PG5
Rev. A1, 3/10
12
Automation Products Group, Inc.
APG...Providing tailored solutions for measurement applications
Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • [email protected]
• Advanced Settings (AdVSET):
The Advanced Settings menu is used to customize the LCD display and to
setup any optional features, such as an analog output.
Auto-Off (AUTO):
This function is applicable to battery powered units only. The Auto-Off feature
allows the user to designate the time of inactivity (no buttons pushed) until the
gauge automatically powers down.
Options: 2 MIN, 4 MIN, 8 MIN, 16 MIN, 32 MIN and OFF
NOTE:
Selecting OFF disables the Auto-Off feature; the gauge will then remain
powered indefinitely as long as there is sufficient voltage being
supplied (~3.3V).
Setting the Auto-Off feature:
Step 1: Press the On/Off button to enter the main setup menu.
Step 2: Press (Z) to cycle through the menu options until AdVSET is
displayed.
Step 3: Press (S) to enter the Advanced Settings menu.
Step 4: Press (Z) to cycle through the menu options until AUTO is displayed.
Step 5: Press (S) to access the Auto-Off setting options.
Step 6: Press (Z) to cycle through setting options until the desired setting is
displayed.
Step 7: Press (S) to apply the setting and return to main setup menu.