Anets SLG100 Installation And Operation Manual Download Page 7

SLG I&O Series

 

Caution

 

Ensure that your ventilation system does not cause a down draft at the appliance’s flue 

opening. A down draft will not allow the appliance to exhaust properly and will cause 

overheating, which may cause permanent damage. NEVER point a fan or similar device at 

or toward the flue opening of this appliance. Damage caused by down drafts will not be 

covered by the warranty. NEVER allow anything to obstruct the flow of combustibles or 

ventilation exiting the appliance. NEVER place anything on top of the flue area, or block 

the flue in any way.

 

 

Notice

 

NEVER connect the ventilation blower or hood directly to the flue of this appliance. The 

resulting increased flow of air through the combustion system will cause improper 

operation, poor temperature recovery, poor ignition and could extinguish the pilot. 

 
 

2.6 Initial 

Adjustments 

 
After your appliance has been properly installed as described in the installation section of this manual, it will 
need to be adjusted to ensure that it will perform as designed. These adjustments must be performed by a 
qualified person. To perform these adjustments the following tools will be needed: 
 
•  Manometer   

•  Digital Thermometer (Temperature Probe) 

•  DC Millivolt Meter 

•  DC Milliameter 

 
Before you begin filling and adjusting the appliance, perform the following visual checks: 
 

a. 

After the appliance is in its permanent location, 
check the levelness. Any additional leveling that 
is necessary can be performed as previously 
described. 

 
b. 

Check the temperature probe and high limit bulb 
(in the tank) to ensure that the mounting screws are tight. 

 

c. 

Review the installation portion of this manual and ensure that all steps have been followed and 
executed properly. 

 

2.7  Burner Ignition Systems 

 

Caution 

Before proceeding any further, fill the tank with WATER. Water is used for the installation 

adjustments because the temperature will never exceed 212°F (100°C), thereby allowing 

plenty of adjustment time. Never let the water level go below the MIN LEVEL mark stamped 

on the tank. 

 

Warning 

During operation there is an open flame inside this appliance. The unit may get hot 

enough to set near by materials on fire. Keep the area around the appliance free from 

combustibles. 

Ensure that these parts are tight. 

Summary of Contents for SLG100

Page 1: ...n this manual for the life of the equipment Model __________________________ Serial __________________________ Date Purchased ___________________ Installation and Operation Manual Covering Model Serie...

Page 2: ...n additional restraining cable must be connected at all times when the appliance is in use WARNING An appliance equipped with casters and a flexible gas line must be connected to the gas supply with a...

Page 3: ...Burner System Adjustment 9 3 3 Initial Cleaning 9 4 Filling the Tank 10 4 1 Filling the tank with liquid shortening oil 10 4 2 Filling the tank with solid shortening oil 11 5 Operating Instructions 11...

Page 4: ...sly inhibit this appliances ability to effect proper combustion WARNING This appliance must be installed with the legs provided by the manufacturer WARNING Do not install legs or perform leveling proc...

Page 5: ...e is now ready to be installed The appliance must be installed by a qualified professional A qualified professional will ensure that the installation is safe and meets local building and fire codes an...

Page 6: ...he Standard for Gas Installations AS 5601 latest edition This connection should include a quick disconnect device that complies with the Standard for Limited Flexibility Connectors AS4631 latest editi...

Page 7: ...designed These adjustments must be performed by a qualified person To perform these adjustments the following tools will be needed Manometer Digital Thermometer Temperature Probe DC Millivolt Meter DC...

Page 8: ...manual pilots refer to the following instructions Perform this procedure once the pilot is lit NOTE This procedure requires a DC millivolt meter set to a scale of 0 1000 mV Using test leads with shar...

Page 9: ...te supply line installation which will cause poor performance of all appliances during peak usage c The installed pressure gauge should be the same 0 1 w c 025 kPa as that marked on the data plate on...

Page 10: ...e water as any residual water will cause hot shortening oil to splatter out of the appliance Notice Mild steel tanks must be wiped down coated thoroughly with shortening oil to keep the tank from rust...

Page 11: ...his appliance follow the preparation instructions from the food manufacturer Using the best shortening oil makes the best fried foods The best shortening oil will last longer than lower grade shorteni...

Page 12: ...aning Your appliance should be cleaned every day to maintain peak performance proper sanitation and appearance Perform the following procedures daily a Wipe up any shortening oil that spills onto the...

Page 13: ...in the shortening oil approximately one inch above the temperature sensor b Light the pilot as described in this manual set the thermostat to 325 F 163 C and allow the shortening oil to come up to tem...

Page 14: ...draining and filling procedure Warning At operating temperatures the shortening oil in the appliance is VERY HOT and can cause severe burns Do not let the hot shortening oil touch your skin or clothi...

Page 15: ...tion causes the oil to smoke badly even if the temperature is lowered to 190 C again High oil temperatures give you no advantage cost you money and increase the fire danger TEMPERATURA DELL OLIO Mante...

Page 16: ...e pilot gas line YES NO Is high limit switch open YES Will high limit switch reset YES Reset switch and light pilot Contact a qualified service technician NO NO Does pilot go out when the temperature...

Page 17: ...LP SLG40 Gas Valve PP11001 PP11002 SLG100 Gas Valve PP10955 PP10956 Thermocouple P5047540 Thermocouple P5047540 Thermostat P5047590 Thermostat P5047590 Thermostat Knob PP10539 Thermostat Knob PP10539...

Page 18: ...wingnuts and burner retainer plate 5 Remove burner This will make removing the pilot on SLG40 or runner tube on SLG100 easier 6 Loosen the brass fitting on the gas valve holding the pilot line 7 Remov...

Page 19: ...SLG I O Series 19...

Page 20: ...roblems with or questions about your order please contact the Anetsberger Factory at 001 603 225 6684 World Wide In the event of problems with or questions about your equipment please contact the Anet...

Reviews: