background image

Test data under other conditionsare as follows

Ion bar length: 410mm, working frequency: 30Hz

Test distance (mm)

Discharge speed

Positive discharge time 

(S)

Negative discharge time 

(S)

Ion Balance voltage (V)

Vertical

Level

30

-150

1.0

1.7

-13.5

0

0.0

0.0

-6.3

150

2.8

2.7

10.1

50

-150

1.4

3.2

-23.3

0

0.0

0.0

7.5

150

1.8

3.1

-15.8

70

-150

3.0

3.1

17

0

0.1

0.1

13.7

150

2.1

2.3

19.9

100

-150

5.1

4.2

2.75

0

0.5

1.0

9.9

150

6.0

5.4

21.3

Test diagram

30mm

150mm

0s

0s

0.1s

1.0s

1.7s

3.2s

3.1s

5.1s

2.8s

3.1s

2.3s

6.0s

150mm

50mm

70mm

100mm

150mm*150mm Flat tester

Test Conditions

Ion bar length

:4

10mm             Working frequency

30Hz

Test standard: ANSI/ESD.STM3.1, SJ/T 11446—2013
Test instrument: Trek157 static tester
Test voltage: ±1000V → ±100V attenuation
Test environment: humidity 50±5%; temperature 23±3℃

The test data diagram is as follows (test distance: 100mm, ion bar length: 410mm,  working frequency: 30Hz):

Stay away static trouble &

for clean production environment

Efficiently static removal

Summary of Contents for AP-AB1215

Page 1: ...AP TR Shanghai Anping Static Technology Co Ltd High Efficient Electroshock proof Intelligent Ion Bar AP AB1215 AP T...

Page 2: ...nics optoelectronics semiconductor and other industries Effectively solve the problem caused by static electricity Prevent adhesion of objects Static removal Prevent uneven scattering Control ink spla...

Page 3: ...High efficient Safe Static removal...

Page 4: ...e speed HV voltage Positive high Positive voltage working time Negative voltage working time HV Negative high voltage HV Positive high voltage Positive voltage working time Negative voltage working ti...

Page 5: ...o restore the set time The cleaning function becomes invalid if the value is set to 0 days Adjust frequency FREQ Press FREQ first then press to increase or decrease the frequency of positive and negat...

Page 6: ...pressure HV Negative high pressure The pulsed AC method alternately applies and high voltage to one electrode needle to generate two polar ions Compared with the AC method the ion generation efficienc...

Page 7: ...2 2 75 0 0 5 1 0 9 9 150 6 0 5 4 21 3 Test diagram 30mm 150mm 0s 0s 0 1s 1 0s 1 7s 3 2s 3 1s 5 1s 2 8s 3 1s 2 3s 6 0s 150mm 50mm 70mm 100mm 150mm 150mm Flat tester Test Conditions Ion bar length 410m...

Page 8: ...nvironments Electroshock proof Protection against electroshock Working status visualization Red light alarm when high voltage abnormal CE certification It can effectively prevent the external electrom...

Page 9: ...head cross bolt with flat spring pad Ion bar size drawing Mounting bracket size drawing Product Size Product Details Specification Details Parameter Size Negative high voltage orange light on when wo...

Page 10: ...30V AVE Discharge speed 1S Test distance 100mm Status indicator Green light normal Blue light standby Blue light flashing debugging cleaning Red light Abnormal high voltage Working temperature 0 50 W...

Page 11: ...adapter power indicator light is on and the ion bar panel indicator light is green to show that the ion bar is working The positive and negative high voltage indicator lights alternately h with the fr...

Page 12: ...5 200 1 250 Installation position 2 The ion bar grounding electrode is not allowed to be covered by other objects 3 It is advisable to install two ion bars side by side with an interval of more than...

Page 13: ...idden to use this equipment in flammable and explosive environments 5 Unauthorized disassembly of the product is strictly prohibited internal maintenance and repair must be performed by professionals...

Page 14: ...ance index is normal Maintenance NO Faults Reasons Solutions 1 The RJ45 power port indicator on the front panel is off Poor contact of the power cable Power supply mismatch Check whether the power cab...

Page 15: ...g analysis and elimination solution provider Speciality Creates Value AP T Shanghai Anping Static Technology Co Ltd Tel 86 21 64517676 Fax 86 21 64517673 Postcode 200233 Website www ap static com Addr...