Anthony Liftgates, Inc.
12
ETU Maintenance
www.anthonyliftgates.com
800-482-0003
3.5.4 Checking Motor Start Solenoid
Check the motor start solenoid by bypassing the two
terminals.
1. Use automotive jumper cables for this test.
2. Connect one jumper cable to battery side (1) of the
solenoid. Connect the other cable to motor side (2) of
the solenoid.
3. If the liftgate is activated, the solenoid is defective and
should be replaced.
3.5.5 Checking the Power Cable
To check for a defective power cable, run the motor
directly from a spare battery using jumper cables.
1. Remove the battery connection to the motor.
2. Connect the negative jumper cable (ground) directly
to the liftgate. Connect the positive cable to the
terminal on the motor start solenoid.
3. If the motor operates, the battery cable or fuse is
defective and should be replaced.
3.5.6 175 Amp Fuse Replacement
CAUTION
To avoid injury or property damage,
disconnect the liftgate’s power
cable from the battery before
starting to replace the fuse. An”arc” can occur resulting in
personal injury or property damage if the power cable is
connected to the battery.
1. Cut the heat shrink tube to expose the fuse, mounting
hardware, and lugs.
2. Remove the bolt, washer, and lock washer from each
end of the fuse.
3. Use the A-133607, 175 Hi-Amp Fuse Replacement Kit
for the replacement parts.
4. Slide the new heat shrink tube over one side of the
wiring.
5. Bolt the new fuse to the cable lugs using the bolts,
washers, and lock washer, as shown.
6. Slide the heat shrink tube over the fuse, hardware,
and lugs. Using a heat gun apply heat evenly to
shrink the tubing.
7. Reconnect the power cable to the battery after you
are certain liftgate area is clear.
Note:
If the fuse continues to blow, contact your
authorized dealer.