background image

20

 

Manufacturer:

 

AOYUE TONGYI ELECTRONIC EQUIPMENT FACTORY 

Jishui Industrial Zone, Nantou, Zhongshan City, 
Guangdong Province, P.R.China 
http://www.aoyue.com

 

DE LUXE REPAIRING SYSTEM 

968A

 

INSTRUCTION MANUAL 

Thank you for purchasing Aoyue 968A+ Repairing System. 

It is important to read the manual before using the unit. 

Please keep manual in accessible place for future reference.

 

CAUTION 

The temperature of the soldering iron, hot air gun and the nozzle ranges from 200 

~ 480 

(400 

~ 850 

F) when the unit is switched ON.  Injury to personnel or damage to items in the 

workplace  may  result  if  not  carefully  used.  Please  read  the  contents  on  how  to  use  the 
equipment and observe the following in order to maximize usage: 

 

After opening the package, check if each  component is in  good working  condition.  If 
there are any suspected damages, do not use the item and report this to the dealer. 

 

Turn  OFF  the  power  switch  and  unplug  the  unit  from  the  main  power  source  when 
moving the equipment to another location. 

 

Do not strike or subject the main unit to any physical shock, including the hot air gun, 
soldering iron or any parts of the system.  Use carefully to avoid damage in any parts. 

 

Make sure the unit is grounded. Always connect power to a grounded receptacle.

 

+

 

aoyue 

®

Summary of Contents for 968A+

Page 1: ...rsonnel or damage to items in the workplace may result if not carefully used Please read the contents on how to use the equipment and observe the following in order to maximize usage After opening the...

Page 2: ...rflow level is noticeably weaker SOLUTION Try to press the Reset button on the panel and let the device re detect the proper operating frequency Note that resetting the device will also reset all prev...

Page 3: ...ading is not increasing or decreasing based on desired level set temperature The panel will then display a blinking OFF on display panels C2 and C3 afterwards SOLUTION The heating element may be broke...

Page 4: ...s Easily adjust temperature offset with a few simple adjustments Intelligent error reporting mechanism Detects and informs the personnel for problems with the sensor and heating element Auto cooling f...

Page 5: ...nt and reconnect the terminal Be careful not to rub or touch together the heating element wire 6 Reconnect the ground wire after replacing the heating element 7 Re assemble the handle NOTE The life ex...

Page 6: ...te temperature when soldering 2 Cleaning Always clean the soldering tip before using Remove any residual solder or flux that are still adhering to the tip Use a clean and moist cleaning sponge to remo...

Page 7: ...error SOLDERING IRON SMOKE ABSORBER 1 Turn on Soldering Iron function and set to desired working temperature Wait for soldering iron to reach set temperature 2 Turn on the Smoke Absorber function swi...

Page 8: ...ration value into the memory 3 Set soldering iron to desired working temperature 4 Wait a few minutes for the temperature to stabilize before checking the temperature difference with an external calib...

Page 9: ...st the calibration number of the soldering iron Turn SMD and Smoke absorber function switch off Turn Soldering iron function switch on Press and hold the hot air temperature increase button A6 9 SMD R...

Page 10: ...A2 will show the current set temperature based on the knob position 11 OPERATING GUIDELINES 5 After a few seconds the digital display A2 will switch to showing the actual temperature You may start sol...

Reviews: