10
-
4.5
Cleaning after painting job is finished
WARNING
(
1
) After painting job is finished, be sure to fully release air pressure and fluid pressure and turn off
electrostatic controller (E-SC12BH : option) or electrostatic controller of multi-gun control system
(
E-MC12
:
option
)
(2)
Before cleaning fluid passage
(
spraying thinner
)
, be sure to turn off electrostatic controller
(
E-SC12BH
:
option
)
or electrostatic controller of multi-gun control system
(
E-MC12
:
option
)
or
electric source of lumped operating panel to avoid charge. If not, it can cause ignition and great
danger
Job
−
1
Clean fluid passage
(
spray thinner
)
Spray till cleaning thinner becomes transparent.
Job
−
2
Clean atomizing head
Remove and clean air cap cover and air cap
(
As for details, refer to
6
.
「
Disassembly and assembly
」
on page 17
)
Job
−
3
Clean electrostatic air hand gun and low voltage cable
In order to use electrostatic gun for a long time, wipe off surface of electrostatic gun and low voltage cable
with soft cloth soaked with cleaning thinner and cleaning brush (to clean surface). After cleaning is
finished, be sure to blow surface of gun and low voltage cable with air and dry up attached thinner.
Air cap cover
Air cap
By hand
By hand
OK if it becomes transparent
Summary of Contents for E-M20 Series
Page 1: ...E M25 E M20...
Page 2: ......
Page 3: ...1 1 1 E SC12 A 10 A...
Page 4: ...E SC12 10cm P 1 1 OFF E SC24...
Page 5: ...B A 10 5 10 8 JIS T 8103 JIS T 8118 OFF...
Page 6: ...P 11 3 P 9 10 P 5...
Page 7: ...1 1 2 3 4 5 6 7 8 9...
Page 9: ...3 2 E M25 E M20...
Page 10: ...4 E M25 E M20 G3 8 AC 12V G1 4 G3 8 AC 12V G1 4...
Page 11: ...5 4 cm cm 50cm...
Page 15: ...9 1 E SC12BH 200 300mm...
Page 16: ...10 E SC12 OFF E SC12 OFF 1 2 P 17 3...
Page 17: ...11 1...
Page 18: ...12 1 E SC12BH 1 P 10 11 No 8 1 P 26 8 1 P26 8 2 P 27 5 1 2 No 1 P12 4 1 P 5 No...
Page 21: ...15 E SC12BH 1 2 DC V 60kV MAX ON DC 11 5 12 5V EBC 12S7 E SC12BH...
Page 22: ...16 1 E SC12BH 1 1 2 3 4 1 2 1...
Page 23: ...17 2 2 1 2 M2X0 4 1...
Page 24: ...18 2 3 1 2 30 1 3...
Page 25: ...19 2 3 1 2 20...
Page 26: ...20 1 2 mm...
Page 27: ...21 E M25 2 E M20 2...
Page 28: ...22...
Page 31: ...25 No 1...
Page 32: ...26 No 30M cm E SC BH...
Page 33: ...27 No...