P/N 1010455 Rev. K 10/20
8
Figure 6. Control Programming Sequence
UP
DOWN
PRGM
READY
20
SINGLE SHOT
START/STOP
E. SHO Time in Seconds
UP
DOWN
PRGM
START/STOP
READY
00
SINGLE SHOT
F. SHO Time in Minutes
UP
DOWN
PRGM
START/STOP
READY
1500
SINGLE SHOT
A. Total Cycle Time
UP
DOWN
PRGM
START/STOP
READY
15
SINGLE SHOT
B. Total Cycle Minutes
UP
DOWN
PRGM
START/STOP
READY
H20
SINGLE SHOT
UP
DOWN
PRGM
START/STOP
READY
SINGLE SHOT
G. H2O Cycle
H. H2O Setting
UP
DOWN
PRGM
START/STOP
READY
00
SINGLE SHOT
UP
DOWN
PRGM
START/STOP
READY
SHO
SINGLE SHOT
C. Total Cycle Seconds
D. SHO Cycle
Hi-Limit Reset Button
A hi-limit thermostat turns off electri
-
cal power to the steam generator if it
overheats. To reset this thermostat,
allow approximately 45 minutes for the
unit to cool down, remove the black cap,
and then press the Hi-Limit Reset button
located on the rear of the unit (Figure 7).
If the unit requires continuous resetting,
contact Antunes Technical Service.
Status Indicator LEDs
The Miracle Steamer’s Control Board
has four status indicator LEDs described
below:
Green (Program)
: When lit, indicates the
unit is in Program mode.
Yellow (Audio)
: When lit, indicates 10-
15 VDC is being supplied to the audio
signal. The audio signal sounds and the
LED lights for approximately 3 seconds.
Red (Heat)
: When lit, indicates the
Control Board is calling for heat by
supplying 10-15 VDC to the Solid State
Relay. When off, indicates that the unit is
satisfied.
Green (H2O
): When lit, indicates that
24 VAC is being supplied to operate the
solenoid valve. This LED is only lit for ap-
proximately 1 second.
Fault Codes
When the programming parameters
for Minutes/Seconds/SHO/H2O have
been inadvertently changed below or
above their limits, the unit displays the
“ERR” fault code (Figure 8). If this code
appears, clear these settings using the
procedure below:
1.
Turn the unit off.
2.
Press and hold the Program and
Start/Stop buttons simultaneously
3.
Turn the unit on while continuing to
hold the Program and Start/Stop but-
tons. Release the buttons when the
unit stops beeping,
4.
The display will now register the
cycle time.
NOTE:
Repeat these steps if the unit
still displays the “ERR” fault
code.
NOTE:
It is recommended that the
SHO and H2O settings be
adjusted to the recommended
settings shown in the Pro-
gramming section of this
manual.
READ
Y
Hi-Limit
Reset
Button
Power Cord
Cap
UP
DOWN
PRGM
START/STOP
POWER
READY
ERR
Figure 8. “ERR” Fault Code