30
8. Start the engine of the power source machine.
9. Allow the power source machine to charge the stalled unit for a few minutes. Start the
engine of the stalled unit.
10. Wait approximately 2 minutes after the stalled unit starts and remove the battery
cables in the reverse order they were installed.
STOPPING THE ENGINE
Severe machine damage can result if the engine is not
properly cooled before shutdown. Allow the engine to
run at idle for at least 5 minutes to allow a gradual
uniform cool down.
Before stopping the engine, perform the following steps:
1. Be sure the slurry pump is turned off and the agitator has stopped spinning.
2. Close all slurry valves.
3. Lower the engine RPM to idle for at least 5 minutes to allow the proper cool down.
4. To stop the engine, rotate the ignition key to the OFF position.