What’s the meaning of the index lights on the panel?
PacMAGIC HEAT PUMP
en
gli
sh
The function of the LED on the panel is showing below:
Index Light
Name
Light
Flash
Temp Setting In the state of temp setting
-
Refrigeration
Refrigerating
Ready to refrigerate, in the state of compressor start delay
protection
Heat
Heating
Ready to heat, in the state of compressor start delay protection
Defrost
Defrosting
Ready to defrost, in the state of compressor start delay protection
Fan
Fan running
-
Alarm
-
Alarm state
The meaning of the LED display
The LED usually shows temperature, if it shows “SHr”, it means the temperature sensor is short, and “OPE” means the tempera-
ture sensor is open. The temperature and the alarm code (Axx) will show alternately when in the alarm state.
The code is showing below:
Code
Signification
Explanation
A11
External alarm
Low Pressure Alarm
A12
External alarm
High Pressure Alarm
A15
External alarm
Water Flow Alarm
A21 Water temperature sensor error Open or short ( showing “OPE” or “SHr” )
A22
Outdoor machine sensor error Open or short ( showing “OPE” or “SHr” when press the key “
↓
”)
A99
Over probation time
If you have set the probation time F87, the alarm occurs when the accumulative
running time is over probation time, and the controller can not work.
35
Summary of Contents for 60298
Page 2: ......
Page 11: ...11 ATTENTION POMPE CHALEUR PacMAGIC fran ais...
Page 29: ...ATTENTION PacMAGIC HEAT PUMP english 29...
Page 47: ...ATENCI N BOMBA DE CALOR PacMAGIC espa ol 47...
Page 65: ...deutsch ACHTUNG 65...
Page 79: ...ERROR syntaxerror OFFENDING COMMAND ztokenexec_continue STACK filestream...