Page 1: ...Anritsu MT8222A Manual Get Pricing Availability at ApexWaves com Call Today 1 800 915 6216 Email sales apexwaves com https www apexwaves com analyzers anritsu bts master MT8222A...

Page 2: ...BTS Master User Guide MT8222A The High Performance Handheld Base Station Analyzer...

Page 3: ...Anritsu Company 490 Jarvis Drive Morgan Hill CA 95037 2809 P N 10000 00000 Revision Prelim Printed November 2010...

Page 4: ...ptions The documentation set is available as PDF files on the documentation disc and the Anritsu web site Anritsu Company 490 Jarvis Drive Morgan Hill CA 95037 2809 P N 10000 00000 Revision Prelim Pri...

Page 5: ...REPLACEMENT NO LIABILITY FOR CONSEQUENTIAL DAMAGES TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW IN NO EVENT SHALL ANRITSU COMPANY OR ITS SUPPLIERS BE LIABLE FOR ANY SPECIAL INCIDENTAL INDIRECT OR...

Page 6: ......

Page 7: ......

Page 8: ...or approval by the government of the product country of origin for re export from your country Before you export this product or any of its manuals please contact Anritsu Company to confirm whether o...

Page 9: ......

Page 10: ...bels attached to products that are not shown in the diagrams in this manual This indicates a prohibited operation The prohibited operation is indicated symbolically in or near the barred circle This i...

Page 11: ...ve the equipment covers or to disassemble internal components Only qualified service technicians with a knowledge of electrical fire and shock hazards should service this equipment There are high volt...

Page 12: ...mory Types 1 7 Erase All User Files in Internal Memory 1 8 Recommended Usage in a Secure Environment 1 8 Chapter 2 Instrument Overview 2 1 Introduction 2 1 2 2 Hardware Overview 2 2 Turning On the MT8...

Page 13: ...mplitude Range and Scale 3 3 Power Offset Set Up for Compensating External Loss 3 4 3 5 Set the Span 3 4 3 6 Setting Up Limit Lines 3 5 Single Limit Line 3 5 Segmented Limit Lines 3 5 Limit Line Envel...

Page 14: ...the GPS feature 6 2 6 3 GPS Menu 6 4 Chapter 7 Anritsu Tool Box and Line Sweep Tools 7 1 Introduction 7 1 7 2 Anritsu Tool Box with Line Sweep Tools 7 1 7 3 Install the Software 7 2 7 4 Other Software...

Page 15: ...Messages B 1 Introduction B 1 B 2 Self Test or Application Self Test Error Messages B 1 B 3 Operation Error Messages B 2 Appendix C LAN and DHCP C 1 Introduction C 1 C 2 Ethernet Configuration C 1 LA...

Page 16: ...t two port gain loss one port and two port magnitude and phase interference analysis spectrogram and power meter RF advanced demodulation and over the air OTA measurements can be applied to WCDMA HSDP...

Page 17: ...in a CompactFlash module or in a USB Flash drive Stored measurements can be downloaded to a PC by using the included USB and Ethernet cables After being stored a graphic trace can then be displayed s...

Page 18: ...arge may damage the MT8222A input circuitry MT8222A operators must be aware of the potential for ESD damage and take all necessary precautions Operators should exercise practices outlined within indus...

Page 19: ...talled in the BTS Master by using either the AC DC Adapter 40 168 R or the 12 Volt DC adapter 806 141 R or separately in the optional Dual Battery Charger 2000 1374 Refer to section Symbols and Indica...

Page 20: ...face down into the case taking care that the connectors are properly situated in the case top opening You may find it easier to insert the connectors first then pull the corners over the bottom of the...

Page 21: ...bail provides a backward tilt for improved stability and air flow To deploy the tilt bail pull the bottom of the tilt bail away from the back of the instrument To store the tilt bail push the bottom...

Page 22: ...ocess all operating parameter stored in the EEPROM are set to standard factory default values RAM Memory This is volatile memory used to store parameters needed for the normal operation of the instrum...

Page 23: ...curely retained sanitized or destroyed after use To set the BTS Master to save files to the CompactFlash memory 1 Insert the CompactFlash cart and turn the instrument on 2 Press the Shift button then...

Page 24: ...ter 3 Basic Measurement Setups to find directions for power on editing frequency bandwidth amplitude limit line marker file management procedures and firmware update For more detailed information on m...

Page 25: ...DC Automotive Cigarette Lighter Adapter Anritsu part number 806 141 R Both items are included as standard accessories To turn on the MT8222A press the On Off button on the front panel Figure 2 1 The M...

Page 26: ...shift key to access the functions that are printed on the panel The Escape key which is used for aborting data entry is the round button located above the submenu keys The rotary knob the four arrow k...

Page 27: ...elow the measurement display screen the 5 main menu keys The hard keys perform as follows Esc Key Press this key to cancel any setting that is currently being made Enter Key Press this key to finalize...

Page 28: ...Menu Keys The 5 main menu keys are horizontally arranged adjacent to the measurement display screen and along its lower edge These keys buttons have no printed labels They are positioned to accompany...

Page 29: ...the Mode 9 key Use the directional arrow keys or the rotary knob to highlight the selection and press the Enter key to select The list of modes that appears in this menu will vary depending upon the o...

Page 30: ...unction Menus are active in various operation Modes If any one of these 9 menus is available in a specific instrument Mode of operation then it can be called from the number keypad It may also be avai...

Page 31: ...yed on your BTS Master Cable and Antenna Analyzer Mode Figure 2 6 illustrates some of the key information areas of the MT8222A display in Cable and Antenna Analyzer mode For more detailed key descript...

Page 32: ...or more detailed key descriptions of the Spectrum Analyzer mode refer to the Spectrum Analyzer Measurement Guide available on the documentation disc Also refer to Appendix A Measurement Guides for a c...

Page 33: ...lay For detailed WCDMA HSDPA information refer to the 3GPP Measurement Guide Anritsu part number 10580 00234 available on the documentation disc and the Anritsu web site Also refer to Appendix A Measu...

Page 34: ...nas or couplers can be added to list boxes by creating them and importing them through the use of Master Software Tools 2 9 Text Entry When entering text as when saving a measurement the submenu key f...

Page 35: ...2 9 Text Entry Instrument Overview 2 12 PN 10580 00156 Rev T BTS Master UG Figure 2 9 Text Entry Menu Lower Case Figure 2 10 Text Entry Menu Upper Case Lowercase Text Entry Uppercase Text Entry...

Page 36: ...Instrument Overview 2 9 Text Entry BTS Master UG PN 10580 00156 Rev T 2 13 Figure 2 11 Text Entry Menu Selecting Characters Rotary Knob has scrolled to letter c...

Page 37: ...e following text Figure 2 12 Test Panel Connectors including T1 and T3 Figure 2 13 Test Panel Connectors Including E1 External Power LAN Connection USB Interface Mini B Headset Jack External Trigger E...

Page 38: ...ROM in the computer drive and specify that the installation wizard should search the CD ROM for the driver USB Interface Type A The MT8222A BTS Master can also be a USB Host and allow various USB Fla...

Page 39: ...pe N female connector T1 T3 Bantam Jacks BERT tester Option 51 and Option 53 Bantam jacks for transmit and receive GPS Antenna Connector GPS antenna connection CompactFlash Card Accepts a 256 MB Compa...

Page 40: ...ry is charging either from the AC DC Adapter 40 168 R or the 12 Volt DC adapter 806 141 R the symbol changes to that shown in Figure 2 15 The Battery Charge LED refer to Figure 2 2 on page 2 3 flashes...

Page 41: ...current submenu title is shown at the top of submenu key labels Refer to Figure 2 2 on page 2 3 Table 2 1 Mode Dependent Main Menu Keys Located Below Measurement display Mode Key 1 Key 2 Key 3 Key 4 K...

Page 42: ...ides and their Anritsu part numbers 3 2 Measurement Setup Connect the Input Source Connect the input signal or antenna to the appropriate test connector on the top of the instrument For connector desc...

Page 43: ...appropriate unit key Pressing the Enter key has the same affect as pressing the MHz submenu key The current setting is shown at the top of the instrument settings summary column on the left side of t...

Page 44: ...ter key to set The y axis scale is automatically renumbered Note To change the current measurement units press the Units submenu key and select the required units from the submenu keys that are presen...

Page 45: ...0 dB When using the Up Down arrow keys the value changes in increments of 10 0 dB When using the keypad enter the new value then press Enter or the dB submenu key to set the value The power offset is...

Page 46: ...3 Press the Single Limit submenu key to change the location of the limit line on the y axis 4 If necessary press the Set Default Limit submenu key to display the limit line Segmented Limit Lines Spec...

Page 47: ...sing the Next Point Left submenu key 5 Press the Add Point submenu key to place a new point on the limit line Use the Point Freq and Point Value submenu keys to set the frequency and dB level of the p...

Page 48: ...e moved 3 Use the rotary knob to place the marker on the desired frequency 4 Repeat Step 1 and Step 2 to activate and move multiple markers Selecting Activating and Placing a Delta Marker 1 Press the...

Page 49: ...3 8 PN 10580 00156 Rev T BTS Master UG...

Page 50: ...ly save measurements with a specific file name The BTS Master saves the measurement with the latest file name that was used to save a measurement and with a number that is automatically incremented an...

Page 51: ...the file type you want to view Recall a Measurement From the File menu press the Recall Measurement submenu key select the measurement with the rotary knob or the Up Down arrow keys and press Enter Re...

Page 52: ...he File main menu press the Copy submenu key The Copy submenu and Copy dialog box are displayed 3 Select the file s to copy To select multiple files highlight the first then press the Select or De Sel...

Page 53: ...own arrow keys Press the Select or De Select key The file will be highlighted in blue when selected Press the Delete key and Enter to delete the selected file Delete Dialog Box Press the Delete submen...

Page 54: ...ctories Recall Sort By Name Date Type Sort Order Asc Desc File Type ALL Select or De Select Delete Refresh Directories Delete Sort By Name Date Type Sort Order Asc Desc Scroll Scr Dst File Type ALL Re...

Page 55: ...e for external data storage Refer to the BTS Master Technical Data Sheet listed in Appendix A for the Anritsu Part Number of the USB flash drive The saved setup measurement or JPEG file can be named b...

Page 56: ...for capital letters Press the Enter key or the rotary knob to finalize a text entry Back Space Use this key to delete a file name highlighted in blue or delete individual characters Change Save Locati...

Page 57: ...By Press this submenu key to sort the folders by Name Type or Date Sort Order Displays the folder names in ascending or descending order Create Folder This key will create a new folder in the highligh...

Page 58: ...ggling this submenu key to On will save the measurement to internal memory after the current sweep is complete If Save Then Stop is toggled Off a measurement will be saved after every sweep Save Then...

Page 59: ...e Sort By key File Type Press this submenu key to select what type of file is viewed The options are the ALL Measurement or Setup The file type can be changed with the Up Down keys or the rotary knob...

Page 60: ...easurement Setup or Jpeg The file type can be changed with the Up Down keys or the rotary knob Press Enter to make the selection Refresh Directories Press this key to update the display Scroll Press t...

Page 61: ...ype Press this submenu key to select what type of file view for deleting The options are the ALL Measurement Setup Limit Lines or Jpeg The file type can be changed with the Up Down keys or the rotary...

Page 62: ...hapter will review the BTS Master system operations System Menu Overview on page 5 2 System Menu on page 5 3 Preset Menu on page 5 6 Self Test on page 5 6 Update Firmware on page 5 7 The other menus S...

Page 63: ...em 8 key Figure 5 1 System Menu GPS System Back System Options Application Options Reset GPS GPS On Off Status Self Test Application Self Test GPS Info Reset Back Back System Options Date Time Etherne...

Page 64: ...or Enter to return to normal operation Application Self Test Press this submenu key to initiate a series of diagnostic tests that are related to the performance of the measurement mode A display list...

Page 65: ...ons available English is the default language Press Enter to accept the change or press the Esc key to return to normal operation without changes In addition any existing language except English may b...

Page 66: ...ters including Ethernet language and brightness settings Also all user files in the internal memory are deleted and the original language and antenna files are restored Press the Enter key to initiate...

Page 67: ...contact your Anritsu Service Center To initiate a self test when the system is already powered up 1 Press the Shift key and then the System 8 key 2 Press the Self Test submenu key The Self Test resul...

Page 68: ...re is loaded onto the CompactFlash card or USB memory device follow the instructions below to update the firmware on your BTS Master 1 Insert the USB memory stick into the USB port 2 Press the follow...

Page 69: ...ce Save Restore User data will be saved to the selected external media device The instrument will also attempt to restore the files to the instrument after the update 7 Press Enter to begin the firmwa...

Page 70: ...Esc to abort Figure 5 8 9 Select Enter and the firmware update process begins and the Firmware Update dialog displays the following message Updating firmware Please Wait 10 When complete the instrume...

Page 71: ...5 10 PN 10580 00156 Rev T BTS Master UG...

Page 72: ...3 Basic Measurement Setups to find directions for power on editing frequency bandwidth amplitude limit line marker file management procedures and firmware update For more detailed information on meas...

Page 73: ...GPS menu refer to GPS Menu on page 6 4 4 Activate GPS by pressing the GPS On Off submenu key so that On is underlined When GPS is first turned On the GPS icon is displayed in red 5 Press the GPS Info...

Page 74: ...rnal standard accuracy is 0 3 PPM The correction factor applied to the internal OCXO allows the instrument to maintain GPS frequency accuracy for three days at better than 50 ppb even when the instrum...

Page 75: ...GPS Press this submenu key to turn GPS on or off GPS Info Press this submenu key to display the current GPS information Reset Press this submenu key to reset the GPS for a new location Back Press thi...

Page 76: ...itsu Tool Box is a central location to open an Anritsu measurement visit the Anritsu web site or launch an Anritsu application Figure 7 1 To open the Anritsu Tool Box either click on the shortcut icon...

Page 77: ...ons The software is also available free of charge from the Anritsu web site http www anritsu com 7 4 Other Software The Anritsu Tool Box may also link to the Anritsu Master Software Tools software and...

Page 78: ...users of Hand Held Software Tools the current industry standard line sweep post capture trace processing software This leads to a short learning curve and easy trace collection validation and reportin...

Page 79: ...ools saves files as a new type of DAT file and can export traces as VNA text JPG BMP or PNG Line Sweep Tools does not produce files that can be opened by HHST Markers and Limit Lines The easiest way t...

Page 80: ...the markers and limit lines Finally press the red e button again to exit the learn mode The programmed button is now enabled Line Sweep Tools can program up to 7 buttons with preset markers and limit...

Page 81: ...Remember Fields to copy the new name for later use 5 On the toolbar press the button that corresponds to the field to be renamed 6 If desired use the arrow keys on the Marker toolbar to go to the next...

Page 82: ...ne Sweep Tools BTS Master UG PN 10580 00156 Rev T 7 7 Once the report generator is setup File Generate Report will create the PDF The report will include all traces that were open at the time the repo...

Page 83: ...7 8 PN 10580 00156 Rev T BTS Master UG...

Page 84: ...ture the current screen and associated data from the test instrument to the Master Software Tools Graphic Display Editor window Saved files on the test instrument can also be retrieved and displayed o...

Page 85: ...ls MST User Guide on the CD ROM for information regarding connecting your BTS Master to a PC 2 Run Master Software Tools 3 FromtheConnectionmenu for a USB Connection Select Connect USB for an Ethernet...

Page 86: ...mmediately click Install to Unit to update your BTS Master with the new firmware File Status Available In Figure 8 4 the status of the highlighted file is Available and the Install to Unit button is g...

Page 87: ...Click the Install to Unit button Your BTS Master is updated with the new firmware File Status Available 1 Check that the file status is Available 2 Click Retrieve File to download the file from the We...

Page 88: ...ted in the file menu 2 Click the Retrieve File button The file is transferred from the Web site to your PC 3 After the status changes to Ready click the now active Install to Unit button Your BTS Mast...

Page 89: ...Ethernet cross over cable 3 Turn on the BTS Master in bootstrap mode as follows a With the BTS Master off hold the first third and fifth submenu keys located at the right edge of the measurement displ...

Page 90: ...DHCP Lease Failed will be displayed at the lower left corner of the measurement display screen Go to Step 6 DHCP Mode Second Attempt If your BTS Master is configured for STATIC IP then it opens to the...

Page 91: ...subnet mask d Attach the Ethernet network cable between the test instrument and your PC e Press the Back submenu key to return to the main bootstrap screen 8 Press the Update OS Ethernet submenu key...

Page 92: ...firmware that you wish to load into your BTS Master If its status is Ready then the file is located on the PC and the Emergency Repair button is active If the file status is listed as Available then c...

Page 93: ...several minutes 14 When your BTS Master is done loading the new OS firmware it should automatically reboot If it does not reboot turn off the BTS Master then turn it on The BTS Master should start up...

Page 94: ...Generator 0028 Gated Sweep 0090 Spectrum Analyzer Measurement Guide 10580 00231 for Firmware V1 69 and BEFORE Spectrum Analyzer Measurement Guide 10580 00244 for Firmware AFTER V1 69 High Accuracy Pow...

Page 95: ...Air Signal Analyzer 0037 WiMAX Signal Analyzer Measurement Guide 10580 00236 DVB T H Measurements 0064 Digital Video Broadcast Signal Analyzer Measurement Guide 10580 00237 T1 Analyzer 0051 E1 Analyze...

Page 96: ...ll erase all user saved setups and measurement traces and return the unit to a fully Factory Default condition If the error persists contact your Anritsu Service Center Lock Test FAILED One or more Ph...

Page 97: ...enuation increasing the Reference Level should resolve the error See also the Mixer Overdrive error above for information on Out of band RF power Calibrator Reading Error Calibration reference source...

Page 98: ...Sideband Demodulation mode Trace A B C has no data to view Attempt to turn on or VIEW a trace that has never had data recalled into this trace location Refer to Recall Trace section for instructions o...

Page 99: ...ker Current Marker is not ON Attempted to use a marker mode or feature for a marker that is not enabled Turn on the appropriate marker to use this function or switch to a marker that is already enable...

Page 100: ...n or that the temperature is within acceptable limits Reset to factory defaults with either Factory Defaults ESC ON or MASTER RESET System ON Caution Use of MASTER RESET System ON will erase all user...

Page 101: ...uctions and allowing the unit to cool reset to the factory defaults with either Factory Defaults ESC ON Caution Use of MASTER RESET System ON will erase all user saved setups and measurement traces an...

Page 102: ...amic Host Configuration Protocol DHCP is an Internet protocol that automates the process of setting IP addresses for devices that use TCP IP and is the most common method of configuring a device for n...

Page 103: ...instrument on press the Shift key then the System 8 key then the System Options submenu key and the Ethernet Config submenu key The IP address will be displayed as shown in Figure C 1 The image on th...

Page 104: ...BTS Master UG PN 10580 00156 Rev T C 3 Ethernet Config Press this submenu key to display the Ethernet submenu and to open the Ethernet Editor dialog box in order to set the IP address of the instrumen...

Page 105: ...r to accept the changes or press the Esc key to return to normal operation without changing anything Field IP G Way Sub Press this submenu key to select the desired Internet Protocol Property to be ed...

Page 106: ...being set it will always remain the same and care must be taken to not conflict with other equipment on the network When using a static IP address on an established network always request the Static...

Page 107: ...ateway 153 56 100 1 Subnet Mask 255 255 252 0 C 4 ipconfig Tool A few tools that are built into the Microsoft Windows operating system can assist in making some determinations about the network to whi...

Page 108: ...d connection is found then a copy of the signal that was sent is returned If a connection is not found then the response is request timed out which means that no reply was received from that IP addres...

Page 109: ...C 8 PN 10580 00156 Rev T BTS Master UG...

Page 110: ...eries and chargers 2 17 cleaning solvents 1 2 ESD 1 3 change directory 4 7 CompactFlash module 1 2 connectors test panel illustration 2 14 copy menu 4 11 create folder 4 8 D default gateway for IP add...

Page 111: ...g bandwidth 3 2 setting frequency 3 2 setting span 3 4 setting up GPS 6 2 setting up limit lines 3 5 setting up markers 3 7 menu copy 4 11 delete 4 12 Ethernet 8 7 C 4 file 4 6 GPS 6 4 mode selector 2...

Page 112: ...oup 5 2 self test 5 6 T test panel 2 14 tilt bail 1 6 trigger external 2 15 external connector 2 14 U updates product updates window 8 2 updating firmware problems 8 6 via Ethernet 8 2 via USB 5 7 8 2...

Page 113: ...Index 4 PN 10580 00156 Rev T BTS Master UG...

Page 114: ...Anritsu Company 490 Jarvis Drive Morgan Hill CA 95037 2809 P N 10000 00000 Revision Prelim Printed November 2010...

Page 115: ...Anritsu Company 490 Jarvis Drive Morgan Hill CA 95037 2809 USA http www anritsu com Anritsu Company Prints on Recycled Paper with Vegetable Soybean Oil Ink...