II
-
CT
39
60
36
00
.fm
1)
Terminal board
2)
Left well switch
3)
Left well power on light
4)
Left well thermostat light
5)
Gas solenoid valve with ignition contact (left well)
6)
Electronic ignition devic
7)
Thermostatic control electronic circuit board (left well)
8)
Left well temperature display
9)
Left well safety thermostat
10)
Left well thermocouple
11)
Right well switch
12)
Right well power on light
13)
Right well thermostat light
14)
Gas solenoid valve with ignition contact (right well)
15)
Thermostatic control electronic circuit board (right well)
16)
Right well temperature display
17)
Right well safety thermostat
18)
Right well thermocouple
(
1
)Test point pressure
(
2
) - Nominal gas consumption
(
2.1
) - Main burner injector size
(
3
) - Pilot injector size
(
4
) -Adjusting burner primary air (see pag.18)
- ELECTRIC DIAGRAM -
N.G.C. (2)
Pilot flame
Primary areation
GAS TPP (1) Supply pressure
G.C.
Ø (2.1)
Ø (3)
Ø (4)
NGN
0.8 kPa
1.13 kPa
88 MJ/h
2.25 mm
0.40 mm
26 mm open
ULPG
2.75 kPa
2.75 kPa
88 MJ/h
1.25 mm
0.25 mm
26 mm open
IDM-39603623900.tif
240V/1N
6
1
18
10
9
5
14
17
15
16
12
11
13
7
8
3
4
2