background image

Anyload Transducer Co. Ltd.

Website: www.anyload.com

Email: [email protected]

Fax: +1 866 612 9088

North America Toll Free: 1-855-ANYLOAD (269 5623)

®

805HP

Handheld Digital Weight Indicator

User’s Manual 

(V1710)

Anyload Transducer Co.Ltd

Website: www.anyload.com
Email: info @ anyload.com

Summary of Contents for 805HP

Page 1: ...ww anyload com Email info anyload com Fax 1 866 612 9088 North America Toll Free 1 855 ANYLOAD 269 5623 805HP Handheld Digital Weight Indicator User s Manual V1710 Anyload Transducer Co Ltd Website www anyload com Email info anyload com ...

Page 2: ...nd panoramic FSTN LCD view angle Material ABS IP Rating Ip65 LCD 6 digit display with LED backlight Non volatile memory for reliable data saving Units of Measurement kg g t lb Klb N kN oz user defined unit Configurable 21 set points for precaution and warning User selectable display interval Overloading recording 10 user selectable analog to digital converting frequency Weight calibration and digi...

Page 3: ...nd panoramic FSTN LCD view angle Material ABS IP Rating Ip65 LCD 6 digit display with LED backlight Non volatile memory for reliable data saving Units of Measurement kg g t lb Klb N kN oz user defined unit Configurable 21 set points for precaution and warning User selectable display interval Overloading recording 10 user selectable analog to digital converting frequency Weight calibration and digi...

Page 4: ...owing page 805HP Battery Power indicator Peak hold mode Weights saved to memory Tare value acquired Gross weight mode Cumulate Mode Scale is zeroed Wireless signal strength Load cell battery power indicator dotted line Weight exceeded the maximum capacity overload warning value signal Signal stability Key Functions Power Button Tare Down key Unit Left key Zero Up key Return key Peak Right key Cumu...

Page 5: ...owing page 805HP Battery Power indicator Peak hold mode Weights saved to memory Tare value acquired Gross weight mode Cumulate Mode Scale is zeroed Wireless signal strength Load cell battery power indicator dotted line Weight exceeded the maximum capacity overload warning value signal Signal stability Key Functions Power Button Tare Down key Unit Left key Zero Up key Return key Peak Right key Cumu...

Page 6: ...o Normal Weighing Mode Go to Peak mode Holding Cancel Clear peak value Long Press 2 sec Short Press 0 5 sec Switch units Switch units Long Press 2 sec Short Press 0 5 sec Gross Net Weight Tare Untare Gross Net Weight TARE CUMULATE ZERO HOLD UNITS Operation mode Power off Operation mode Power saving Function When the indicator is turned off date will be saved in non volatile memory When the indicat...

Page 7: ...o Normal Weighing Mode Go to Peak mode Holding Cancel Clear peak value Long Press 2 sec Short Press 0 5 sec Switch units Switch units Long Press 2 sec Short Press 0 5 sec Gross Net Weight Tare Untare Gross Net Weight TARE CUMULATE ZERO HOLD UNITS Operation mode Power off Operation mode Power saving Function When the indicator is turned off date will be saved in non volatile memory When the indicat...

Page 8: ...er installing the battery long press the on off button for 2 3 seconds then release it The indicator will beep and the screen shows Power off Long press on off button for 2 3 seconds then release it The Ø Ø 6 Start Up and Adjust 6 1 Battery Installation below initialization until reached to indicator weighing system screen shows OFF the indicator is turning off 6 2 Indicator Dimensions 1 1 L H W H...

Page 9: ...er installing the battery long press the on off button for 2 3 seconds then release it The indicator will beep and the screen shows Power off Long press on off button for 2 3 seconds then release it The Ø Ø 6 Start Up and Adjust 6 1 Battery Installation below initialization until reached to indicator weighing system screen shows OFF the indicator is turning off 6 2 Indicator Dimensions 1 1 L H W H...

Page 10: ...orresponding wireless transceiver of a wireless scale Usually 805HP WL wireless model is paired with Anyload 110RH WL TENSLINK scale or 110ES WL Salt Waterproof scale If you need to change the indicator s wireless configurations due to radio frequency interference you can configure the communication parameters with the following steps in Section 9 2 The indicator has three 3 weighing modes namely ...

Page 11: ...orresponding wireless transceiver of a wireless scale Usually 805HP WL wireless model is paired with Anyload 110RH WL TENSLINK scale or 110ES WL Salt Waterproof scale If you need to change the indicator s wireless configurations due to radio frequency interference you can configure the communication parameters with the following steps in Section 9 2 The indicator has three 3 weighing modes namely ...

Page 12: ...k and the accurate When indicator is set to the Normal Weighing mode Peak mark will not Remove the loads from the scale and wait until Stable mark appears The scale should not in Tare mode and Gross weight mark is on Press ZREO and Zero mark appears Zero the scale setting is completed When no Tare is stored Tare mark does not appear Place the load on the scale and wait until Stable mark appears Pr...

Page 13: ...k and the accurate When indicator is set to the Normal Weighing mode Peak mark will not Remove the loads from the scale and wait until Stable mark appears The scale should not in Tare mode and Gross weight mark is on Press ZREO and Zero mark appears Zero the scale setting is completed When no Tare is stored Tare mark does not appear Place the load on the scale and wait until Stable mark appears Pr...

Page 14: ...r when the weight has been tared short press to record the The recently saved weight readings will be displayed in the screen after one second The sign appears in the lower left corner of the screen This means 1 II How to view the cumulative value the middle of the screen Indicator shows as follows peak mode or vice versa III Gross Net Mode vice versa Display shows total gross weight value Gross W...

Page 15: ...r when the weight has been tared short press to record the The recently saved weight readings will be displayed in the screen after one second The sign appears in the lower left corner of the screen This means 1 II How to view the cumulative value the middle of the screen Indicator shows as follows peak mode or vice versa III Gross Net Mode vice versa Display shows total gross weight value Gross W...

Page 16: ...D UNITS Add delete decimal point Level 1 Menu 1 Same as above Level 1 Menu 2 Level 1 Menu N Level 2 Menu 1 Level 2 Menu 2 Level 2 Menu N Parameter 1 Parameter 2 Parameter N Same as above Value 1 Value 2 Value N There are 4 directional keys to be used for the operation are used for horizontal movement in the same level menu and parameters are used for moving up and down through Use to choose a para...

Page 17: ...D UNITS Add delete decimal point Level 1 Menu 1 Same as above Level 1 Menu 2 Level 1 Menu N Level 2 Menu 1 Level 2 Menu 2 Level 2 Menu N Parameter 1 Parameter 2 Parameter N Same as above Value 1 Value 2 Value N There are 4 directional keys to be used for the operation are used for horizontal movement in the same level menu and parameters are used for moving up and down through Use to choose a para...

Page 18: ...ware mode on off related to the software mode on off related to the software mode on off related to the software mode on off related to the software mode on off related to the software mode dis means that the backlight is always on Basic parameter Settings User s unit coefficient Default unit Any Number related to the software mode kg t g lb oz klb N kN UN Overload Warning on off Overload Warning ...

Page 19: ...ware mode on off related to the software mode on off related to the software mode on off related to the software mode on off related to the software mode on off related to the software mode dis means that the backlight is always on Basic parameter Settings User s unit coefficient Default unit Any Number related to the software mode kg t g lb oz klb N kN UN Overload Warning on off Overload Warning ...

Page 20: ...erial com munication on off Baud rate bps 1200 2400 4800 9600 Output DB 8n1 8o1 8e1 Com munication mode Contin reque See note2 See note3 Digit input calibration Standard value Calibration RS232 setting Wireless transmission frequency 2Hz 3Hz 4Hz 5Hz Wireless address 0 255 Any Number Wireless output on off Automatic channel search Manual switching channel 1 16 Wireless gain 1 8 See noet4 Software v...

Page 21: ...erial com munication on off Baud rate bps 1200 2400 4800 9600 Output DB 8n1 8o1 8e1 Com munication mode Contin reque See note2 See note3 Digit input calibration Standard value Calibration RS232 setting Wireless transmission frequency 2Hz 3Hz 4Hz 5Hz Wireless address 0 255 Any Number Wireless output on off Automatic channel search Manual switching channel 1 16 Wireless gain 1 8 See noet4 Software v...

Page 22: ...urn to intermittently overload in the menu 8 3 Modify Password password interface the previous menu Details are as follows 9 Communication The 805HP indicator has two ways in communicating to the scale 9 1 RS232 Communication length is 15 meters and beyond this length may lead to a high error rate I Serial communication baud rate to confirm selection II Data frame format 1 1 1 1 The indicator has ...

Page 23: ...urn to intermittently overload in the menu 8 3 Modify Password password interface the previous menu Details are as follows 9 Communication The 805HP indicator has two ways in communicating to the scale 9 1 RS232 Communication length is 15 meters and beyond this length may lead to a high error rate I Serial communication baud rate to confirm selection II Data frame format 1 1 1 1 The indicator has ...

Page 24: ...is repeatable until Set communication power To set communication power execute command of the menu Press key to select the power level 1 8 press key to perform the set command When the power settings are successful the indicator displays PASS When the power setting fails the indicator displays FAIL Switching command can be executed repeatedly until transceiver too far and if radio frequency interf...

Page 25: ...is repeatable until Set communication power To set communication power execute command of the menu Press key to select the power level 1 8 press key to perform the set command When the power settings are successful the indicator displays PASS When the power setting fails the indicator displays FAIL Switching command can be executed repeatedly until transceiver too far and if radio frequency interf...

Page 26: ...guration menu the indicator shows Remove all loads If hooks or chains are used to hang the test weights load the hooks or chains 2 Press until the indicator shows Press to move into zero A D 3 The indicator shows press to zero calibration The indicator shows the A D count for the zero calibration e g Press again 4 The indicator shows load test weights press The indicator shows the test weight valu...

Page 27: ...guration menu the indicator shows Remove all loads If hooks or chains are used to hang the test weights load the hooks or chains 2 Press until the indicator shows Press to move into zero A D 3 The indicator shows press to zero calibration The indicator shows the A D count for the zero calibration e g Press again 4 The indicator shows load test weights press The indicator shows the test weight valu...

Page 28: ...m without using the actual test weights The method requires the A D count Zero offset value Zero offset can be re corrected when using hooks or chains The following describes calibration procedure for digit calibration methods 2 Press until the indicator shows Press to move into zero A D 3 The indicator shows Press and the indicator will show Press to input the new zero A D count Press again 4 The...

Page 29: ...m without using the actual test weights The method requires the A D count Zero offset value Zero offset can be re corrected when using hooks or chains The following describes calibration procedure for digit calibration methods 2 Press until the indicator shows Press to move into zero A D 3 The indicator shows Press and the indicator will show Press to input the new zero A D count Press again 4 The...

Page 30: ...press input the cor respon ding A D count 11 Troubleshooting Guides 12 Technical Specifications 1 PROBLEM Defective battery Defective button s Power button not properly pressed Digits flash indicator Display does not respond to load changes Low battery Faulty load cell Display weight shows large error Scale is not Zeroed before applying weight Requires recalibration Units kg lb wrong selection See...

Page 31: ...press input the cor respon ding A D count 11 Troubleshooting Guides 12 Technical Specifications 1 PROBLEM Defective battery Defective button s Power button not properly pressed Digits flash indicator Display does not respond to load changes Low battery Faulty load cell Display weight shows large error Scale is not Zeroed before applying weight Requires recalibration Units kg lb wrong selection See...

Page 32: ... t g oz klb N kN are user selectable units Measurements units can be enabled independently and switched The default unit can be selected ABS IP65 RS 232C optional RS 232C optional Functions 21 set points calibration Zero scale Tare Low battery warning Peak hold Power down storage Power saving Date can be saved after power off Date can also be saved after removing batteries If inactive for a period...

Page 33: ... t g oz klb N kN are user selectable units Measurements units can be enabled independently and switched The default unit can be selected ABS IP65 RS 232C optional RS 232C optional Functions 21 set points calibration Zero scale Tare Low battery warning Peak hold Power down storage Power saving Date can be saved after power off Date can also be saved after removing batteries If inactive for a period...

Page 34: ...es 9 7979 Korea Seoul 9 7994 New York 9 8024 Kuwait Kuwait 9 7919 Philadelphia 9 8024 Lebanon Beirut 9 7964 San Francisco 9 7994 Mauritius Port Louis 9 7859 Venezuela Caracas 9 7829 33 ANYLOAD 805HP Handheld Digital Weighing Indicator User s Manual V1710 ANYLOAD 805HP Handheld Digital Weighing Indicator User s Manual V1710 34 13 Appendices 13 1 Seven segment digital display alphanumeric table 13 2...

Page 35: ...es 9 7979 Korea Seoul 9 7994 New York 9 8024 Kuwait Kuwait 9 7919 Philadelphia 9 8024 Lebanon Beirut 9 7964 San Francisco 9 7994 Mauritius Port Louis 9 7859 Venezuela Caracas 9 7829 33 ANYLOAD 805HP Handheld Digital Weighing Indicator User s Manual V1710 ANYLOAD 805HP Handheld Digital Weighing Indicator User s Manual V1710 34 13 Appendices 13 1 Seven segment digital display alphanumeric table 13 2...

Page 36: ...ww anyload com Email info anyload com Fax 1 866 612 9088 North America Toll Free 1 855 ANYLOAD 269 5623 805HP Handheld Digital Weight Indicator User s Manual V1710 Anyload Transducer Co Ltd Website www anyload com Email info anyload com ...

Reviews: