DMX Channel Function
1 Channel Mode
DMX Value Range
Function
Output Level
0
–
4
Off
5
–
255
1
–
100%
3 Channel Mode
DMX Value Range
Function
Output Level
0
–
4
Off
5-255
1
–
100%
Heater
0-126
Off
127-255
On
Pump
0
–
126
Single
127-255
Dual
RDM Control
The M-11 Stage Fogger is RDM enabled, allowing control system to configure, mointor and manage.
See below table for supported RDM parameters
Value
RDM Parameter ID’
s
GET Allowed
SET Allowed
0x0001
DISC_UNIQUE_BRANCH
0x0002
DISC_MUTE
0x0003
DISC_UN_MUTE
0x0030
STATUS_MESSAGE
O
0x0050
SUPPORTED_PARAMETERS
O
0x0051
PARAMETER_DESCRIPTION
O
0x0060
DEVICE_INFO
O
0x0070
PRODUCT_DETAIL_ID_LIST
O