background image

N

15

Range:  

Open field (Open area without obstructions): 
•  Between the Nursery Unit and the Parent Unit:  

up to 250 metres.

•  Between the Nursery Unit and the Sensor Pad:  

up to 6 metres.

Thermometer Guidelines:  

High Temperature Alarm: 22°C  

Low Temperature Alarm: 16°C 
Power Supply: 

2 AAA alkaline batteries (not included) or 100-240 V AC / 

5V DC 0.6A Adapters for the Nursery Unit.
2 AAA rechargeable batteries and 100-240 V AC / 5V DC 

0.6A Adapters for the  Parent Unit.
1 included CR2450 3V battery (wireless Sensor Pad)
Caution: To reduce the risk of electric shock, do not 

expose this product to rain or moisture.
Danger of explosion if batteries are incorrectly 

replaced. The battery included for the Parent Unit is 

a user replaceable Li-ion rechargeable battery. Only 

use the Angelcare recommended replacement battery. 

To obtain information on replacement batteries 

please contact Angelcare customer service: www.

angelcarebaby.com or contact your local distributor. 

Instructions will be included with the replacement 

battery. Keep all batteries away from children.
Batteries:

•  DO NOT mix alkaline standard (carbon-zinc), or 

rechargeable (NI-CD, NIMH, etc.) batteries.

•  CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED 

BY AN INCORRECT TYPE

Transmission: 

Transmission between the Parent Unit and the Nursery 

Unit is made on 1.8 GHz frequency for Europe/Asia/

Africa/Australia.
Transmission between the Nursery Unit and the Sensor 

Pad is made on 2.4 GHz frequency for Europe/Asia/

Africa/Australia
Maximum RF Power Transmitted:

• 24dBm (250mW) between Nursery Unit and Parent Unit
• 4dBm (2.5mW) between Nursery Unit and Sensor Pad
RF Channel no. between Nursery Unit and Parent Unit: 5
RF Channel no. between Nursery Unit and Sensor Pad: 79
Hereby, Angelcare Monitors Inc., declares that this Baby 

Monitor is in compliance with Directive 2014/53/EU. The 

full text of the EU declaration of conformity is available at 

the following internet address: https://angelcarebaby.

com/declaration-of-conformity
RF Exposure - 
This device is designed and manufactured 

to comply with Radio Frequency (RF) radiation exposure 

limits for EU for an uncontrolled environment. To maintain 

the compliance, human exposure to the nursery unit shall 

not be less than 20 cm during normal operation.

PROTECT THE ENVIRONMENT

The wheelie bin symbols mean that according to local 

laws and regulations your product and/or its battery 

shall be disposed of separately from household 

waste. When the product/battery reaches its end of 

life take it to a collection point designated by local 

authorities. The separate disposal and recycling will 

help conserve natural resources and protect human 

health and the environment. Refer to User’s Guide for 

removal of batteries.

ErP Compliance

USE ONLY THE FOLLOWING ANGELCARE® BRAND 

POWER SUPPLY MODEL NUMBERS:
EUROPEAN UNION (INCLUDING GERMANY) – 

K05S050060G
UK - K05S050060B

TECHNICAL SPECIFICATIONS

See product for compliance marks specific to this device.

15

CFO3B_ANGE_Manuel_AC127_ROW.indd   15

19-02-05   08:54

Summary of Contents for AC127

Page 1: ...product WARNING Model AC127 Baby Movement Monitor with Sound OWNER S MANUAL IMPORTANT INTENDED USE This product is NOT intended and should NOT be used to prevent Sudden Infant Death Syndrome SIDS This product is NOT intended to diagnose treat mitigate cure or prevent any disease or condition This is a product to monitor the movement of healthy babies and is not a substitute for parental care CFO3B...

Page 2: ...E Clean wipe with a dry lint free cloth 13 The Sensor Pad is not suitable for use above age 24 months 14 This product cannot replace responsible adult supervision This product is designed to aid in the monitoring of your child When using the monitor you must still 2 This baby monitor is compliant with all relevant standards regarding electromagnetic fields and is when handled as described in the U...

Page 3: ...on 29 This product contains a Button Cell Battery and if swallowed can cause internal chemical burns in as little as two hours and lead to death Dispose of used batteries immediately Keep new and used batteries away from children If you think batteries might have been swallowed or placed inside any of the body seek medical attention 30 The Button Cell Battery represents a small part and a choking ...

Page 4: ...electric shock or fire 42 Unplug this appliance during lightning storms or when not used for long periods of time 43 Servicing DO NOT attempt to service this product yourself as opening or removing covers except battery door may expose you to dangerous voltage or other hazards Power Supply see Technical Specification within this guide 44 Overloading DO NOT overload wall outlets extension cords or ...

Page 5: ... detected for 20 seconds 1 2 1 Remove the battery cover and insert the battery face with face up 2 Replace the battery cover align 2 dots and click to secure Correct positioning for slatted base 3 3 Remove the mattress from the cot place Sensor Pad Angelcare logo side up on base in approximate centre of mattress It should be centred on the hardboard if your cot requires a hardboard support see IMP...

Page 6: ...es and not memory foam partial or full hollow frame construction mattresses and water beds Please consult Angelcare if unsure of mattress compatibility The hardboard maintains a constant pressure on the Sensor Pad enabling it to detect the baby s movements even when the baby is at the edges of the cot IMPORTANT 3 SETTING UP THE NURSERY UNIT Note The alkaline batteries not included are a back up po...

Page 7: ...justed accordingly 3 The Sensor Pad will detect false movements if you are touching the cot 4 The monitor will produce a Rouse alarm single beep tone designed to stir baby if no movement has been detected for 15 seconds If no further movement is detected the main alarm will sound at 20 seconds a series of continuous beeps SENSOR PAD FOUR CORNER TEST 1 Place the Sensor Pad at the approximate centre...

Page 8: ...you to turn OFF LED ring light Pager press hold Allows you to locate the Parent Unit 5 Speaker 6 Power ON OFF 7 Micro USB port 8 Movement Sensor Pad sensitivity switch 9 Pause Movement Sensor Pad 10 Battery compartment 1 2 3 FRONT SIDE 10 4 6 5 7 8 9 REAR SIDE PARENT UNIT 1 Movement detection indicator TIC 2 Power ON OFF 3 Menu press and hold Exit menu 4 Confirm selection or change function Pause ...

Page 9: ...ction If movement detection is activated allows you to hear a Tic sound every 5 seconds Activate Deactivate sound nursery transmission Allows you to use your monitor for movement detection only Set VOX function Sound Activated VOX ON Means that it will transmit sounds only when it detects them based on the setting of the sensitivity level To save power after 10 seconds the sound transmission will ...

Page 10: ...vement alarm If NO movement is detected after 15 seconds you will hear a single TIC pre alarm sound from the Nursery Unit this is the Rouse Alarm If after a further 5 seconds there is still NO movement detected both the Parent Unit and Nursery Unit speakers will emit loud consecutive beeps this is the Movement Alarm Sensor Pad Icon and sound level bar on Parent Unit will flash 2 Out of range alarm...

Page 11: ...n simply press any button of the Parent Unit 7 TROUBLESHOOTING TAKING CARE OF YOUR RECHARGEABLE BATTERY Ensure that you fully charge your batteries for 10 hours before their first use To maintain maximum battery life it is recommended that you fully discharge your batteries periodically Battery performance can be diminished by leaving the batteries constantly charging If your Parent Unit is not in...

Page 12: ... seconds on the Power ON OFF button Power Indication of the Nursery Unit will turn green 4 Press and hold the Pause button on the Nursery Unit for 3 seconds The Sensor Pad indicator Light of the Nursery Unit will flash blue BLUE 3 4 The reconnection should be completed within 30 seconds The reconnection is successful when Nursery Unit sounds a confirmation tone MOVEMENT SENSOR PAD NO ALARM Sources...

Page 13: ...ctrical outlets Check the batteries in both units replace or recharge them if necessary Bring the Parent Unit closer to the Nursery Unit STATIC DISTORTION INTERFERENCES FROM OTHER MONITORS WIRELESS PHONES WALKIE TALKIES ETC Rotate the Parent Unit or move it away from source of interference FEEDBACK LOUD NOISES EMITTED FROM THE PARENT UNIT Move units further apart at least 3 metres apart Decrease v...

Page 14: ...ntal or consequential damages with regard to this product The warranty also excludes any liability other than what is stated above No other warranty is given This warranty does not cover products and accessories which are not Angelcare branded or any problems that result from usage that is not in accordance with product instructions failure to follow the product instructions or problems caused by ...

Page 15: ...t and the Sensor Pad is made on 2 4 GHz frequency for Europe Asia Africa Australia Maximum RF Power Transmitted 24dBm 250mW between Nursery Unit and Parent Unit 4dBm 2 5mW between Nursery Unit and Sensor Pad RF Channel no between Nursery Unit and Parent Unit 5 RF Channel no between Nursery Unit and Sensor Pad 79 Hereby Angelcare Monitors Inc declares that this Baby Monitor is in compliance with Di...

Page 16: ...tely satisfied or have any questions please contact your distributor before returning this product United States and Canada Please contact us at info angelcarebaby com Other countries Find your local distributor by visiting our website angelcarebaby com distributors TO LEARN MORE To learn more watch the set up videos and other functionalities on our website https angelcare zendesk com hc Angelcare...

Reviews: