A water collection tray is equipped at the rear of
-200. When the compressor is
DNG
running for condensed fog, some water drops will flow into the tray. Please check the
water level of the tray routinely and drain it on time to prevent overflow. (refer to figure 6).
If the machine is to be used for a long time or the water drops cannot be checked
momentarily, the water collection tray can be removed and a 6 mm
hose can be
PU
connected to the water draining hole located at the top of the water collection tank to
directly drain out the water drops. After completing the draining, push up the upper red
button to remove the hose. (refer to figure 7)
The
-200 is equipped with a pump temperature sensor. When the fog fluid is used
DNG
up in the tank, the pump will stop running due to the rising of the temperature. When the
machine temperature drops down, the pump will resume to run. Please check to see if
the fog fluid is sufficient in the fluid tank.
A black square metal mesh is located at the back of the machine. This is the air inlet of
the fan. Please do not block the inlet and clean it routinely to keep the cleanness.
If the fog volume is too low, the machine generates noise during operation or the fog
cannot be smoothly sprayed, please turn off the power immediately and check if the fog
fluid is sufficient, whether the external fuse, controller connection or power supply has
any problem. If none of the above shows any problem, insert the power plug again. If the
machine still cannot normally operate, please check whether the hose connecting to the
fog fluid tank is blocked, and if any fluid is flowing. If the cause cannot be identified,
please do not allow the machine to operate to avoid damage. Turn off the machine
immediately and let it cool down. Please contact an Antari dealer or a designated
service center. Do not disassemble the machine by yourself.
After using the
-200 for a long time, there may be residue on the floor which could
DNG
be a possible cause of danger. Please note the material of the floor and pay special
attention to the safety of persons walking on it.
The
-200 Low Fog Generator does not use dry ice. It is very environmental friendly
DNG
and safe. However, the output fog is easily to be blown away by wind. Please pay
-Important Notes
D
N
G
-200
User Manual
05
Figure 6
Figure 7
Cleaning your fog machine regularly will help reduce costly replacement and repair
charges.
Do not allow the fog fluid to become contaminated. The cap should be on the tank at all
times.
Prior to storing the machine for a longer period, clean it and drain all fog fluid from the
tank. Disconnect and store the fog pipe and power cord. Store the machine and all parts
into the parts tank located at front of the machine. Warm up the machine once a month,
to protect it from moisture.
Store the machine cool and dry.
-Maintenance of the Machine