![Apantac KVM-SET-14 Manual Download Page 7](http://html1.mh-extra.com/html/apantac/kvm-set-14/kvm-set-14_manual_2951878007.webp)
KVM-SET-14
APANTAC LLC, 10200 SW ALLEN BLVD STE C, BEAVERTON, OR 97005
, TEL: +1 503 968 3000, FAX: +1 503 389 7921
6
5 DC Power Input
DC9 ~ 32V Power input. KVM-IP-Tx-PL is equipped with POE. This is an
optional power input.
6
System LED
(Green) Link LED
(Amber)
Green Blinking/Amber Off: System is starting up.
Green On/Amber Off: System is ready, but TX/RX not connected.
Green On/Amber Blinking: TX/RX connected, but waiting for HDMI input.
Green On/Amber On: TX/RX connected, HDMI input is ready.
7 IR Receiver
Remote Universal IR receiver (optional).
8 RS-232 (Phoenix)
Provides Serial-over-IP function. (Pin assignment: TxD-RxD-GND)
9 Mode button
Short press
Set to Video or Graphic mode.
Long press (3 sec.)
Enable/Disable Anti-Dither.
Note: For some ATI graphic cards
with Dithering function enabled,
enabling Anti-Dither achieves
better video quality.
Press and Hold at Power ON until
Green LED are blinking
Get and Use this RX’s EDID as the
system EDID (update TX EDID)
10 Link button
Short press
To enter Transmitter List OSD
menu, or TX/RX Setting OSD
menu.
Long press (3 sec.)
Gets USB access right.
Press and Hold at Power ON until
Green and Amber LED blinking
1. Reset to the Factory default.
2. Enter Setup and Firmware
upgrade mode in 192.168.0.88
11 USB 1.1 Host
2 USB-A ports for USB 1.1 devices like Keyboard, Mouse, Printer, …
12 USB 2.0 Host
2 USB-A ports for USB 2.0 devices like USB Disk, Touch Screen, …
4.0
Configuraitons
The Tx/Rx units have built-in web pages for Setup and Operation configurations
4.1 Setup Mode
1.
Press and Hold the TX/RX’s [Button 1]/[Link] button and Power ON until Green and Amber LED
blinking then release the button. This will force TX/RX enter Setup mode.
2.
Directly connect TX/RX to PC LAN port, set PC IP to 192.168.0.1, Net Mask 255.255.255.0.
3.
Open PC’s Web Browser (we recommend Chrome) and enter 192.168.0.88 <Enter>
4.
The Setup Mode Web page contains [System] tab with sub-tabs for [Version Information], [Update
Firmware], [Utilities], and [Statistics].
Reset to factory default (Setup Mode)
If the device settings are lost, you can reset the device back to the factory default:
1.
Enter Setup Mode Web page [System] ---> [Utilities] ---> [Factory Default]
(The Factory default settings are shown on the label of the unit)
Firmware Upgrade (Setup Mode)
1.
Enter Setup Mode Web page [System] ---> [Update Firmware] ---> navigate to the firmware file
(.bin) then click [Upload] to start firmware upgrade.
2.
The firmware upgrade takes about 3 minutes, it will display “DONE Rebooting…” to indicate the
unit has been upgraded and rebooted.