background image

Wearable Life Science 

17

9. Care and Maintenance

9.1 Battery Life

•  In case you do not intend to use the BOOSTER for a longer 

  period of time, please make sure to charge it at least every

  six months.

•  Store your BOOSTER in a cool, dry place.

Summary of Contents for CALF-GUARDS

Page 1: ...ANTELOPE CALF GUARDS User Manual...

Page 2: ......

Page 3: ...ANTELOPE CALF GUARDS...

Page 4: ...uctions 2 3 ANTELOPE what is included 4 4 Programs 8 5 Troubleshooting Checklist 9 6 Wearing the Textile 11 7 Warnings and Contraindications 12 8 Further Safety Instructions 15 9 Care and Maintenance...

Page 5: ...Wearable Life Science 10 Disposal 19 11 Guarantee 20 12 Packaging 22 13 Technical Specifications 24 14 Contact 25...

Page 6: ......

Page 7: ...read this manual carefully EMS is a technology scientifically proven to enhance sports performance When you activate a muscle voluntarily your brain sends a signal causing the muscle to contract EMS m...

Page 8: ...cable heads to the buttons placed on the outside of the clothing 3 Plug the other end of the cable into one of the channels of the ANTELOPE BOOSTER 4 Switch on the BOOSTER by holding the button for t...

Page 9: ...uoise in the APP and the LED on the BOOSTER will be blue not blinking 8 Go back and select your favorite training or regeneration program 9 You can adjust the intensity of your workout by either press...

Page 10: ...4 3 ANTELOPE what is included ANTELOPE BOOSTER 2CHANNEL BOOSTER...

Page 11: ...Wearable Life Science 5 ANTELOPE APP Welcome START Let s Go Unleash your potential with ANTELOPE...

Page 12: ...6 ANTELOPE CALF GUARDS...

Page 13: ...Wearable Life Science 7 ANTELOPE CABLE...

Page 14: ...4 Strength 5 Cool Down Active 6 Cool Down Passive 7 Relax 8 Show Your Friends The ANTELOPE APP offers a number of different stimulation programs for various purposes Each of these programs offers a u...

Page 15: ...klist Have you charged your battery It will take about 1 hour to be charged fully Is your charger connected Push the cable into the charger until it clicks into place Is your unit connected to the gar...

Page 16: ...10 Are the electrodes placed correctly Double check if you are wearing the textile properly Please consult the wearing the Textile section p 11 and follow each point as described...

Page 17: ...Wearable Life Science 11 6 Wearing the Textile The ANTELOPE CALF GUARDS should be worn as shown in the illustrations The zipper should be on the front...

Page 18: ...owing points should be taken into account If one or more of these apply to you ANTELOPE products are not safe for health reasons and should not be used Pacemaker or other electrical implants Pregnancy...

Page 19: ...NTELOPE TECHWEAR must not be used after surgical interven tions childbirth laser surgery eyes Please consult a doctor before training with ANTELOPE after such an intervention ATTENTION One possible si...

Page 20: ...workout instructions The following points may indicate serious damage to the muscle tissue rhabdomyolysis If you find yourself displaying one of these symptoms please contact a physician Brown urine M...

Page 21: ...injury Store ANTELOPE products out of the reach of children You must not try to replace the battery pack yourself Opening the BOOSTER yourself may cause damage and will lead to expiry of your guarant...

Page 22: ...e electrodes is washable Your body needs to get used to the kind of stress it is exposed to when using EMS Start at low intensities and slowly increase the power Ensure that you follow the instruction...

Page 23: ...ience 17 9 Care and Maintenance 9 1 Battery Life In case you do not intend to use the BOOSTER for a longer period of time please make sure to charge it at least every six months Store your BOOSTER in...

Page 24: ...ty of the textile please follow these instructions The textile is washable in delicate mode cold water at 40 C To avoid causing damage to the electrodes please do not wash it inside out Use of softene...

Page 25: ...ble Life Science 19 10 Disposal Products carrying the ANTELOPE logo must not be disposed of with your normal household waste Please bring it to a collection point for the recycling of elec tronic equi...

Page 26: ...a one year warranty on electrodes and BOOSTER Excluded from the warranty are Loss destruction of the product due to normal wear and tear fire water damage theft vermin or insect infestation Misuse of...

Page 27: ...Wearable Life Science 21 Faulty installation Wrong maintenance Service or modifications of the device by made by yourself...

Page 28: ...ws By displaying the CE mark the seller confirms that the product complies with all necessary requirements of the EG regulations Conformity assessment procedures were completed as well and the procedu...

Page 29: ...Wearable Life Science 23 Serial Number Batch Number Store in a dry place Warning for critical information find it in the manual...

Page 30: ...rature 0 35 C Humidity 20 85 Operating Conditions Temperature 0 35 C Humidity 20 65 Measurements in mm 105 x 50 x 18 Weight in grams 72g Current Max 100 mA Frequency 1 150 Hz Impulse Width 50 400 s Th...

Page 31: ...Science 25 14 Contact Wearable Life Science GmbH Dr Kurt Schumacher Str 30 90402 Nuremberg Germany Email info antelope club Internet www antelope club Telephone 49 0 69 795 888 95 HRB Nuremberg 30554...

Reviews: