background image

Antaira Technologies - Industrial Ethernet Switches

 

 

LNP-0500G-24 Series User Manual V1.0

 

 

 

 

 

FCC Notice

 

 

This equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 

 

15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a 

residential installation. This equipment generates, uses, and can radiate radio frequency energy. It may cause 

harmful interference to radio communications if the equipment is not installed and used in accordance with the 

instructions. However, there is no guarantee that interference will not occur in a particular installation. If this 

equipment does cause harmful interference to radio or television reception, which can be determined by turning 

the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following 

measures: 

 

Reorient or relocate the receiving antenna. 

 

 

Increase the separation between the equipment and receiver. 

 

 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 

 

 

Consult the dealer or an experienced radio/TV technician for help. 

 
 

Caution

: Any changes or modifications not expressly approved by the grantee of this device could void the user's 

authority to operate the equipment. 

 
 

 

CE Mark Warning

 

 

This is a Class-A product. In a domestic environment this product may cause radio interference in which case the 

user may be required to take adequate measures. 

 

 

 
 

 

 
 

Industrial Ethernet Switches

 

 

Industrial Grade Unmanaged Ethernet Switches 

 
 

User Manual 

 

Version 1.0 (October 2015) 

 
 

This manual supports the following models: 

 

 

LNP-0500G-24 

 

 

LNP-0500G-24-T 

 

 

This document is the current official release manual. Please check our website (

www.antaira.com

for any 

updated manual or contact us by e-mail (

[email protected]

). 

Summary of Contents for LNP-0500G-24 Series

Page 1: ...thernet Switches LNP 0500G Series User Manual V1 0 i LNP 0500G 24 Series 5 Port Industrial Gigabit PoE Unmanaged Ethernet Switches with 4 10 100 1000Tx 30W Port 1 10 100 1000Tx 12 36VDC Built in Voltage Booster Version 1 0 User Manual ...

Page 2: ...s Notice Copyrights 2015 by Antaira Technologies LLC All rights reserved Reproduction adaptation or translation without prior permission of Antaira Technologies LLC is prohibited except as allowed under the copyright laws Disclaimer Antaira Technologies LLC provides this manual without warranty of any kind expressed or implied including but not limited to the implied warranties of merchantability ...

Page 3: ...d to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Caution Any changes or modifications not expressl...

Page 4: ... Description 3 2 1 Physical Dimensions 3 2 2 Front Panel 4 2 3 Top View 4 2 4 LED Indicators 5 2 5 Ethernet Ports 5 2 6 Cabling 7 2 7 Wiring the Power Inputs 7 2 8 Wiring the Fault Alarm Contact 8 3 Mounting Installation 9 3 1 DIN Rail Mounting 9 3 2 Wall Mounting 11 4 Hardware Installation 12 4 1 Installation Steps 12 5 Network Application 13 6 Trouble Shooting 14 7 Technical Specifications 15 ...

Page 5: ...nst any unregulated voltage This product series provides a reliable hardened Ethernet connection with PoE functions for any outdoor or harsh industrial application environment such as security surveillance ITS traffic monitoring systems oil gas and mining facility management for power utility water wastewater treatment plants and lastly automated production lines in factory automation 1 1 Key Feat...

Page 6: ...00Tx 30W port and 1 10 100 1000Tx 1 Product CD 2 Wall mounting brackets and screws 1 DC cable 18 AWG DC jack 5 5x2 1mm 1 3 Safety Precaution Attention If the DC voltage is supplied by an external circuit please use a protection device on the power supply input The industrial Ethernet switch s hardware specs ports cabling information and wiring installation will be described within this user manual...

Page 7: ...tion 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of Antaira Technologies LNP 0500G 24 series 5 port industrial Gigabit PoE unmanaged Ethernet switch with 4 10 100 1000Tx 30W port and 1 10 100 1000Tx W x D x H is 46mm x 99mm x 142mm Figure 2 1 LNP 0500G 24 Series Physical Dimensions ...

Page 8: ...minal Block Power Input Grounding Screw LED for PWR1 PWR2 and Fault LAN Port 5 10 100 1000Tx LED for 1000Tx network speed status LAN Port 1 4 10 100Tx LED for 10 100Tx network speed Status LED for PoE Status Figure 2 2 Front Panel of the LNP 0500G 24 Series 2 3 Top View Figure 2 3 below shows the top panel of the LNP 0500G series switch that is equipped with one 6 pin removal terminal block connec...

Page 9: ... power to the powered device Off No powered device attached or power supplying fails LNK ACT SFP Port Green On Connected to network Flashing Networking is active Off Not connected to network LAN Port 1 5 Left LED Green On Connected to network 1000Mbps Flashing Networking is active Off Not connected to network LAN Port 1 5 Right LED Green On Connected to network 100Mbps 10Mbps Flashing Networking i...

Page 10: ...or hubs With straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable The table below Table 2 3 shows the 10BASE T 100BASE TX 1000BASE T MDI port pin outs Pin MDI X Signal Name MDI Signal Name 1 Receive Data plus RD Transmit Data plus TD 2 Receive Data minus RD Transmit Data minus TD 3 Transmit Data plus TD Rec...

Page 11: ...tation etc must be less than 100 meters 328 ft long 2 7 Wiring the Power Inputs Please follow the below steps to insert the power wire 1 Insert the positive and negative wires into the PWR1 V1 V1 and PWR2 V2 V2 contacts on the terminal block connector as shown below in Figure 2 6 Figure 2 6 Power Terminal Block 2 Tighten the wire clamp screws to prevent the wires from loosening as shown below in F...

Page 12: ...igure 2 8 By inserting the wires it will detect the fault status including power failure or port link failure managed industrial switch only and form a normal open circuit An example is shown below in Figure 2 8 Figure 2 8 Wiring the Fault Alarm Contact Note The wire gauge for the terminal block should range between 12 24 AWG If only using one power source jumper Pin 1 to Pin 5 and Pin 2 to Pin 6 ...

Page 13: ...allation 3 1 DIN Rail Mounting The DIN Rail is pre installed on the industrial Ethernet switch from the factory If the DIN Rail is not on the industrial Ethernet switch please refer to Figure 3 1 to learn how to install the DIN Rail on the switch Figure 3 1 The Rear Side of the Switch and DIN Rail Bracket ...

Page 14: ...racket do the opposite from step 1 3 After the DIN Rail bracket is installed on the rear side of the switch insert the top of the DIN Rail on to the track as shown below in Figure 3 2 Figure 3 2 Insert the Switch on the DIN Rail 4 Lightly pull down the bracket on to the rail as shown below in Figure 3 3 Figure 3 3 Stable the Switch on DIN Rail 5 Check if the bracket is mounted tightly on the rail ...

Page 15: ...Place the wall mounting brackets on the top and bottom of the industrial Ethernet switch 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch 4 Use the hook holes at the corners of the wall mounting bracket to hang the industrial Ethernet switch on the wall 5 To remove the wall mount bracket do the opposite from the steps above Figure 3 4 Remove DIN Rail Bracket fr...

Page 16: ...g section for wall mounting installation 3 To hang the industrial Ethernet switch on a DIN Rail or wall please refer to the Mounting Installation section 4 Power on the industrial Ethernet switch and then the power LED light will turn on For the help on how to wire power please refer to the Wiring the Power Inputs section Please refer to the LED Indicators section for LED light indication 5 Prepar...

Page 17: ...ies Industrial Ethernet Switches LNP 0500G 24 Series User Manual V1 0 5 Network Application This segment provides an example of an industrial Ethernet switch application Figure 5 1 Figure 5 1 Networking Application Example ...

Page 18: ...00 meters 328 feet Diagnosing LED Indicators To assist in identifying problems the switch can be easily monitored with the LED indicators which help to identity if any problems exist o Please refer to the LED Indicators section for LED light indication If the power indicator LED does not turn on when the power cord is plugged in the user may have a problem with the power cord Check for loose power...

Page 19: ...speed full half duplex mode and auto MDI connection PoE Pin Assignment V V V V for pin 1 2 3 6 Endspan MDI Alternative A LED Indicator Per unit Power1 Green Power2 Green Fault Red Per port Link Activity Green PoE Feeding Power Green Network Cable 10BaseT 2 pair UTP STP Cat 3 4 5 cable EIA TIA 568 100 ohm 100m 100BaseTX 2 pair UTP STP Cat 5 cable EIA TIA 568 100 ohm 100m 1000BaseTX UTP STP Cat 5 5E...

Page 20: ...e 7 1 LNP 0500G 24 Series Technical Specifications Antaira Customer Service and Support Antaira US Headquarter 844 268 2472 Antaira Europe Office 48 22 862 88 81 Antaira Asia Office 886 2 2218 9733 Please report any problems to Antaira www antaira com support antaira com www antaira eu info antaira eu www antaira com tw info antaira com tw Any changes to this material will be announced on the Anta...