30
A.
SHIP'S SERVICE
BATT. SWITCH
300
FUSED, TO PANEL
V. METER
115
3A.
FUSED, TO PANEL
V. METER
114
3A.
AUX.
CHARGE
10A
.
PRIMARY
CHARGE
300
START BATT. SWITCH
MOUNTED STEP FACE
100
A.
309
300
SHIP'S SERVICE.
POS. BUSS
SHIP'S SERVICE.
NEG. BUSS
STBD. START
BATTERY 12V.
BATTERY
COMBINER
SHIP'S SERVICE
BATTERY BANK
4 X 6V.
SOLAR PANELS
PORT ENGINE
SHEET WINCH
HALYARD WINCH
SOLAR PANEL
REGULATOR
STARTER
304
PORT START
BATTERY 12V.
WINDLASS
MAST
JUNCTION
BOX
CIRCUIT PROTECTION
305
301
NEGATIVE CABLES - ga. AS ABOVE
VOLTMETER SENSE - 14 ga.
MAST CIRCUIT NEG. CABLE, 8ga. (310)
SOLAR PANEL FEED - 10 ga.
STBD. ENGINE
30
0A.
NEG.
NEG.
POS.
POS.
NEG.
3A.
3A
.
303
303
POS.
STARTER
NEG.
POS.
STRUCTURAL MEMBERS LT. BLUE
313
30
5
310
START BATT. SWITCH
MOUNTED STEP FACE
302
PANEL SUPPLY
309
307
310
313
FUSED, TO PANEL
V. METER
POS.
307
306
NEG.
FUSED, TO PANEL
V. METER
304
302
302
302
70
A.
70
A.
308
GEN SET
NEG.
GEN. START
BATTERY 12V.
308
POS.
INVERTER / CHARGER
VOLTS
1
1
6
306
117
WINDLASS - 4 ga., 80a. BREAKER
PANEL SUPPLY - 4 ga.
BATT. COMBINER CIRCUITS - 4 ga.
HALYARD WINCH - 4 ga., 70a. BREAKER
SHEET WINCH - 4 ga., 70a. BREAKER
START CIRCUITS - 2 ga.
SHIP'S SERVICE SUPPLY - 2/0 ga.
INVERTER SUPPLY - 2/0 ga., 300a. FUSE
T.C.
ANTARES 44 ELECTRICAL
12V. SUPPLY DISTRIBUTION
EL-04-03
REV. I, MAY 13, 2009
FIRST VESSEL USED 4431
30