background image

733 E. Eighth St. Suite 103.  Traverse City, MI 49686     Toll Free: 800-819-0095     Fax: 231-933-0091  

[email protected]

 

 

Anthology, Inc. 

 
OPN2001 Rental Scanner and Visual Anthology Physical Inventory 
 

 

Overview: 

 
The OPN2001 series data collectors are small, lightweight, portable barcode 
scanners to use in collecting for your physical inventory.  The data is then 
‘downloaded’ into Anthology via the Physical Inventory module.  These 
scanners are not programmable.   
 

The Physical Inventory module in Anthology was designed so that you can scan 

several batches of books and save each one independently.  This allows you to grab the data from a 
scanner and save it off so you can focus on correcting the batch later on.  This way you can have several 
staff members using scanners, each dumping their scans and moving off to the next batch while one 
person continues to work on reviewing the batches on the computer. 

 

Once you receive these rental scanners, please fill out and fax back the rental agreement immediately.  
You have these scanners for a pre-determined number of days from the time that you receive them. 
 
You should already be using Visual Anthology version 7.4.133 or higher to use the PI module and these 
scanners and have watched the PI training videos available on the Customer Zone.  Additional individual 
store training can be purchased at the discounted rate of $75/hour.  Please note that weekend or after 
hours pager support is not available for Physical Inventory. 
 
For more detailed information on the scanner download the document titled “PI OPN-2001 USB pocket 
scanner User Manual” from the Customer Zone. 
 

 
Connecting the OPN2001 Scanners 

 
A few days in advance to the inventory count, d

ecide which machine will be the ‘central command’ station 

during the PI.  We recommend connecting and preparing the scanners for inventory   This may be the 
main cash register or any other machine that is in a convenient location for all the runners to reach.  This 
machine will have the one and only scanner cable connected to it.  There should only be one person 
using the PI module at the central station, no others may use the PI at the same time. 
 
The OPN2001 scanner comes with a standard USB data connection cable that connects between the 
computer and the scanner (mini connector).   

1.  If you have a Palm device docking unit, a Pole Display, or any other serial based device that is 

connected to COM1 already, shut down the machine, disconnect the device, then power the 
station back on.  This should allow the computer to recognize the device is no longer connected. 

Summary of Contents for OPN2001 Series

Page 1: ...e the PI module and these scanners and have watched the PI training videos available on the Customer Zone Additional individual store training can be purchased at the discounted rate of 75 hour Please...

Page 2: ...the images below to set the correct options and install the necessary driver Note for CLOUD users If you are a Visual Anthology Cloud user be sure to have the scanner and cable connected to the comput...

Page 3: ...18 character string of numbers and letters that is case sensitive Click F12 Post to save 7 This authorization code will allow you to use the rental scanners for a set number of days You will be shown...

Page 4: ...locate any items needing attention If an item has a blank title the scanned barcode was not recognized Either a 12 digit UPC code was mistakenly scanned instead of the EAN ISBN barcode the barcode wa...

Page 5: ...g a batch from any scanner disconnect the scanner close out of anthology wait one minute and try again If the problem persists shut down the computer for 5 full minutes and retry the download To scan...

Page 6: ...PI If you will be doing a Partial PI consider restricting each Master PI record to one section If you must do multiple sections per batch be sure not to reselect the same section twice i e do not att...

Page 7: ...record Simply go to the Master PI record again this is the only record that will have a Status of OPEN This process is called a Manual Update Sort the Master PI record by the section or title or you...

Page 8: ...d a backup cable to try Know that the USB driver will need to be reinstalled if the scanner cable is moved to a different USB port or different computer Q What if I followed all the troubleshooting ti...

Reviews: