background image

6

2.

RJ45 patch cables category 5 that connect the ArcPower 7/K each other are wired 1:1,that is,pins with the 

same numbers are connected together.

 

 

Pin 1:

 Not used  

 

 

 

 

 

Pin 1:

 Not used 

 

 

Pin 2:

 Not used  

 

 

 

 

 

Pin 2: 

Not used 

 

 

Pin 3:

 Not used  

 

 

 

 

 

Pin 3:

 Not used

 

 

Pin 4:

 Not used  

 

 

 

 

 

Pin 4: 

Not used

 

 

Pin 5:

 Not used  

 

 

 

 

 

Pin 5: 

Not used

 

 

Pin 6:

 Data +   

 

 

 

 

 

Pin 6: 

Data +

 

 

Pin 7:

 Data -   

 

 

 

 

 

Pin 7: 

Data -

 

 

Pin 8:

 GND 

 

 

 

 

 

 

Pin 8: 

GND

5.Installing instructions.

 

 

Never connect 1W LEDs modules to the ArcPower 72/K2 

5.1.DMX operating

1.Unplug from the mains before installation.

2.Connect the LED modules to the fixture.Make sure that all modules include Luxeon K2 LED´s.

3.Connect the DMX controller to the fixture

4.Connect the fixture to the mains

5.Set the DMX address on the control board of the fixture (see chapter "Control board"). 

6.

Check the current limit setting "C.Li" in menu "SPE" (see chapter "8.6 Special functions")

 

 

 

 

 

Warning!

Accidental connection DMX 512 Input/Output to non-DMX 512 device (e.g.Ethernet 

network Hub) can damage the ArcPower 72/K2.

      Maximum total cable length between one LED zone output of the Arcpower 72/K2 

and all its connected LED modules is 40 metres.

Single ArcPower 72/K2 installation:

Summary of Contents for ArcPower 72/K2

Page 1: ...version 1 7...

Page 2: ...rating via DyNet protocol 9 6 ArcPower 72 K2 Control menu map 10 7 ArcPower 72 K2 DMX protocol 11 8 Control board 12 8 1 Addressing the ArcPower 72 K2 12 8 2 Program running 12 8 3 Manual mode 13 8 4...

Page 3: ...fied employee Do not connect this unit to a dimmer pack Use a source of AC power that complies with local building and electrical rules AC power has to have both overload and short circuit protection...

Page 4: ...re the end of the the supply cord and fit a suitable plug A 3 prong grounding type plug must be 1 Control board 2 Power Indicator 3 DMX Output 4 DMX Input 5 LED Zone outputs 6 RS 232 Output 7 Fuse Hol...

Page 5: ...ientation and fixed by the 4 screws There are 4 mounting holes of diameter 5 mm in housing of the driver Ensure that instalation place is enough ventilated 4 3 Conection cables 1 The adapter cable RJ4...

Page 6: ...g from the mains before installation 2 Connect the LED modules to the fixture Make sure that all modules include Luxeon K2 LED s 3 Connect the DMX controller to the fixture 4 Connect the fixture to th...

Page 7: ...n be chained together At the last ArcPower 72 K2 the data link has to be terminated with a terminator A termination plug is simply a RJ45 connector with a 120 resistor between pins Data and Data Plug...

Page 8: ...ll slaves are connected Up to 32 fixtures can be connected in master slave chain 4 Insert the termination plug with 120 Ohm into DMX input of the master fixture and into the DMX output of the last sla...

Page 9: ...l level Byte 3 80 Channel Byte 4 ff Channel Offset Byte 5 00 Fade Rate Byte 6 FF fixed value Byte 7 1C Checksum Area 0 to 255 as set on the Arcpower to give a unique address for each Arcpower unit i e...

Page 10: ...0 255 MAn rE1 0 255 FA t 0 255 Gr1 0 255 S tI 0 255 bL1 0 255 COP MAC 0 255 Str 0 255 diM 0 255 tSt St A MSt E P 1 P06 SLA SPE VEr bAL On OFF C bA rE b 0 200 Gr b 0 255 bL b 0 215 Zon Z 00 Z 08 d MP M...

Page 11: ...135 136 143 144 151 152 159 160 167 168 175 176 183 184 191 192 199 200 207 208 215 216 223 224 231 232 239 240 247 248 255 Macro selection No function Macro 1 Macro 2 Macro 3 Macro 4 Macro 5 Macro 6...

Page 12: ...the starting DMX address from which the ArcPower 72 K2 will respond to the DMX controller Setting the DMX start channel for DMX operating 1 Connect ArcPower 72 K2 to the mains 2 Browse through the men...

Page 13: ...p select option COP and confirm it by pressing ENTER Both Fade time and Standing time use the same conversion table in order to convert DMX value to the time value DMX Time sec DMX Time min DMX Time m...

Page 14: ...ion switch on both master and slave at a time or first slave s and after that master Running program has to be the same on all fixtures Note If the master runs its editable program EP1 EP2 or EP3 all...

Page 15: ...rect values The menu items their name and order stated below match to a standard RGBW colour variant of LED modules connected to both LED inputs zones rE1 red LED s at zone 1 R rE2 red LED s at zone 2...

Page 16: ...ture control panel SPE UPd yES From this option you cannot return back to the main menu If you do not want to continue in software update you have to switch off and on the fixture to leave this option...

Page 17: ...main menu of the ArPower 72 K2 press ENTER use UP and DOWN buttons to select Zon The option enables to select desired number of the zone from 0 to 8 Press ENTER use UP and DOWN buttons to select zone...

Page 18: ...means DMX value of the green colour 0 255 b means DMX value of the blue colour 0 255 means end of character sequence values of colours have to be separated by a comma Examples zone 0 234 126 165 zone...

Page 19: ...e LED zone output and all its connected LED modules 20 metres at max load DMX channels Mode 1 6 channels Mode 2 8 channels Mode 3 11 channels Mode 4 4 channels Mode 5 4 channels Control and programmin...

Page 20: ...45 DMX 5 pin No 13050731 11 Replacing the fuse 1 Before replacing the fuse unplug mains lead 2 Unscrew the fuse holder on the rear side of the ArcPower 72 K2 with a fitting screwdriver from the housin...

Reviews: