SAFETY INSTRUCTIONS

Read the User Instructions carefully before use 

Please retain for future reference.

•  This appliance can be used by children aged from 8 years and above and 

people with reduced physical, sensory or mental capabilities or lack of 
experience and knowledge if they have been given supervision or instruction 
concerning use of the appliance in a safe way and understand the hazards 
involved. Children shall not play with the appliance. Cleaning and user 
maintenance shall not be made by children without supervision.

•  Keep the appliance and its cord out of reach of children less than 8 years.
•  This convector fan can be used with heating and ventilation systems in public 

and private buildings as well as in residential homes.

•  The convector fan should be installed, tested and maintained by a technician 

with a good understanding of national regulations and experience with this 
kind of product.

•  Check that the fan’s rated voltage (located on the type plate) is in accordance 

with the  
building’s electrical system before initiating connection as per the wiring 
diagram.

•  The convector fan must be earthed in order to avoid dangerous situations in 

the case  
of defective insulation.

•  Check that the fan has been turned off before beginning installation or 

maintenance.

•  The fan may not be used in environments where inflammable substances are 

present or positioned where there is a major risk of corrosion.

•  Remove the plug when the fan is not going to be used for some time. 
•  Check that the fan’s air intake and air outlet are unobstructed and clear of 

blockages.

Operating instructions for  
fan convector

ENGLISH

Summary of Contents for 416-115

Page 1: ...Bruksanvisning f r fl ktkonvektor Bruksanvisning for viftekonvektor Instrukcja obs ugi klimakonwektora User Instructions for fan convector 416 115...

Page 2: ...inal instructions Jula reserves the right to make changes In the event of problems please contact our service department www jula com NO Bruksanvisning Oversettelse av original bruksanvisning Med forb...

Page 3: ...station e g the local authority s recycling station Verne om milj et M ikke kastes sammen med husholdningsavfallet Dette produktet m inneholder elekt riske eller elektroniske komponentersom skal gjenv...

Page 4: ...kontrollen 14 FELS KNING 20 Felkoder 20 Orsaker och avhj lpning 21 UNDERH LL 23 KOPPLINGSSCHEMA 24 NORSK 26 SIKKERHETSANVISNINGER 26 TEKNISKE DATA 27 BESKRIVELSE 28 Funksjon 28 MONTERING 29 Plassering...

Page 5: ...USTEREK 60 Kody b d w 60 Przyczyna i spos b usuni cia 61 KONSERWACJA 63 SCHEMAT PO CZE 64 ENGLISH 66 SAFETY INSTRUCTIONS 66 TECHNICAL DATA 67 DESCRIPTION 68 Working Principles 68 ASSEMBLY 69 Positioni...

Page 6: ...ed v rme och ventilationssystem i offentliga och privata byggnader samt bostadshus Konvektorfl kten b r installeras provk ras och underh llas av en fackman med god k nnedom om nationella regelverk sam...

Page 7: ...Temperaturomr de 5 70 C Luftfl de v rme 750 m h Ljudniv 35 dB Vattenanslutning G3 8 Energiklass A Sp nning 230 v M tt B89 x H28 x D21 cm Vikt 12 kg V rmeeffekten r angiven vid lufttemperartur 20 C vat...

Page 8: ...mmet Anv nds kallvatten st ll in fl kten p kyla f r att g ra rummet svalare Anv nds varmvatten st ll in fl kten p v rme f r att g ra rummet varmare Denna p litliga konvektorfl kt sparar energi r mycke...

Page 9: ...TE OBS Om v rme och ventilationssystemet r placerat inomhus och avloppsslangen kan anslutas till det befintliga avloppssystemet beh vs inget h l tas upp i v ggen I detta fall kan r ren f r b de in och...

Page 10: ...g till v nster eller h ger om fl kten H let ska ha ett litet fall mot utomhussidan bild 2 och 3 5 Kontrollera vilka f reskrifter som g ller f r r rgenomf ring i ytterv ggar Kr vs genomf ringshylsa se...

Page 11: ...m tjockt bild 6 Kontrollera ocks att r risoleringen verensst mmer med nationella f reskrifter D lig isolering kan leda till f rs mrad effektivitet OBS R risoleringen ska omsluta b de in och utg ende r...

Page 12: ...vatten till VVS systemet Kontrollera att t tningarna r korrekt monterade OBS Ingen del av avloppsslangen f r befinna sig p h gre niv n fl kten LUFTNING Efter att ha kopplat in vattenr r och avloppssl...

Page 13: ...ventilen genom att skruva upp den f r hand eller med en platt ng bild 12 4 ppna ventilen f r inloppsvattnet s att vattnet rinner in i fl kten Kontrollera att du ser vatten i den genomskinliga slang so...

Page 14: ...n 6 Timer P Startar timern 7 Fl kt Anv nds f r att v lja fl kthastighet auto l g medel h g 8 Timmar och minuter Anv nds f r att st lla in klocka och timer 9 Lodr ta fl ktlameller Anv nds f r att regle...

Page 15: ...a rumstemperaturen med den nskade temperatur som st llts in med fj rrkontrollen och baserat p detta startas antingen kylning eller uppv rmning N r nskad temperatur r inst lld f r uppv rmning eller kyl...

Page 16: ...erna Valt l ge visas p fj rrkontrollens display V rme Temperaturen kan st llas in p 16 31 C Grundinst llningen r 27 C Vid val av v rme kan det dr ja en stund innan fl kten startar i och med att restky...

Page 17: ...as fl kten och timerfunktionen st ngs av St lla in stopptiden bild 14 Anv nd knappen f r att st lla in stopptiden Tryck f rst p Anv nd sedan knapparna HR och MIN f r att st lla in tiden d du vill att...

Page 18: ...a nattl get Symbolen visas p displayen Under nattl get h js s nks temperaturen med en grad varannan timme beroende p om v rme eller kyla valts N r temperaturen ndrats 3 C anv nds den d aktuella temper...

Page 19: ...astigheterna Vald hastighet visas p fj rrkontrollens display bild 16 Lodr ta fl ktlameller ndra luftfl det i lodr t riktning genom att trycka p knappen Symbolen visas p displayen Tryck upprepade g nge...

Page 20: ...p temperaturgivaren i konvektorfl kten E3 Lampan RUN blinkar tre g nger med 8 sekunders mellanrum Byt ut givaren 3 Fel p fl ktmotor E7 Lampan RUN blinkar sju g nger med 8 sekunders mellanrum Byt ut g...

Page 21: ...r r d ligt isolerade F rb ttra isoleringen D rrar f nster r ppna St ng alla d rrar f nster Fl kten g r l ngsamt St ll in en h gre fl kthastighet Sp nningen r f r l g Anslut konvektorfl kten till l mpl...

Page 22: ...utlopps nde befinner sig p l gre niv n fl ktens underkant Fl kten lutar kraftigt R ta upp fl kten Vibrationer och eller buller Fl ktmotorlagret r d ligt smort eller trasigt Sm rj lagret eller byt ut f...

Page 23: ...axv rde 4 Reng r luftfiltret vid behov men minst en g ng i halv ret G r s h r Lyft upp fl ktens frontpanel Var f rsiktig s att du inte lyfter upp panelen f r l ngt eftersom den kan lossna ppna panelen...

Page 24: ...avser modell med vattenventil 2 3 4 5 6 1 Str mkabel 2 Signal 3 Fl ktmotor 4 Motor 5 Rumstemperaturgivare 6 Fl ktgivare 7 Kretskort 8 Transformator 9 Evaporatorenhet 7 8 9 1 ANSL FL KT ANSL DISP AC N...

Page 25: ...g r enligt av Jula godk nd fackmans bed mning avvikelse fr n normal standard Fel eller bristf llighet som uppkommit genom onormal p verkan s v l mekanisk som milj m ssig r ej att anse som garanti Jula...

Page 26: ...onssystemer i offentlige og private bygninger samt bolighus Viftekonvektoren b r installeres pr vekj res og vedlikeholdes av en fagmann med god kjennskap til nasjonale forskrifter og erfaring med denn...

Page 27: ...39 kW Temperaturomr de 5 70 C Luftstr m varme 750 m h Lydniv 35 dB Vanntilkobling G3 8 Energiklasse A Spenning 230 v M l B89 x H28 x D21 cm Vekt 12 kg Varmeeffekten er angitt ved lufttemperatur 20 C o...

Page 28: ...s kaldtvann brukes stilles viften inn p kj ling for gj re rommet kj ligere Hvis varmtvann brukes stilles viften inn p varme for gj re rommet varmere Denne p litelige viftekonvektoren sparer energi er...

Page 29: ...is varme og ventilasjonssystemet er plassert innend rs og avl psslangen kan kobles til det eksisterende avl pssystemet er det ikke n dvendig bore hull i veggen I s fall kan r rene til b de inn og utg...

Page 30: ...venstre eller h yre for viften Hullet skal ha et lite fall mot utsiden bilde 2 og 3 5 Kontroller hvilke forskrifter som gjelder for r rgjennomf ring i yttervegger Se bilde 4 hvis gjennomf ringshylse k...

Page 31: ...nst 8 mm tykt bilde 6 Kontroller ogs at r risolasjonen er i overensstemmelse med nasjonale forskrifter D rlig isolasjon kan f re til redusert effektivitet OBS R risolasjonen skal omgi b de inn og utg...

Page 32: ...ende vann til VVS systemet Kontroller at tetningene er riktig montert OBS Ingen del av avl psslangen skal befinne seg p h yere niv enn viften LUFTING Etter at vannr r og avl psslange er koblet til og...

Page 33: ...ilen ved skru den opp for h nd eller med en nebbtang bilde 12 4 pne ventilen til vanninntaket slik at vannet renner inn i viften Kontroller at du ser vann i den gjennomsiktige slangen som er koblet ti...

Page 34: ...P Starter tidsuret 7 Vifte Brukes til velge viftehastighet auto lav middels h y 8 Timer og minutter Brukes til stille inn klokke og tidsur 9 Loddrette viftelameller Brukes til regulere luftstr mmen i...

Page 35: ...raturen som er innstilt med fjernkontrollen og basert p dette startes enten kj ling eller oppvarming N r nsket temperatur er innstilt for oppvarming eller kj ling slutter lampen RUN blinke Den standar...

Page 36: ...dardinnstillingen er 27 C Ved valg av varme kan det ta litt tid f r viften begynner g fordi det kan v re restkulde i systemet Stille inn temperaturen Velg f rst modusen oppvarming og bruk deretter kna...

Page 37: ...idspunktet bilde 14 Bruk knappen for stille inn stopptidspunktet Trykk f rst p Bruk deretter knappene HR og MIN for stille inn tidspunktet du vil at viften skal sl s av Hver gang du trykker p HR still...

Page 38: ...ymbolet vises p displayet I nattmodus kes senkes temperaturen med n grad annenhver time avhengig av om varme eller kj ling er valgt N r temperaturen endres 3 C brukes den gjeldende temperaturen i det...

Page 39: ...etene Valgt hastighet vises p displayet p fjernkontrollen bilde 16 Loddrette viftelameller Endre luftstr mmen i loddrett retning ved trykke p knappen Symbolet vises p displayet Trykk flere ganger p kn...

Page 40: ...il p temperaturgiveren i viftekonvektoren E3 Lampen RUN blinker tre ganger med 8 sekunders mellomrom Skift ut giveren 3 Feil p viftemotor E7 Lampen RUN blinker 7 ganger med 8 sekunders mellomrom Skift...

Page 41: ...isolasjonen D rer vinduer er pne Lukk alle d rer vinduer Viften g r sakte Still inn h yere viftehastighet Spenningen er for lav Koble viftekonvektoren til en egnet str mkilde Fjernkontrollen fungerer...

Page 42: ...psslangen befinner seg p lavere niv enn underkanten av viften Viften heller kraftig Rett opp viften Vibrasjoner og eller st y Viftemotorlageret er d rlig smurt eller delagt Sm r lageret eller skift u...

Page 43: ...verdi 4 Rengj r luftfilteret ved behov men minst en gang i halv ret Slik gj r du L ft opp frontpanelet p viften V r forsiktig s du ikke l fter panelet for langt opp Da kan det l sne pne panelet s lan...

Page 44: ...e gjelder modell med vannventil 2 3 4 5 6 1 Str mkabel 2 Signal 3 Viftemotor 4 Motor 5 Romtemperaturgiver 6 Viftegiver 7 Kretskort 8 Transformator 9 Fordamperenhet 7 8 9 1 KOBL VIFTE KOBL DISP AC N TR...

Page 45: ...r godkjent av Jula skal feil v re et avvik fra normal standard Feil eller mangler som har oppst tt som f lge av unormal p virkning b de mekanisk og milj messig omfattes ikke av garantien Jula har inte...

Page 46: ...o system w grzewczych i wentylacyjnych w budynkach u yteczno ci publicznej i prywatnych oraz w budynkach wielorodzinnych Instalacja uruchomienie pr bne i konserwacja klimakonwektora musz by przeprowad...

Page 47: ...zep yw powietrza ciep ego 750 m h Poziom ha asu 35 dB Przy cze wody G3 8 Klasa energetyczna A Napi cie 230 V Wymiary Szer 89xWys 28xG 21 cm Masa 12 kg Moc grzewcza podana jest dla temperatury powietrz...

Page 48: ...dy zimnej nale y ustawi konwektor na ch odzenie by sch odzi pomieszczenie Przy u yciu wody gor cej nale y ustawi konwektor na grzanie by ogrza pomieszczenie Ten niezawodny klimakonwektor oszcz dza ene...

Page 49: ...eli systemy grzewczy i wentylacyjny s umieszczone wewn trz budynku a w odp ywowy mo e by pod czony do istniej cego systemu kanalizacyjnego w wczas nie ma potrzeby wykonywania otwor w w cianach W takim...

Page 50: ...latora Otw r powinien mie ma y spadek w kierunku strony zewn trznej budynku rys 2 i 3 5 Sprawd przepisy dotycz ce przeprowadzania rur przez ciany zewn trzne Niezb dna jest tuleja przepustowa patrz rys...

Page 51: ...o najmniej 8 mm rys 6 Sprawd r wnie obowi zuj ce przepisy w zakresie izolacji rur Nieprawid owo wykonana izolacja mo e pogorszy wydajno UWAGA Izolacja powinna obejmowa zar wno rur wlotow jak i odp ywo...

Page 52: ...d do systemu centralnego ogrzewania Sprawd prawid owo zamontowania uszczelnie UWAGA aden z odcink w w a odp ywowego nie mo e znajdowa si nad konwektorem ODPOWIETRZANIE Po pod czeniu rury z wod i w a o...

Page 53: ...Odkr zaw r r k lub za pomoc szczypc w rys 12 4 Otw rz zaw r dop ywu wody a woda zacznie wp ywa do konwektora Sprawd czy widzisz wod w przezroczystym w u pod czonym do zaworu Konwektor jest w a ciwie o...

Page 54: ...auto ch odzenie osuszanie wentylator grzanie 5 Wy cz funkcj Timer Zatrzymuje wy cznik czasowy 6 W cz funkcj Timer Uruchamia wy cznik czasowy 7 Wentylator Stosowany do wyboru pr dko ci wentylatora aut...

Page 55: ...atur Wy wietlacz temperatury czasu kodu b du Wyb r trybu Naci nij by wybra tryb pracy konwektora Prze czanie pomi dzy poszczeg lnymi trybami przeprowadza si w nast puj cej kolejno ci Tryb automatyczny...

Page 56: ...y funkcji wy cznika czasowego jednak tryb czuwania nie mo e by aktywowany Wentylator w trybie osuszania zawsze pracuje na niskich obrotach Tryb wentylatora Naci nij trzykrotnie przycisk wentylatora by...

Page 57: ...Po zapisaniu ustawienia czasu wentylator si wy czy O zaprogramowanej porze wentylator si uruchomi a funkcja wy cznika czasowego si wy czy Ustawienie czasu wy czania rys 14 U yj przycisku by ustawi cza...

Page 58: ...Na wy wietlaczu uka e si symbol W trybie nocnym temperatura obni a si podwy sza si o jeden stopie co godzin w zale no ci od wyboru ogrzewania lub ch odzenia Po zmianie temperatury o 3 C temperatura j...

Page 59: ...dko ciami Wybrana pr dko zostanie pokazana na wy wietlaczu rys 16 Pionowe lamele wentylatora Zmie kierunek wyp ywu powietrza na pionowy naciskaj c przycisk Na wy wietlaczu uka e si symbol Naciskaj prz...

Page 60: ...Usterka czujnika temperatury w klimakonwektorze E3 Lampka RUN miga trzy razy w odst pach co 8 sekund Wymie czujnik 3 Usterka silnika wentylatora E7 Lampka RUN miga siedem razy w odst pach co 8 sekund...

Page 61: ...opraw izolacj Drzwi okna s otwarte Zamknij wszystkie drzwi okna Wentylator pracuje powoli Ustaw wy sz pr dko wentylatora Napi cie jest zbyt niskie Pod cz klimakonwektor do odpowiedniego r d a pr du Pi...

Page 62: ...j w a odp ywowego tak by znajdowa a si poni ej dolnego brzegu wentylatora Wentylator mocno si odchyla Wypoziomuj wentylator Drgania i lub ha as o ysko silnika wentylatora jest s abo nasmarowane lub ze...

Page 63: ...eratur na maksimum 4 W razie potrzeby wyczy filtr powietrza jednak nie rzadziej ni raz na p roku Wykonaj nast puj ce czynno ci Podnie panel przedni Zr b to ostro nie i nie podnie panelu zbyt wysoko gd...

Page 64: ...zaworem wody 2 3 4 5 6 1 Kabel zasilaj cy 2 Sygna 3 Silnik wentylatora 4 Silnik 5 Czujnik temperatury pomieszczenia 6 Czujnik wentylatora 7 P ytka drukowana 8 Transformator 9 Parownik 7 8 9 1 POD WEN...

Page 65: ...wed ug oceny zatwierdzonego przez firm Jula specjalisty odchylenie od normy Usterka lub inna szkoda kt ra powsta a na skutek nietypowego oddzia ywania mechanicznego lub rodowiskowego nie jest obj ta...

Page 66: ...gs as well as in residential homes The convector fan should be installed tested and maintained by a technician with a good understanding of national regulations and experience with this kind of produc...

Page 67: ...Airflow heat 750 m h Sound Level 35 dB Water connection G3 8 Energy class A Voltage 230 V Dimensions W89 x H28 x D21 cm Weight 12 kg The stated heat output corresponds to an air temperature of 20 C w...

Page 68: ...the room If cold water is used set the fan to cool in order to make the room cooler If hot water is used set the fan to heat in order to make the room warmer This reliable convector fan saves energy...

Page 69: ...ion system is situated indoors and the drainage hose can be connected to the existing drainage system it is not necessary to make holes in the wall In such case the tubes for both incoming and outgoin...

Page 70: ...of the fan The hole shall have a brief descent toward the outdoor side figures 2 and 3 5 Check which regulations apply to pipe lead throughs on external walls If a lead through casing is needed see fi...

Page 71: ...ast 8 mm thick figure 6 Also check that the pipe insulation corresponds to national regulations Poor insulation can lead to impaired effectiveness NB The pipe insulation should enclose both incoming a...

Page 72: ...he heating and ventilation system Check that the seals are correctly mounted NB No part of the drainage hose may be situated at a level higher than the fan VENTING After having connected the water pip...

Page 73: ...Open the valve by unscrewing it by hand or with flat pliers figure 12 4 Open the valve for incoming water so that the water runs into the fan Check that you see water in the transparent hose which is...

Page 74: ...Turns off the timer 6 Timer ON Starts the timer 7 Fan Used to select fan speed auto low medium high 8 Hours and minutes Used to set the clock and timer 9 Horizontal fan slats Used to regulate the airf...

Page 75: ...erature is compared with the desired temperature that has been set via the remote control and based on this either cooling or heating is initiated The RUN light stops flashing when the desired tempera...

Page 76: ...m 16 31 C The default setting is 27 C It may take a moment for the fan to start when selecting heating as residual cold may be present Setting the temperature First select the mode for heating then us...

Page 77: ...he button to set the stop time First press Then use the HR and MIN button to set the time when you want the fan to turn off Each time you press HR the time is moved forward by one hour Each time you p...

Page 78: ...layed on the screen During night mode the temperature is raised lowered by one degree every other hour depending on whether heating or cooling has been chosen Once the temperature has changed by 3 C t...

Page 79: ...The selected speed is shown on the remote control s display figure 16 Horizontal fan slats Adjust the airflow horizontally by pressed the button The symbol is shown on the display Repeatedly press th...

Page 80: ...in the convector fan E3 The RUN light flashes three times at an 8 second interval Replace the sensor 3 Fault in the fan motor E7 The RUN light flashes seven times at an 8 second interval Replace the s...

Page 81: ...on Doors windows are open Close all doors windows The fan is running slowly Set at a higher fan speed The voltage is too low Connect the convector fan to a suitable power supply Remote control is not...

Page 82: ...he drainage hose s drain end is situated lower than the fan s lower edge The fan is leaning substantially Straighten the fan Vibrations and or noise The fan s motor bearing is poorly lubricated or bro...

Page 83: ...filter as needed but at least once every six months Use the following instructions Lift up the fan s front panel Be careful not to lift the panel up too high as it can come loose Open the panel as fa...

Page 84: ...ers to a model with a water valve 2 3 4 5 6 1 Power cord 2 Signal 3 Fan motor 4 Motor 5 Room temperature sensor 6 Fan sensor 7 Circuit board 8 Transformer 9 Evaporator unit 7 8 9 1 ANSL FAN ANSL DISP...

Page 85: ...duct According to a Jula approved professional assessment faults constitute a departure from the normal standard Faults or defects caused by abnormal actions both mechanical and environmental are not...

Reviews: