The air condenser should be kept clean to ensure the appliance's perfor-
mance and efficiency, as air should freely circulate inside the appliance.
The condenser should therefore be cleaned every 30 days, using non-
metal brushes to remove all dust and dirt from condenser blades.
–
Access to the condenser is from the front.
–
Unhook the front guard, pulling it towards you.
The appliance has been tested before being put into service.
The information provided below is intended to assist in the identification and correction
of any anomalies and malfunctions which might occur during use.
The user can solve some of these problems himself, but for others specific technical
knowledge or skill is required, and so they must only be carried out by qualified staff
with recognised experience acquired in the specific sector of operation.
CLEANING THE AIR CONDENSER
FAULT
6
TROUBLESHOOTING
Fault
Remedy
Remedy
The display board does
not switch on
No power supply
Check the connection to the power mains
Blown fuse
Replace fuses (qualified technician)
Loosened connections
Check connection fitting
Compressor failure
High and Low-pressure switch on
Qualified technician required
Clicker on
Qualified technician required
Contactor failure
Qualified technician required
Compressor thermal relay on
Qualified technician required
The compressor is work-
ing but the cabinet is not
cooling
Frosted evaporator
Open the door and carry out the defrost
cycle
No coolant inside the refrigerating
system
Qualified technician required
Delivery solenoid valve failure
Qualified technician required
Condenser dirty
Clean the condenser
Evaporator fans are not
working
Fan failure or short-circuit
Qualified technician required
Door micro failure
Qualified technician required
The condenser fans do
not work
Faulty pressure switch
Qualified technician required
Faulty fan
Qualified technician required
Faulty pick-up condenser
Qualified technician required
Lack of consent from compressor
solenoid switch
Qualified technician required
Lack of evaporator de-
frosting
Incorrect defrosting programming
Check the defrosting cycle programming
Summary of Contents for B1101SU