2.6 Cabling
Twisted-pair segments can be connected with an unshielded twisted pair (UTP) or shielded
twisted pair (STP) cable. The cable must comply with the IEEE 802.3u 100Base TX standard
(e.g. Category 5, 5e, or 6). The cable between the equipment and the link partner (switch,
hub, workstation, etc.) must be less than 100 meters (328 ft.) long.
2.7 Wiring the Power Inputs
Please follow the below steps to insert the power wire.
1. Insert the positive and negative wires into the PWR1 (V1+, V1-) and PW R2 (V2+, V2-)
contacts on the terminal block connector as shown below in
Figure 2.6
.
Figure 2.6
Power Terminal Block
2. Tighten the wire-clamp screws to prevent the wires from loosening, as shown below in
Figure
2.7
.
Figure 2.7
Power Terminal Block
**Note:
Only use copper conductors,
60/75
°
C
, tighten to
5 lbs.
The wire gauge for the terminal block should range between
18~20 AWG
.