E
N
11
NURSERY UNIT
1
Power On/Off & Low Battery Light Indicator
Steady green: Monitor is activated
Flashing green: Nursery unit is using the back-up batteries
Flashing yellow: Nursery Unit batteries are low
2
Movement Sensor Pad & Temperature Indicator
Flashing red: No movement is detected
• Both the Parent Unit and Nursery Unit speakers will emit loud
continuous beeps - this is the Movement Alarm
Flashing white: Monitor is paused
• Both the Parent Unit and Nursery Unit emit a single beep every
20 seconds
Flashing light blue: Loss of connectivity between the Nursery unit
and the Sensor Pad
• Both the Parent Unit and Nursery Unit speakers will emit loud
continuous beeps
Steady Red: Room temperature is too hot
• The Parent Unit will emit 3 consecutive beeps every 5 seconds
Steady Blue: Room temperature is too cold
• The Parent Unit will emit 3 consecutive beeps every 5 seconds
Steady White: Room temperature is good
1
2
Note:
Press any key of the Parent Unit to stop alarm or Press the Pause Sensor Pad button of the
Nursery Unit
In the case of a Sensor Pad alarm, the monitor will Pause the Sensor Pad. In Pause mode, the
movement detection feature is disabled. To reactivate the movement detection, simply press
any button of the Parent Unit
7- TROUBLESHOOTING
TAKING CARE OF YOUR RECHARGEABLE BATTERY
• Ensure that you fully charge your batteries for 10 hours before their first use.
• To maintain maximum battery life it is recommended that you fully discharge your batteries periodically. Battery
performance can be diminished by leaving the batteries constantly charging. If your Parent Unit is not in use,
please turn it off.
• Inadequate battery power can impair the performance of your monitor. If you are not happy with the performance
of your Parent Unit please replace the rechargeable batteries (2 x NiMH Rechargeable Batteries).
• It is advisable to change the batteries every 6 months.
LOSS OF CONNECTIVITY BETWEEN THE PARENT UNIT AND THE NURSERY UNIT
• In the case of loss of connectivity, the first step is to bring the Parent Unit and Nursery Unit closer together and
make sure that both units are ON to restore the connection. If there is still no connection and no out-of-range
warning after the above has been done, then and only then should the re-connection procedure below be done.
1. Turn both Units OFF
2. Turn the Nursery Unit ON
3. Press 4 consecutive times the Power ON/OFF button on the Nursery Unit
The Sensor Pad Indicator Light on the Nursery Unit will flash
quickly in green (indicates Nursery Unit is in linking mode)
GREEN
3
CFO3B_ANGE_Manuel_AC127_ROW.indd 11
19-02-05 08:54