Chapter 1 Overview
1-18
No.
Item
Specifications
LP-IAIS
Detection: b4 “1” of Z6/N2 in 1-15 frames (5 frames)
Removal: Excluding above in 1-15 frames (5 frames)
LP-TC-RDI
Detection: TC-RDI = 1 of Z5/N1 or Z6/N2 in 1-15 frames
(5 frames)
Removal: Excluding above in 1-15 frames (5 frames)
LP-ODI
Detection: ODI = 1 in 1-15 frames (5 frames)
Removal: Excluding above in 1-15 frames (5 frames)
HP-TCUNEQ
Detection: IEC = “0000” of IEC in 1-15 frames (5
frames)
Removal: Excluding above in 1-15 frames (5 frames)
LP-TCUNEQ
Detection: b3
=
“0” of Z6/N2 in 1-15 frames (5 frames)
Removal: Excluding above in 1-15 frames (5 frames)
RS-TIM
Detection: J0
≠
expected value in 5 frames
Removal: J0 = expected value in 5 frames
TIM-P/HP-TIM
Detection: J1
≠
expected value in 5 frames
Removal: J1 = expected value in 5 frames
TIM-V/LP-TIM
Detection: J1 or J2
≠
expected value in 5 frames
Removal: J1 or J2 = expected value in 5 frames
HP-TCTIM
Detection: TC-API
≠
expected value in 1-15 frames (5
frames)
Removal: TC-API = expected value in 1-15 frames (5
frames)
LP-TCTIM
Detection: TC-API
≠
expected value in 1-15 frames (5
frames)
Removal: TC-API = expected value in 1-15 frames (5
frames)
AU/TU-LOP can be switched with or without SS bit.
3.1.2.16
Pointer action
measurement
Justification
Element
Measurement range
STS/VT-PTR, AU/TU-PTR, C, C1/C2
NDF, +PJC,
−
PJC, Cons.C, C1/C2
Count: 0 to 999999, 1.0E06 to 9.9E15, 9.9E15
Rate: 1.0E
−
15 to 9.9E
−
01, 1.0E
−
00, <1.0E
−
15
ppm:
−
1000 to +1000 ppm/in 0.1 ppm steps, <overflow