![Anest Iwata DVSL-100C Instruction Manual Download Page 29](http://html.mh-extra.com/html/anest-iwata/dvsl-100c/dvsl-100c_instruction-manual_2943112029.webp)
-27-
8. Specifications
8.1 Specifications
Model
DVSL
DVSL
DVSL
DVSL-
--
-100C
100C
100C
100C
Displacement
50Hz
100
L/min
60Hz
120
U l t i m a t e p r e s s u r e P a
≦50
Max. inlet pressure
Atmospheric pressure
Ambient operating
temperature
5℃~40℃
Type
Single-phase squirrel cage induction motor
Totally-enclosed , 2-pole
B class insulation,
・
Multiplex voltage, IP42
Output
kW
0.3/0.3 (50Hz/60Hz)
Voltage
V
100
115
200
230
50Hz
3.2
-
1.6
2.0
Rated current
A
60Hz
3.7
3.4
1.6
1.7
50Hz
2940
-
2938
2950
M
o
to
r
Revolution
min
-1
{rpm}
60Hz
3540
3550
3534
3550
Noise level 1m dB(A)
(With air-flush ON)
≦62
(≦65)
Inlet connection
NW25 [Internal screw size : Rc3/8]
Outlet connection
NW16 [With exhaust valve]
Dimensions mm
W×L×H
358 210 215
Mass
kg
15
Cooling system
Air-cooled
Others
air-flush
Note 1
:
Pumping speed and ultimate pressure remain the same during air-flush operation and standard
operation.
Note 2
:
Noise level is measured at ultimate pressure in an anechoic room.
Note 3
:
Vapor handling is less than 100g/day during air-flush operation. Air-flush volume is 5L/min.
Air-flush is OFF (closed) when pump is delivered.
Note 4
:
It is wired to 100V when delivered to you.
Note 5
: