background image

Variable

Description

1

0000

0001

15g

-B281*B02U*CC20  15/17-

2

AWG24

φ

1.5mm

2

AWG24

φ

1.5mm

2

IN(Black), 24VL(Brown), 
0VL(Blue)

IN(Black), 24VL(Brown), 0VL(Blue)

OUT(Black), 24VL(Brown)
OUT(Black), 0VL(Blue)

OUT(Black), 0VL(Blue)

OUT(Black), 24VL(Brown)

AWG26

φ

1.0mm

3

2

3

AWG26

φ

1.0mm

B281SB-02U-CC20
B281SB-02US-CC20
B281PB-02U-CC20
B281PB-02US-CC20
B281XB-02U-CC20

B281XB-02US-CC20

IN

OUT

IN

ALM

OUT

LINK

IN(Black), 24VL(Brown), 0VL(Blue)

2

3

*

 The figure shows an example of B281XB.

IN

OUT

14

38

7.5

200

200

IN

ALM

OUT

LINK

A

B

DP (Red)
DN (Black)

DP (Red)
DN (Black)

Individual specifications

Number of 

occupied points

Detection 
function

Slave unit voltage drop (DP-DN voltage drop)
I/O disconnection 
I/O short-circuit

Weight

Response time

*

4

1ms max.

[Specifications]

[Outside Dimensions]

Transmission specifications

*

4  Indicates the internal processing time of this unit. The maximum transmission delay 

time is defined as “this time + bit transmission cycle time × 2.”

*

5  For input, the above values are assumed when all IN-0VL pins (NPN) or 24VL-IN pins 

(PNP) are short-circuited. 

 

To connect a 3-wire type sensor, add a total current consumption of the sensor.

 

For output, the above values are assumed when all points are turned ON. Add a total 
current consumption of load being connected.

Input side

Transmission side

Specifications of the cable included in ASLINKER

Number of 

core wires Core wire size

Signal name

Core wire sheath 

outer diameter

Number of 

core wires

Core wire size

Signal name

Core wire sheath 

outer diameter

Disconnection 
monitoring function 
setting

I/O disconnection detection and 

short-circuit detection enabled

I/O disconnection detection and 

short-circuit detection disabled

Used to specify whether the I/O cable 
disconnection detecting function is 
enabled or disabled.

[Equipment Parameter and Its Setting]

Equipment

parameter

Setting item 

Description

Factory setting: 0000

Operating ambient temperature/humidity
Storing ambient temperature/humidity
Vibration resistance
Shock resistance
Atmosphere
Operating altitude

*

1

Pollution level

*

2

General specifications

0 – +55°C, 10 – 90%RH No condensation
-25 – +75°C, 10 – 90%RH No condensation
Based on JIS B 3502 and IEC 61131-2
Based on JIS B 3502 and IEC 61131-2
No corrosive gas
0 – 2000m
2 or less

*

1 Do not use or store AnyWireASLINK devices in an environment where the pressure exceeds 

the atmospheric pressure at an altitude of 0 meters. Doing so may result in malfunction.

*

2 “Pollution level” is an index that indicates the degree of occurrence of conductive substances 

in the environment where the device is used.
Pollution level 2 means the occurrence of only pollution by non-conductive substances.
In such an environment, however, electrical conduction could occur due to accidental 
condensation.

B281SB-02U-CC20

B281XB-02U-CC20

B281PB-02U-CC20

B281SB-02US-CC20

B281XB-02US-CC20

B281PB-02US-CC20

NPN bit input: 2 points

NPN bit input: 1 point/

bit output: 1 point

NPN bit output: 2 points

PNP bit input: 2 points

PNP bit input: 1 point/

bit output: 1 point

PNP bit output: 2 points

B281SB-02U-CC20

B281XB-02U-CC20

B281PB-02U-CC20

B281SB-02US-CC20

B281XB-02US-CC20

B281PB-02US-CC20

15.4mA

10.5mA

5.5mA

13.5mA

10.1mA

6.5mA

Transmission side

*

5

(DP-DN)

Current 
consumption

Service power supply voltage

Transmission method

Synchronization method
Transmission procedure
Connection mode

Number of
connection points

*

3

Number of connection units
RAS function

24V DC +15% to -10% (21.6 to 27.6V DC) 
with a ripple of 0.5Vp-p or less
DC power supply superimposed 
total frame/cyclic method
Frame/bit synchronization method
AnyWireASLINK protocol
Bus type  (Multi-drop method, T-branch 
method, Tree branch method)
Number of bit points: 512 points max. 
(Input: 256 bits, Output: 256 bits)
Number of word points: 1024 words max. 
(Input: 512 words, Output: 512 words) 
Up to 128 units
Detection of transmission line disconnection, 
transmission line short-circuit, transmission 
power supply drop, and 
duplicated/unregistered ID

*

3  The number differs depending on the master unit. Be sure to refer to the manual of the 

master unit for the number.

Model

Unit: mm

UL style 2103
2-wire × AWG24 (black) 

φ

4.1

UL style 2844
3-wire × AWG26 (black) 

φ

3.1

UL style 2844
2-wire × AWG26 (black) 

φ

3.1

*

 This figure shows an example 

of the I/O-mixed type terminal.

Summary of Contents for B281-B-02U-CC20 Series

Page 1: ...m safely are indicated as shown below You must observe these precautions Notes on Safety A CAUTION indicates a potentially hazardous situation which if not handled correctly may result in personal inj...

Page 2: ...Lot No About Word Transmission 3 Some products have no indication of function version Year Numbers Lower two digits of the Christian era Month Alphabet as per the table below 19E means May 2019 Single...

Page 3: ...lacement function see the lot No and the manual for the slave unit When a slave unit of a new function version is replaced with that of an old function version the single unit simplified replacement f...

Page 4: ...used in connection to the AnyWireASLINK unit for word transmission Note that this terminal cannot handle word data by setting a word address 5 The single unit simplified replacement function works ev...

Page 5: ...n external power supply How to Connect AnyWireASLINK AnyWireASLINK terminator CAUTION Refer to Table 1 so that the size and length of the transmission line and the allowable supply current lie within...

Page 6: ...resistance suppress the adverse effects of crosstalk caused by transmitted signals and stabilize signals The above filters must be inserted regardless of whether power is supplied to all terminals co...

Page 7: ...all the DP DN 24V and 0V lines run in parallel is more than 50m 24V DC stabilized power supply General purpose power supply filter Use it if necessary 2 wire terminal 2 wire terminal 4 wire terminal 2...

Page 8: ...O connection line I O connection line I O connection line LINK IN0 IN1 ALM Transmission indicator Green Input indicator Orange Input indicator Orange Alarm indicator Red Transmission line connection...

Page 9: ...ay cause a fault of the equipment Black DN Red DP For the power supply to be connected be sure to use a 24V DC stabilized power supply CAUTION AnyWireASLINK master 24V DC Transmission signal Lot No 19...

Page 10: ...t detection are enabled Variable Description Factory setting 0 This parameter is used to specify whether the I O cable disconnection detecting function is enabled or disabled Input When sensor s circu...

Page 11: ...smission signal and power supply are normally connected and the unit is set to the factory set address For S W version A or 3 digit lot No This condition is detected when the master unit executes auto...

Page 12: ...e power supply voltage of an external power source connected to the slave unit I O line so that the power supply voltage does not exceed the rated voltage range 21 6V to 27 6V Make sure that wires of...

Page 13: ...ching current ON current OFF current ON voltage OFF voltage Supply current at 24VL 24V DC 3 5mA 2 2mA or more 1mA or less 16V or more 24VL IN 8V or less 24VL IN 50mA max 24VL 0VL per point 2 wire non...

Page 14: ...mA 2 2mA or more 1mA or less 16V or more IN 0VL 8V or less IN 0VL 50mA max 24VL 0VL per point 2 wire non isolated PNP input B281SB 02US CC20 B281XB 02US CC20 Input To connect inductive load use a surg...

Page 15: ...ution level 2 General specifications 0 55 C 10 90 RH No condensation 25 75 C 10 90 RH No condensation Based on JIS B 3502 and IEC 61131 2 Based on JIS B 3502 and IEC 61131 2 No corrosive gas 0 2000m 2...

Page 16: ...7 5 3 5 5 5 1 5 1 7 R 1 2 23 10 4 3 5 2 4 1 1 2 4 40 2 2 6 15 2 3 5 17 2 10 2 4 4 68 8 17 2 n 1 2 4 B281 B02U CC20 16 17 ADP 81 Mounting adaptor Connection hook Connection hook...

Page 17: ...in Japan 2013 2014 2016 2017 2018 2019 2020 UMA 08717AP EN Anywire Corporation Headquarters 1 Babazusho Nagaokakyo shi Kyoto 617 8550 JAPAN Contact by mail Contact info_e anywire jp Contact by websit...

Reviews: