13
Error messages
6.6 Removing the charger
Caution:
First pull the plug out of the socket and observe the sequence for disconnection. This prevents
sparks from forming. Since charging generates a detonating gas, this is particularly important for the sake
of your safety.
Disconnect the charger from the mains power supply. Separate the adapter connection of the charging cable.
Disconnect the pole callipers from the battery, first minus then plus. Allow the battery to cool down.
Only for open batteries:
Fill the cells with distilled water up to the level specified by the battery manufacturer.
Close the battery cells with the stoppers.
7. Maintenance and care
7.1 Maintenance
7.2 Care
Before storing the device, roll up the cables properly using the designated hook in order to prevent damages to the
cables and device. Store the device in a clean and dry place.
8. Notes regarding environmental protection
The packaging is made up of environmentally friendly materials which may be disposed of via your local
recycling points. Do not put electrical devices into the household waste. Electronic and electrical devices
must be collected separately and sent for environmentally friendly recycling. Contact your community or
town administration for information regarding the disposal of electrics.
9. Contact information
Element 1.pdf 1 25.01.19 10:55
EAL GmbH
Otto-Hausmann-Ring 107
42115 Wuppertal, Germany
+49 (0)202 42 92 83 0
+49 (0) 202 42 92 83 – 160
[email protected]
www.eal-vertrieb.com
If used correctly, the device is maintenance-free.
Clean the pole callipers every time the charging procedure is completed. Remove all splashed battery acid from
the pole callipers to prevent corrosion. Clean the device carefully with a dry cloth. Do not use liquids or chemical
cleaning agents. Never submerge the device in liquids. Never allow liquid to flow over the device.
Display of error after faulty connection (wrong poles), short-circuit, selection of an incorrect
charging programme or overheating.
Error message in 6 V – mode, if a battery is connected with less than 5.5 V ± 0.2 or the
voltage is still lower than 6 V after 5 hours of charging time.
In this case, the battery is defective and must be replaced.