![APM PV17KM3TL User Manual Download Page 28](http://html.mh-extra.com/html/apm/pv17km3tl/pv17km3tl_user-manual_2953858028.webp)
Connection Steps
:
1. Connect a 120
termination resistance in series at the first solar inverter.
Ω
2. Connect the RS485 ports of all inverters in a zigzag pattern.
3. Connect the last inverter with a RS485/RS232 converter to enable the communication with
a PC.
The RS485 RS232 converter and monitoring software mentioned above are auxiliary products
/
of APM Technologies, you can order them from APM.
4.7.2 LAN Communication
When a user opts for to the LAN communication, it is only needed to connect one end of the
cable with solar inverter, and connect the other end of cable with a PC.
RS485 IN
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
120Ω
RS485 OUT
RS485 IN
RS485 IN
RS485 OUT
RS485 OUT
+
-
+
-
DC Switch
ON
OFF
+
-
+
-
+
-
+
-
DC Switch
ON
OFF
+
-
+
-
Unit 1
Unit 2
Unit 3
Smart MTL Series 3-Phase Inverter User Manual--Installation