIME SET MNIP O9PQ 9R STUV WNUV WNIP XY MAC PARA CONTROL Leakage Current Active Island Enable Enable Enable Insulation Resistance Enable LVRT DC Component Enable NORMAL VDE0126 NONE Enter Esc Enter Esc Enter Esc NORMAL VDE0126 NONE LANGUAGE PARA CONTROL COMM SET PROTECT SET PARAMETER SET TIME SET NORMAL VDE0126 NONE Et...

Page 39: ...diagram below The initial password is 000000 7 4 4 7 PASSWORD SET Sub Menu NORMAL VDE0126 NONE LANGUAGE PARA CONTROL COMM SET PROTECT SET PARAMETER SET TIME SET GridMaxVoltage GridMinVoltage V 270 0 200 0 51 50 GridMaxFreq 47 50 GridMinFreq V Hz Hz PROTECTION VDE0126 PROTECT SET NORMAL VDE0126 NONE Enter Esc NORMAL VDE0126 NONE LCD BRIGHTNESS INITIAL SET OUTPUT ADJUST DATA CLEAN PARAMETER SET PASS...

Page 40: ... NO REINITALIZES NORMAL VDE0126 NONE LCD BRIGHTNESS INITIAL SET OUTPUT ADJUST DATA CLEAN PARAMETER SET PASSWORD SET PV 2 Voltage Coefficient PV 3 Voltage Coefficient 100 100 100 PV 1 Current Coefficient 100 PV 2 Current Coefficient PV 1 Voltage Coefficient 100 OUTPUTADJUST NORMAL VDE0126 NONE Enter Esc NORMAL VDE0126 NONE LCD BRIGHTNESS INITIAL SET OUTPUT ADJUST DATA CLEAN PARAMETER SET PASSWORD S...

Page 41: ...TER SET NORMAL VDE0126 NONE CORE UPDATE DISPLAY UPDATE SYSTEM UPDATE NORMAL VDE0126 NONE YES NO Confirm Enter Esc NORMAL VDE0126 NONE POWER ON OFF HISTORY RECORD PARAMETER SET SYSTEM INFO MAIN MENU RUN INFO MODEL PN S N 20KM3TL 0000000000000000 V100R001C01 HUISW V102R001C08 CUSW COMPANY APM SYSTEM INFO NORMAL VDE0126 NONE Smart MTL Series 3 Phase Inverter User Manual Operation Introduction 35 38 P...

Page 42: ...nding protection is indicated Solar inverter will shutdown automatically and restart after the power grid malfunction is solved Red LED indicator blinks no AC output and frequency fault is indicated Inverter will shutdown automatically and restart after the power grid malfunction is solved Red LED indicator blink no AC output and AC over voltage is indicated Inverter will shutdown automatically an...

Page 43: ...ee basis In the case of a product malfunction please contact the nearest retailer distributor dealer or installer to find out about maintenance or replacement of your product Please refer to the warranty card supplied with the product for relevant product warranty terms 10 Recycling and Disposal Do not discard this device and its accessories as solid waste Please contact your local gove rnment age...

Page 44: ...f your questions Below are our contact details APM Technologies 109 Gosun Science Building Nancheng Dongguan Guangdong China Land line 86 769 22028588 Fax 86 769 22026771 Website www apmtech cn E mail mk apmtech cn 11 Contact Us Smart MTL Series 3 Phase Inverter User Manual Contact Us 38 38 PROFESSIONAL INNOVATIVE BRANDING SERVICE ...

Page 45: ......

Page 46: ......

Page 47: ......

Page 48: ...Tel 86 769 2202 8588 E mail MK apmtech cn Fax 86 769 2202 6770 Web www apmtech cn Add 109 Gosun Science Building Nancheng Dongguan City 523000 Guangdong China ...

Reviews: