MU120131A/32A PON Quck Start Guide
17
4.4. Checking Flow from Each ONU (Setting OLT
ONU Tx/Rx Counter)
(Objective)
Checking that throughput of signal from each ONU is at set value (flowing normally)
(Procedure)
Use the multiflow counter to count the Bit Rate and number of Frames of each
stream at the OLT side.
(Results, Goal)
Count of multiple flows at one port and clarify throughput (ONU
→OLT stream
(Up signal)
Setting Multi Flow Counter for OLT Side
(1) Opening Counter Setting Screen
Select Unit4 Port12 (Unit1:4:12) for the measured port.
Open the
□Counter screen and press the counter icon (hammer symbol) to open the
Setting screen.