SLG I&O Series
7
Caution
Ensure that your ventilation system does not cause a down draft at the appliance’s flue
opening. A down draft will not allow the appliance to exhaust properly and will cause
overheating, which may cause permanent damage. NEVER point a fan or similar device at
or toward the flue opening of this appliance. Damage caused by down drafts will not be
covered by the warranty. NEVER allow anything to obstruct the flow of combustibles or
ventilation exiting the appliance. NEVER place anything on top of the flue area, or block
the flue in any way.
Notice
NEVER connect the ventilation blower or hood directly to the flue of this appliance. The
resulting increased flow of air through the combustion system will cause improper
operation, poor temperature recovery, poor ignition and could extinguish the pilot.
2.6 Initial
Adjustments
After your appliance has been properly installed as described in the installation section of this manual, it will
need to be adjusted to ensure that it will perform as designed. These adjustments must be performed by a
qualified person. To perform these adjustments the following tools will be needed:
• Manometer
• Digital Thermometer (Temperature Probe)
• DC Millivolt Meter
• DC Milliameter
Before you begin filling and adjusting the appliance, perform the following visual checks:
a.
After the appliance is in its permanent location,
check the levelness. Any additional leveling that
is necessary can be performed as previously
described.
b.
Check the temperature probe and high limit bulb
(in the tank) to ensure that the mounting screws are tight.
c.
Review the installation portion of this manual and ensure that all steps have been followed and
executed properly.
2.7 Burner Ignition Systems
Caution
Before proceeding any further, fill the tank with WATER. Water is used for the installation
adjustments because the temperature will never exceed 212°F (100°C), thereby allowing
plenty of adjustment time. Never let the water level go below the MIN LEVEL mark stamped
on the tank.
Warning
During operation there is an open flame inside this appliance. The unit may get hot
enough to set near by materials on fire. Keep the area around the appliance free from
combustibles.
Ensure that these parts are tight.
Summary of Contents for SLG100
Page 19: ...SLG I O Series 19...