Model 32L31F\32L41F
Document No.
ITBC0220
Version
v5.0
Panel K320WD1 series
Effective from
2012-11-1
Date Updated
2012-11-1
NO
Amount
Diagram
Tool Parameters
1
7B11-0405D6-40102111
1
Figure 2
Electric screwdriver
2
Figure 1
3
±
0.5kgfcm
3
7B11-031013-00105111
2
Figure 1
4
5
Prepared by
Reviewed by Approved by
Xu Sijun
Project Controlled Seal
Recent
Modification
Record
2. Install screws by the serial number (install one by one) and abnormalities such as screws being neglected, tilted and slipped are not allowed.
Figure:
Operations and Requirements
Notice
1. Wastes produced by this station shall be placed in the assigned position. Refer to
Waste Classification and Disposal List
.
Fit power cord cover to back cover properly.
Fasten power cord cover to back cover with two
Φ
3
×
10 screws.
When finished, step on the switch with your foot to send the product to
next station.
Ф
4
×
5mm round-head white-zinc-plated machine
screws with jugged washers
(
optional
)
Fasten ground wire of power to the screw hole of panel back plate with
one
Ф
4
×
5mm screw.
Station Name
Power Cord Cover Locking
Section/Serial No. Unit Assembly 20
Part Number
Descriptions
Φ
3
×
10 countersunk-head pointed-tail black-zinc-
plated tapping screws
Please read and understand the
operating instructions carefully
Take only
one screw
at a time
20
Process Requirements:
1. Check for rusted screws, missing
slots or bad cross slot.
2. Check if the electric screwdriver
torque force is within the specified
requirements.
3.When installing screws, align the
electric screwdriver and the screw to
the screw hole vertically (do not tilt).
4. In the process of installing screws,
properly exert pressure to make a
close contact between electric
screwdriver and screw slot to avoid
slipped screw.
5. Put the defective screws in the
defective product box and do not
throw them at will.
1
2
Figure 1