background image

 

 

 Hanging

 

1. OMEGA bracket lamp installed on the hook and tighten the screws 
2. The OMEGA bracket to lamp base, clockwise tightening fast lock  
3. Lamps on each side of a person, lift the fixture, the lamp poles and locking snap hook  
4. The insurance rope through the base hole, and tied to a pole  
 
Installation Notes: 
1.

 

Confirm hook hanging lamps and accessories undamaged and can withstand 10 times the 
total weight of the lamps and cables and accessories, etc.                

2.

 

Note that the lamp lighting the front direction of the bottom body portion of the base 
label                                

3.

 

Installation, maintenance, and mobile lighting should have a stable platform, which 
should have a security fence just below.                                   

4.

 

The insurance insurance rope through the rope hole lamp base, and tied to the lamp housing, 
shall not tied to the handle  

5.

 

Check the lamp housing do not have the range of combustible material within 0.2 meters, 
lamps light beam directed not to be blocked within 10 meters, and the neighborhood do 
not have flammable substances  

6.

 

Check the lamps are not likely to collide with each other at the time of exercise 

7.

 

Check other lamps are not directly irradiated on this fixture, a strong light can damage 
the protective shell lamps  

8.

 

Always make sure when you put the installation being installed in a horizontal plane, 
so as not to slip occurs when the shell running lamps  

 

Power Supply 

                          WARNING: 

              To prevent electric shock, lamp must be grounded, the main power circuit 

breaker must have insurance and switches and ground fault protection 

              Please fixtures directly connected to an AC power source, not connected 

to the silicon box to prevent damage to the lamp  

Power Input 
Lamps internal switching power supply with PFC power supply voltage AC100V-240V 50 / 60Hz

 

Power Connection:  
Plug the power cord has been installed a lighting power connector with mating plug the other 
end should install an appropriate power plug, three-pin plug with grounding. Must follow 
the  manufacturer's  instructions  to  install.  The  following  table  shows  some  plug  pin 
connector recommendations. If you are unsure or have questions, please consult a qualified 
electrician. To power, the power switch should pull to the position "I"。 
  

 
 
 

Summary of Contents for AL120Twins

Page 1: ...Dual Head 2R Moving Head Light AL120Twins USER MANUAL...

Page 2: ...you very much for purchasing this product Before any use please carefully read and fully understand all of this manual recorded safety instructions to avoid potential hazards may cause bodily injury...

Page 3: ...n 6000Hours Color Temperature 8000K DMX control 25 28 38 Channels Pan 540 630 8 16Bit resolution Tilt 270 8 16Bit resolution Pan Tilt infinite rotation Color 13 colors Open Gobos 14 gobos Open Effect...

Page 4: ...er light barrier lenses protective screen or damaged insulation sheet lamps do not use Protective screen on lamps lenses or ultraviolet screens if produce visible damage that damage to the extent of t...

Page 5: ...o not install non original parts not paste any filters on the lens or other optical accessories pictures Do not attempt to short circuit fuse or thermostat switch Avoid falling damage Don t operate al...

Page 6: ...lamps shall be installed on the carrying handle When the lamp is not trustworthy place head of the movement may be driven by the movement of the base Therefore in unacknowledged or hanging lamps firml...

Page 7: ...mable substances 6 Check the lamps are not likely to collide with each other at the time of exercise 7 Check other lamps are not directly irradiated on this fixture a strong light can damage the prote...

Page 8: ...wire 1 Remove the original power cord 2 Clipping about a 1 m long 3 1 5 square specifications for cable 3 The size of the cable by stripping the figure above through the plug end caps and fasteners 4...

Page 9: ...feet and 3 feet of a termination resistor connected across Reliability Tips Use for RS 485 shielded twisted pair design standard microphone cable is not suitable for long distance data transmission ca...

Page 10: ...Low Power Reset Head Reset XY Reset All Reset Channel Auto Test Test Program 1 Test Program 1 Test Program 2 Test Program 2 Test Program 3 Test Program 3 Close Close Option PAN TILT Invert Pan Invert...

Page 11: ...n keys to select 1 to 512 set up after Lighting address code Press MENU to return to the standby screen System settings 1 Mode Standard mode 28 Control channels Reduced mode 25 control channels Extend...

Page 12: ...ys can be set directly 4 Lighting mode Set up bulbs on DMX lighting need controller control lighting the bulb Automatic lighting lighting the lamp will turn on automatically after POST 5 Dimmer mode S...

Page 13: ...44 COLOR 4 45 53 COLOR 5 54 62 COLOR 6 63 71 COLOR 7 72 80 COLOR 8 81 89 COLOR 9 90 98 COLOR 10 99 107 COLOR 11 108 116 COLOR 12 117 127 COLOR 13 128 191 CW ROTATION FAST SLOW 192 255 CCW ROTATION SL...

Page 14: ...O 4 SHAKE 148 154 GOBO 5 SHAKE 155 161 GOBO 6 SHAKE 162 168 GOBO 7 SHAKE 169 175 GOBO 8 SHAKE 176 182 GOBO 9 SHAKE 183 189 GOBO 10 SHAKE 190 196 GOBO 11 SHAKE 197 203 GOBO 12 SHAKE 204 210 GOBO 13 SHA...

Page 15: ...1 15 Left Focus 0 255 Far Near 16 Left Focus 16Bit 0 255 9 12 17 Right Focus 0 255 Far Near 18 Right Focus 16Bit 0 255 10 13 19 Left Frost 0 127 OPEN 128 255 FROST 11 14 20 Right Frost 0 127 OPEN 128...

Page 16: ...92 223 RANDOM STROBE SLOW FAST 224 255 SHUTTER OPEN 20 23 32 Right Dimmer 0 255 Dimmer0 100 33 Right Dimmer 16Bit 0 255 21 24 34 Tilt Run Mode 0 79 TWO TILTS MOVEMENT SEPERATELY 80 159 TWO TILTS WHOLE...

Page 17: ...16 60 79 LAMP OFF 80 120 PAN AND TILT RESET 121 160 HEAD MOTOR RESET 161 255 ALL RESET Route map...

Page 18: ...17...

Page 19: ...rations Optical Coating fragile and easy to scratch the surface You can not use solvents will damage plastic or colored surfaces To maintain proper cooling it is necessary to periodically dust on the...

Page 20: ...19 Aolait lighting CO Ltd No 48 Guanghua Road Xinya Huadu District Guangzhou Tel 86 20 61809262 61809261 Fax 86 20 61809260 E mail sales aolait com Web www aolait com...

Reviews: