Chapter 5: SERVICE - INFORMATION
Operating manual DC6AT
Page 21 of 28
5. Service – Information
5.1 Parameter overview
Parameters
Function
phys. Range of value resp. choice
1
Type of Drive
2
Software version
3
Hardware version
4/5
Elapsed time counter
6
Status
- No fault
- Under voltage
- Over voltage
- Over temperature
- Processor
7
Instantaneous terminal voltage
8
Instantaneous motor current
9
Electromotive force voltage
10
Int. speed value before integrator
11
Ixt-Value
12
Heat sink temperature
13
Intermediate circuit voltage
14
Current measuring offset
15
Current measuring offset
16
Speed feedback value
30
t off at change of direction
(t
off
)
10ms ... 1s
31
Peak current limit
0 ... 12A
32
Constant current limit
0 ... 6A
33
Motor constant
12,8 ... 64V
34
Current decrease delay
0 ... 8191
35
Motor Resistance
1
0 ... 10
Ω
36
Offset of speed set value
0 ... 10V
37
Multiplier of speed set value
0 ... 3,99
38
Limit over temperature
40 ... 150°C (factory parameter)
39
Limit over voltage
18 ... 80VDC (factory parameter)
40
Acceleration ramp
0,2 ... 10s
41
Reaction after fault
- External Reset (factory parameter)
- Auto Reset
42
P-Behaviour speed controller
1 ... 255
43
I-Behaviour speed controller
0 ... 8191
44
P-Behaviour current controller
1 ... 255
45
I-Behaviour current controller
0 ... 8191
46
Fixed set value n1
0 … 100%
47
Fixed set value n2
0 ... 100%
48
Fixed set value n3
0 ... 100%
49
Function at controller inhibit
- Closed (factory parameter)
- Motor Short Circuit
50
Reserved
51
Reserved
52
Reset behaviour
- Normal (factory parameter)
- Controller ON
53
Reserved
54
Feedback
- IxR (factory parameter)
- pulse
55
Nominal speed
100 … 6000 min
-1
56
Feedback definition
10 … 2000
57
Feedback value filter
0 … 4096
1
Represented all losses in the motor, not only the ohmic winding resistor.