IT
GB
DE
FR
ES
- 12 -
C13960
6101.
fm
English
IT
GB
DE
FR
ES
To carry out this operation,
proceed as follows.
1 - Turn off the gas supply
tap.
2 - Pull off the knob
(A)
.
3 - Undo the screws
(B)
and
remove the control panel
(C)
.
4 - Undo the screw
(D)
of
the pressure connection.
5 - Connect the pressure
gauge
(E)
to the pres-
sure test point
(F)
.
6 - Turn the gas supply tap back on.
7 - Light the burner and turn the knob to the full
flame setting (see page 8), then check that the
pressure reading complies with the values in
the table (see back of manual)
.
8 - Switch off the burner, turn off the gas supply tap
and disconnect the pressure gauge.
9 - Restore the initial conditions after completing
the operation.
CHECKING GAS PRESSURE
The appliance has been tested before being put
into service.
The information provided below is intended to assist
in the identification and correction of any anomalies
and malfunctions which might occur during use.
The user can solve some of these problems him-
self, but for others specific technical knowledge or
skill is required, and so they must only be carried
out by qualified staff with recognised experience ac-
quired in the specific sector of operation.
FAULT
6
TROUBLESHOOTING
Faults
Causes
Remedies
Smell of gas
Occasional leak because flame
has gone out
Turn off the gas supply tap and
ventilate the room
The pilot light does not ignite
The spark ignition devices are
not working
Check that the ignition devices are in
good working order. Light by hand with
a naked light
Contact the after-sales service.
Air in pipelines due to long period
out of use
Make more attempts to light
the flame
The pilot light goes out
The thermocouple has not warmed up
enough
Make more attempts to light
the flame
The flame is yellow
Burner dirty, heat exchange pipes
clogged, condensation drips
Contact the after-sales service.
Burner control knob is stiff
Gas control valve malfunctionn
Contact the after-sales service.
Important
Important
Important
D
E
C
B
A
IDM-39606100600.tif
F