To make the connection, connect the mains line to the
appliance's connection pipe, fitting a shut-off tap (
A
),
to allow the gas supply to be cut off when necessary.
Important
The tap (A), not supplied with the appliance,
must be installed in an easily accessible
position and its status (on or off) must be
obvious at a glance
This appliance shall be installed only by au-
thorised personnel and in accordance with
the manufacturer’s installation instruc-
tions, local gas fitting regulations, munici-
pal building codes, water supply
regulations, electrical wiring regulations,
AS 5601/AG 601 - Gas Installations and any
other statutory regulations
Important
The connection must be made by author-
ised, skilled personnel, in accordance with
the relevant legal requirements, using ap-
propriate and specified materials.
Caution - warning
Before doing any work, cut off the mains elec-
tricity supply.
Connect the appliance to the mains electricity supply
as follows.
1- If not already present, install a circuit-breaker (
A
)
with overload cutout and differential safety break-
er close to the appliance.
2 - Open the hatch (
B
).
3 - Undo the screws (
C
) to remove the guard (
D
).
4 - Connect the circuit-breaker (
A
) to the terminal
board (
E
) of the appliance as shown in the dia-
gram and in the electrical system diagram at the
back of the manual.
N.B.: use a cable with at least H05RN-F characteristics.
Important
When connecting, take care over the con-
nection of the neutral and earth lines; if
they are not connected correctly, the burn-
er does not light.
5 - Replace the lid (
D
) and retighten the screws (
C
)
on completion of the operation
GAS CONNECTION
ELECTRICAL CONNECTION
A
IDM-3960200230.tif
B
C
A
C
D
C
IDM-39603311900.tif
E