Boiler system
Turn on the device using the ON/OFF switch. The display will light up. If the boiler [1] is empty (at the
first installation or after running the shut down menu), the commissioning menu will automatically start
and will guide you through the filling-up sequence. If the boiler is filled, the heating element [1.3] will
be switched on by the power relay [3]. As soon as the NTC sensor [1.1] measures the set temperature,
the heating element [1.3] will be switched off. The insulation [1.5] prevents the boiler from cooling
down. The boiler is tested at an overpressure of 13 bar (1.3 MPa) constructed for working pressures of
10 bar (1.0 MPa).
Major parts
Technical data
Art.No.
Material
1. Boiler system
1.1 Litre
1000530
st.st.
1.1 Temperature sensor NTC
100 kΩ/25 °C / M12x1
1000740
st.st.
1.2 Boiler outllet
G1/4” x Ø 6 mm (2x)
st.st.
1.3 Boiler & heating element
230 V 1800 W / art.nr.
1000530
st.st.
1.4 Dry boil protection
230 V 16 A / art.nr.
1000736
st.st.
1.5 Insulation
PEC
1.6 Boiler inlet
G1/4” x Ø 8 mm (2x)
st.st.
2. Dispensing valve (3 way)
See 3.7.1 Dispensing valve
1000699
3. Power relay
24 Vdc / ~250 Vac 30 A
1004596
1
1.3
1.4
1.6
1.2
2
1.1
1.5
3