background image

-B281*B02U*CC20  1/17-

B281

B-02U

-CC20

IN

OUT

IN

ALM

OUT

LINK

B281SB-02U-CC20

B281PB-02U-CC20

B281XB-02U-CC20

B281SB-02US-CC20

B281PB-02US-CC20

B281XB-02US-CC20

ASLINKER

Ver.1.1

[Type]

 Note on use 

A separate Address Writer is required to set addresses and other data.

 *

 For more information, refer to [Various Settings] on page 9.

AnyWireASLINK System Products Guide

NPN input

NPN output

PNP input

PNP output

NPN input/NPN output

PNP input/PNP output

A WARNING indicates a potentially hazardous 

situation which, if not handled correctly, could 

result in death or serious injury.

[Warranty]

 Warranty period

  The warranty on the delivered Product shall continue to be effective for one (1) 

year after the delivery thereof to a location as designated by the original owner.

 Scope of warranty

  Should a defect occur in any part of the Product during the foregoing warranty 

period when it is used normally in accordance with the specifications described 
in this Products Guide, the Company shall replace or repair the defect free of 
charge, except when it arises as a result of:

  [1] Misuse or abuse of the Product by the owner;
  [2] Fault caused by other than the delivered Product;
  [3] The unauthorized modification or repair of the Product by any person other 

than the Company’s personnel;

  [4] Any unusual force of nature, disaster or other cause beyond the Company’s 

control.

  The term “warranty,” as used herein, refers to the warranty applicable to the 

delivered product alone. The Company shall not be liable for consequential or 
incidental damages resulting from any malfunction.

 Repair at cost

  After the expiration of the warranty period, the owner shall be responsible for all 

costs and expenses incurred for the troubleshooting and repair of the Product. 
Even during the warranty term, the Company shall repair any defects arising 
from causes other than within the scope of the warranty as specified above, at 
the owner’s cost.

 Changes in the product specifications and the descriptions in the manual

  The descriptions in this manual may be subject to change without notice.

Precautions that must be observed in order to use this system safely are indicated as shown below. 

You must observe these precautions.

[Notes on Safety]

A CAUTION indicates a potentially hazardous situation 

which, if not handled correctly, may result in personal 

injury or property damage.

 

CAUTION

WARNING

  System power supply

  Use a stable, 24V DC power supply. Use of an unstable power supply may cause problems with the system.

  Separately route high-voltage and power cables

 

Although the AnyWireASLINK has a high noise margin, install the transmission line and I/O cables away from high-voltage and power 
cables.

  Connectors and terminals

- Pay careful attention to the length and installation of cable wiring to ensure that connectors and cables are neither overloaded nor disconnected.
- Make sure to prevent any metal objects from getting inside the connectors or the terminal blocks.
- Short-circuits caused by metal objects or mis-wiring are likely to damage the device.

  Do not impose any external loads on the units. Doing so may cause a failure.

  Do not disconnect or reconnect between the transmission line and slave units when the transmission line is active. A malfunction may occur.

  Use the AnyWireASLINK within the range of the specifications and conditions shown below.

  System Safety

  This system is intended for general industrial applications. It does not have functions for supporting applications requiring higher 

levels of safety such as safety-related devices or accident prevention systems. The product must not be used for these purposes.

  Always turn off the power in installing or replacing the system.

  Prolonged continuous flow of a rated load current or higher or a transit current due to load short-circuit, etc., in the hybrid unit including 

the output unit and the output circuit may result in smoking or firing. An external safety device such as a fuse must be installed.

CAUTION

WARNING

[About Pictogram

*

1

]

Ver. 1.0

*

2

Compatible with

Ver. 1.1

*

3

*

1 The pictogram may not be marked (or stuck) depending on the product.

*

2 AnyWireASLINK device not compatible with Ver. 1.1 (word transmission and 

single unit simplified replacement functions)

 

Some products, not marked with the Ver. 1.1 pictogram, are compatible with 
the functions included in Ver. 1.1. Refer to the lot No. and the product guide 
for ultimate confirmation.

*

3 For details of Ver. 1.1, refer to the subsequent pages.

Summary of Contents for B281-B-02U-CC20 Series

Page 1: ...m safely are indicated as shown below You must observe these precautions Notes on Safety A CAUTION indicates a potentially hazardous situation which if not handled correctly may result in personal inj...

Page 2: ...Lot No About Word Transmission 3 Some products have no indication of function version Year Numbers Lower two digits of the Christian era Month Alphabet as per the table below 19E means May 2019 Single...

Page 3: ...lacement function see the lot No and the manual for the slave unit When a slave unit of a new function version is replaced with that of an old function version the single unit simplified replacement f...

Page 4: ...used in connection to the AnyWireASLINK unit for word transmission Note that this terminal cannot handle word data by setting a word address 5 The single unit simplified replacement function works ev...

Page 5: ...n external power supply How to Connect AnyWireASLINK AnyWireASLINK terminator CAUTION Refer to Table 1 so that the size and length of the transmission line and the allowable supply current lie within...

Page 6: ...resistance suppress the adverse effects of crosstalk caused by transmitted signals and stabilize signals The above filters must be inserted regardless of whether power is supplied to all terminals co...

Page 7: ...all the DP DN 24V and 0V lines run in parallel is more than 50m 24V DC stabilized power supply General purpose power supply filter Use it if necessary 2 wire terminal 2 wire terminal 4 wire terminal 2...

Page 8: ...O connection line I O connection line I O connection line LINK IN0 IN1 ALM Transmission indicator Green Input indicator Orange Input indicator Orange Alarm indicator Red Transmission line connection...

Page 9: ...ay cause a fault of the equipment Black DN Red DP For the power supply to be connected be sure to use a 24V DC stabilized power supply CAUTION AnyWireASLINK master 24V DC Transmission signal Lot No 19...

Page 10: ...t detection are enabled Variable Description Factory setting 0 This parameter is used to specify whether the I O cable disconnection detecting function is enabled or disabled Input When sensor s circu...

Page 11: ...smission signal and power supply are normally connected and the unit is set to the factory set address For S W version A or 3 digit lot No This condition is detected when the master unit executes auto...

Page 12: ...e power supply voltage of an external power source connected to the slave unit I O line so that the power supply voltage does not exceed the rated voltage range 21 6V to 27 6V Make sure that wires of...

Page 13: ...ching current ON current OFF current ON voltage OFF voltage Supply current at 24VL 24V DC 3 5mA 2 2mA or more 1mA or less 16V or more 24VL IN 8V or less 24VL IN 50mA max 24VL 0VL per point 2 wire non...

Page 14: ...mA 2 2mA or more 1mA or less 16V or more IN 0VL 8V or less IN 0VL 50mA max 24VL 0VL per point 2 wire non isolated PNP input B281SB 02US CC20 B281XB 02US CC20 Input To connect inductive load use a surg...

Page 15: ...ution level 2 General specifications 0 55 C 10 90 RH No condensation 25 75 C 10 90 RH No condensation Based on JIS B 3502 and IEC 61131 2 Based on JIS B 3502 and IEC 61131 2 No corrosive gas 0 2000m 2...

Page 16: ...7 5 3 5 5 5 1 5 1 7 R 1 2 23 10 4 3 5 2 4 1 1 2 4 40 2 2 6 15 2 3 5 17 2 10 2 4 4 68 8 17 2 n 1 2 4 B281 B02U CC20 16 17 ADP 81 Mounting adaptor Connection hook Connection hook...

Page 17: ...in Japan 2013 2014 2016 2017 2018 2019 2020 UMA 08717AP EN Anywire Corporation Headquarters 1 Babazusho Nagaokakyo shi Kyoto 617 8550 JAPAN Contact by mail Contact info_e anywire jp Contact by websit...