background image

AP-AB12

15

 has undergone rigorous testing and aging treatment before ex-work. Its performance has completely reached the 

relevant indicators marked in the usage instruction.

1. AP&T makes a commitment to the customer that any defective parts inspected by AP&T will be repaired or replaced free of charge

within one year from the date of purchase. However, this commitment does not apply to:

(1) The device is incorrectly used or installed.

(2) Damage caused by negligence or accident during use.

(3) Modified, disassembled or repaired by other service departments not authorized by Anping Company.

2. The alloy electrode is a consumable product which is not included in the scope of warranty and will be charged for replacement when

repairing.

3. AP&T shall not be liable for any incorrect use of the products except for repair or replacement of parts as specified above.

After-sales service

1. The ion bar should be cleaned and maintained in time according to the use environment and the required electrostatic protection 

requirements in order to ensure the good performance of the product. That is, gently remove the carbon deposits on the discharge 

electrode, discharge socket, and metal discharge body with electrostatic brush, dust-free cotton swab, dust-free cloth dipped in 

anhydrous alcohol, which will improve its performance significantly. Note:

A. Operation must be done 10 minutes after power cut off.

B. It must be cleaned when dust or white products appear on the tip of the needle during use. Use dust-free cloth dipped in anhydrous 

alcohol to clean when brush can not meet the cleaning requirements.

C. The ion bar must be powered on after alcohol is completely volatilized after cleaning. No other organic solvent can be used to clean 

the ion bar.

2. If the switch working indicator light of the power plug-in port on the panel of the ion bar is off , it should be stopped and repaired by 

professional maintenance personnel. It can be used only after the electrical performance index is normal.

Maintenance

NO.

Faults

Reasons

Solutions

1

The RJ45 power port indicator 

on the front panel is off

Poor contact of the power cable

Power supply mismatch

Check whether the power cable is in good condition and  securely 

connected

Wrong working mode -- Only green light on at the right port (positive 

high voltage only)

Unplug the power cord and restart the ion bar. Or reset the working 

frequency (this lamp is not used to judge the failure of the high 

voltage module)

Wrong working mode -- Only orange light on at the right port (negative 

high voltage only)

The duty ratio is too small and the green light is dark

Adjust duty ratio until ion balance becomes good. Return to factory 

for repair if adjustment is not effective.

The duty ratio is too high and the orange light is dark

2

The electrostatic removal 

performance decreased 

obviously

Discharge needle is polluted and damaged

Clean or replace the discharge needle

Whether the discharge seat is tightened

Confirm the discharge seat is tightened

Ion bar positioning is incorrect

Confirm the best installation location

3

There are conductors or other ion bar around 

4

High voltage alarm

Panel indicator red light 

on 

Electromagnetic interference

Remove (moving) conductors or other ion bar

Abnormal discharge

No power supply for high voltage module

High voltage module is damaged

Return to factory for maintenance

5

Unable to discharge

High voltage module is damaged

Main-board chip is damaged

Return  to  factory  for  maintenance  

Return to factory for maintenance

Main-board chip is damaged caused by poor grounding or no grounding

6

High voltage module is damaged or insulation of the discharge seat is 

damaged

The product is smoky or burnt 

The electrostatic removal

performance decreased

Check the grounding of the ion bar and plant equipment, and return to  

factory for maintenance
Return to factory for maintenance

Confirm the power supply specification

INPUT

100—240VAC 

50/60Hz

OUTPUT

24VDC 2000mA

Turn off the power switch / unplug the power cable, restart the ion bar

Confirm the installation location and stay away from surrounding 

conductors

Return to factory for maintenance

Trouble shooting

Summary of Contents for AP-AB1215

Page 1: ...AP TR Shanghai Anping Static Technology Co Ltd High Efficient Electroshock proof Intelligent Ion Bar AP AB1215 AP T...

Page 2: ...nics optoelectronics semiconductor and other industries Effectively solve the problem caused by static electricity Prevent adhesion of objects Static removal Prevent uneven scattering Control ink spla...

Page 3: ...High efficient Safe Static removal...

Page 4: ...e speed HV voltage Positive high Positive voltage working time Negative voltage working time HV Negative high voltage HV Positive high voltage Positive voltage working time Negative voltage working ti...

Page 5: ...o restore the set time The cleaning function becomes invalid if the value is set to 0 days Adjust frequency FREQ Press FREQ first then press to increase or decrease the frequency of positive and negat...

Page 6: ...pressure HV Negative high pressure The pulsed AC method alternately applies and high voltage to one electrode needle to generate two polar ions Compared with the AC method the ion generation efficienc...

Page 7: ...2 2 75 0 0 5 1 0 9 9 150 6 0 5 4 21 3 Test diagram 30mm 150mm 0s 0s 0 1s 1 0s 1 7s 3 2s 3 1s 5 1s 2 8s 3 1s 2 3s 6 0s 150mm 50mm 70mm 100mm 150mm 150mm Flat tester Test Conditions Ion bar length 410m...

Page 8: ...nvironments Electroshock proof Protection against electroshock Working status visualization Red light alarm when high voltage abnormal CE certification It can effectively prevent the external electrom...

Page 9: ...head cross bolt with flat spring pad Ion bar size drawing Mounting bracket size drawing Product Size Product Details Specification Details Parameter Size Negative high voltage orange light on when wo...

Page 10: ...30V AVE Discharge speed 1S Test distance 100mm Status indicator Green light normal Blue light standby Blue light flashing debugging cleaning Red light Abnormal high voltage Working temperature 0 50 W...

Page 11: ...adapter power indicator light is on and the ion bar panel indicator light is green to show that the ion bar is working The positive and negative high voltage indicator lights alternately h with the fr...

Page 12: ...5 200 1 250 Installation position 2 The ion bar grounding electrode is not allowed to be covered by other objects 3 It is advisable to install two ion bars side by side with an interval of more than...

Page 13: ...idden to use this equipment in flammable and explosive environments 5 Unauthorized disassembly of the product is strictly prohibited internal maintenance and repair must be performed by professionals...

Page 14: ...ance index is normal Maintenance NO Faults Reasons Solutions 1 The RJ45 power port indicator on the front panel is off Poor contact of the power cable Power supply mismatch Check whether the power cab...

Page 15: ...g analysis and elimination solution provider Speciality Creates Value AP T Shanghai Anping Static Technology Co Ltd Tel 86 21 64517676 Fax 86 21 64517673 Postcode 200233 Website www ap static com Addr...

Reviews: