ES
CAN
DE
US
IT
329
9702
_r
e
v
.2
.f
ID
M
English
-
52
-
Use and installation manual
The appliance must be installed and tested in full compliance with accident-prevention
regulations contained in national law and current guidelines.
Installers are to comply with any current local regulations.
–
Place the appliance onto the required working site.
–
Avoid locations with exposure to direct sunlight.
–
Do not place the appliance in hot, poorly-ventilated
rooms.
–
Leave a min. 3.94” clearance around the appliance on
the sides where air inlet and outlet are located.
Important
The appliance must be connected to FX ovens by
following the instructions in the instruction sheet supplied with KIT BE1+FX
Level the appliance by means of adjustable feet.
Important
If the appliance is not properly levelled the perform-
ance and condensate drain may be hampered.
Air-condenser units should not operate if room temperature is over 100°F. Above 89°F
maximum output is not guaranteed.
An omnipolar switch is to be installed before the appliance,
in compliance with the current regulations applied in the
country where the appliance is installed.
POSITIONING
LEVELLING
MAX ROOM TEMPERATURE
Model
Air q.ty
[cfm]
B151MU - B152MU - B151HU
650
B1101SU
2060
WIRING
Summary of Contents for B1101SU
Page 57: ......
Page 113: ......
Page 120: ...ES FR DE GB IT CT3299702_rev VII ELECTRICAL SYSTEM DIAGRAM B152MU SCHEMA ELECTRIQUE B152MU ...