CNC Motion Setup/Testing Utility
P/N 70000634A
All rights reserved. Subject to change without notice.
23-December-05
11
ANILAM Amplifier Parameter Files
If using the ANILAM AC Brushless Servo Amplifier (refer to
Digital Brushless AC Servo Amplifier, P/N 33001279
amplifier's communications cable, P/N 33001389, is connected between
the amplifier
J1
and the CNC. All servo amplifier settings are done
digitally through the communications cable and the CNC. Parameter
settings can be sent from the CNC to the amplifier and vice versa. The
parameter settings are saved on the CNC in C:\P4T under the filename
DIGAMP-*.BK
(where * corresponds to the specific axes).
It is recommended that after making any amplifier parameter settings that
these settings be saved on the CNC for easy restore, if needed. To save
the parameter settings on the CNC:
1. Select the Axes
2. Press
Misc
(
F9
)
3. Select
Backup Amp Settings
For later restore of the saved parameter settings from the backup:
1. Select the Axes
2. Press
Misc
(
F9
)
3. Select
Restore from Backup
Balancing Servo Amplifier Outputs (F6)
Use the following procedures for:
•
•
Motion setup and testing (MST)
Setup Parameter Verification
Figure 6, Digital Brushless AC Servo Amplifier, P/N 33001279
1. At the Software Options menu, select
Setup Utility
.
2. Select
Builder Setup
.
3. Select
General Axis
.
4. Select
Digital Amplifier Settings
.
Summary of Contents for 4200T CNC
Page 1: ...www anilam com ...