55
CC DIVE OPERATION
Doc. 12-7969 Doc. 12-7969 r09 (9/22/22)
© Apeks (2022)
CONDITIONAL VIOLATION (CV)
Conditional Violation activates when the gradient factor exceeds 90 for less than 5 minutes.
• Credit is not given for off gassing while the gradient factor exceeds 90.
• Operation will revert to Decompression or No Decompression Modes when the gradient factor drops below 90.
• Operation will enter Delayed Violation 1 when the diver exceeds gradient factor 90 for over 5 minutes.
GF>90
DEPTH
DIVE TIME
PO2
1.30
1:06
TTS
0:59
GF
DECO STOP
18
M
-10
MIN
AR
M
16.
1
DELAYED VIOLATION 1 (DV 1)
Delayed Violation 1 activates when the gradient factor exceeds 90 for more than 5 minutes. DV1 is a continua-
tion of CV. DV1 differs from Conditional Violation in that the DSX will enter Violation Gauge Mode 5 minutes after
surfacing. This is regardless of clearing the decompression stops before surfacing.
• Credit is not given for off gassing while the gradient factor exceeds 90.
• Operation will revert to Decompression or No Decompression Modes when the gradient factor drops below 90.
• 5 minutes after surfacing the DSX will enter Violation Gauge Mode.
GF
AR
DEPTH
DIVE TIME
1:06
PO2
1.30
DECO STOP
TTS
18
M
-10
MIN
0:59
GF>90
M
16.
2
GF
AR
DIVE TIME
SURFACE TIME
0:04
1:06
PO2
1.30
DECO STOP
TTS
-10
MIN
-:--
GF>90
18
M
DV1 CC DIVE MAIN
DV1 < 5 MIN ON SURFACE
DELAYED VIOLATION 2 (DV 2)
The DSX will enter Delayed Violation 2 when any single decompression stop exceeds 90 mins or the decompres-
sion ceiling becomes 120 m (400 ft).
• 5 minutes after surfacing the DSX will enter Violation Gauge Mode.
AR
2:37
120
M
-1
MIN
DEPTH
DIVE TIME
2:28
DECO STOP
TTS
GF
PO2
1.30
CC-1 21/00
105
BAR
M
123.
4
AR
3:14
12
M
-93
MIN
DEPTH
DIVE TIME
2:46
DECO STOP
TTS
GF
PO2
1.30
CC-1 21/00
50
BAR
M
117.
9
DECO CEILING DEEPER THAN 120 M
DECO STOP EXCEEDS 90 MIN
Summary of Contents for NS158000
Page 8: ...Doc 12 7969 Doc 12 7969 r09 9 22 22 8 Apeks 2022 GETTING STARTED...
Page 14: ...Doc 12 7969 Doc 12 7969 r09 9 22 22 14 Apeks 2022 DIVE FEATURES...
Page 23: ...Doc 12 7969 Doc 12 7969 r09 9 22 22 23 Apeks 2022 CC CLOSED CIRCUIT SURFACE MODE...
Page 46: ...Doc 12 7969 Doc 12 7969 r09 9 22 22 46 Apeks 2022 CC CLOSED CIRCUIT DIVE OPERATION...
Page 59: ...Doc 12 7969 Doc 12 7969 r09 9 22 22 59 Apeks 2022 OC OPEN CIRCUIT MODE...
Page 65: ...Doc 12 7969 Doc 12 7969 r09 9 22 22 65 Apeks 2022 GAUGE MODE...
Page 68: ...Doc 12 7969 Doc 12 7969 r09 9 22 22 68 Apeks 2022 SM SIDEMOUNT MODES...
Page 73: ...Doc 12 7969 Doc 12 7969 r09 9 22 22 73 Apeks 2022 NAVIGATION...
Page 80: ...Doc 12 7969 Doc 12 7969 r09 9 22 22 80 Apeks 2022 OXYGEN ANALYZER...
Page 87: ...Doc 12 7969 Doc 12 7969 r09 9 22 22 87 Apeks 2022 REFERENCE...
Page 90: ...Doc 12 7969 Doc 12 7969 r09 9 22 22 90 Apeks 2022 TECHNICAL DATA...
Page 96: ...Doc 12 7969 Doc 12 7969 r09 9 22 22 96 Apeks 2022 www apeksdiving com...