19
No.
Functions
Content
K X
Actual
Size
Display
Display the actual size of the existing pattern in X
direction.
L
X Scaling Rate Setting
Display the scaling rate of the existing pattern in X
direction
M
Y Actual Size Display
Display the actual size of the existing pattern in Y
direction.
N
Y Scaling Rate Setting
Display the scaling rate of the existing pattern in Y
direction
O
Max. Speed limitation
Display limited value on the Max. speed
P
Y travel amount display
Display the travel amount of the present pattern in Y
direction
Q
Return to normal pattern data
input
Return to the interface for normal pattern data input
R
P pattern file folder number
display
Display the number of the present P pattern file
folder
S
P pattern file folder selection
Shift the P pattern file folder number orderly
T
P pattern selection
Display the registered p pattern.
3.2 P Pattern Edition
①
Entry to Interface of P Pattern
Edition Interface
Press
to have access to the P
pattern edition interface (as shown in
the right).
②
Edition of Item Data
Select the item needing changing, and
then set the value.
Item
Input
Range
Default
A
X Scaling Rate
1.0~400.
0%
100.0%
B
Y Scaling rate
1.0~400.
0%
100.0%
C
Max. Speed
Limitation
200~270
0rpm
2700rp
m
D
Sewing Shape
E
File Folder
Number
1~5
F
X Travel Amount
-5.0~5.0
mm
0
G
Y Travel Amount
-5.0~5.0
mm
0
www.garudan.cz
Summary of Contents for GARUDAN GPS/F-1006 Series
Page 2: ...w w w g a r u d a n c z...
Page 4: ...w w w g a r u d a n c z...
Page 47: ...39 w w w g a r u d a n c z...
Page 105: ...w w w g a r u d a n c z...
Page 109: ...101 10 3 3 1006 Control System Diagram w w w g a r u d a n c z...