G.FIT User Guide and Specification, Rev 2.0_Alpha.14
Page 69 of 117
thisisant.
com
7.3.14
fe_command_product_info (0xE4)
Set Data Command: Update the product information transmitted over the ANT+ data pages 80 and 81 (known
as common data pages), and over the BLE Device Information Service and advertising packets.
Valid State: OFF
Table 7-36. fe_command_product_info command message
Byte #
Name
Length
Description
0
Sync
1 byte
Fixed value of 10100100 or 10100101
(Refer to the
Interfacing with ANT General Purpose Chipsets and
Modules document for details.)
1
Length
1 byte
Variable - Set to 0x02 + Product Information Value Length. See
Table 7-38.
2
Message ID
1 byte
Set to 0xE2 (command)
3
Sub-Message ID
1 byte
Set to 0xE4 (fe_command_product_info)
4-(N-1)
Payload
Variable
Byte 4
–
Table 7-38.
Byte 5
–
(N-1)
–
Product Information Value. See
N
Checksum
1 byte
XOR of all previous bytes including the sync byte.
Table 7-37. fe_command_product_info response message
Byte #
Name
Length
Description
0
Sync
1 byte
Fixed value of 10100100 or 10100101
(Refer to the
Interfacing with ANT General Purpose Chipsets and
Modules document for details.)
1
Length
1 byte
0x05
2
Response ID
2 bytes
0xE0 (response)
3
0xFE (G.FIT response)
4
Command ID
2 bytes
0xE2 (command)
5
0xE4 (fe_command_product_info)
6
Response Code
1 byte
0x00 - GFIT_SUCCESS
0x01 - GFIT_ERROR_INCORRECT_STATE
0x07
–
GFIT_ERROR_INVALID_PARAMETER
0x12 - GFIT_ERROR_INVALID_LENGTH
See Table 7-1 for descriptions.
7
Payload
1 byte
Current State:
0x00
–
State is INVALID
0x01
–
State is OFF
0x02
–
State is READY
0x03
–
State is IN USE
0x04
–
State is PAUSED/FINISHED
8
Checksum
1 byte
XOR of all previous bytes including the sync byte.