6. Fasten the fastening nut with a torque of 5 Nm.
5. Use a cross screw driver to loose the screws of each port hole in the cable connector, and
then insert the cable cores into corresponding holes, and tighten the screws again with a
torque of 0.7 Nm. Insert the cable connector into the socket and tighten them with a torque
of 1~2Nm.
7. Finally, connect the AC female connector with the AC male connector of solar inverter, and
a jointing sound is an indication of the connection is in place.
8. If the user wanted to remove the AC female connector from solar inverter, please do it acc-
ording to the diagram a below. In order to release the cable connector from a socket, please
do it according to the diagram b.
+
-
+
-
DC Switch
ON
OFF
+
-
+
-
Smart MTL Series 3-Phase Inverter User Manual--Installation
15/38